Presentation is loading. Please wait.

Presentation is loading. Please wait.

Fresenius Medical Care Peritoneal Dialysis Connections Baxter to stay safe Connection.

Similar presentations


Presentation on theme: "Fresenius Medical Care Peritoneal Dialysis Connections Baxter to stay safe Connection."— Presentation transcript:

1 Fresenius Medical Care Peritoneal Dialysis Connections Baxter to stay safe Connection

2 Connections using Fresenius Medical Care products This inservice is not intended to replace the advice or training from your physician. Refer to the Instructions For Use (IFU) for detailed device description, instructions, contraindications, warnings, and precautions. Fresenius Medical Care, DEL-CLAMP, Stay●Safe, Safe-Lock, DELFLEX and FREEDOM are trademarks of Fresenius Medical Care Holdings Inc. or its affiliated companies. All other trademarks are the property of their respective owners.

3 Fresenius Products Baxter is a trademark of Baxter International Inc. or its affiliates. Instructions on how to use Baxter products were reproduced from the manufacturer’s literature and were current at the time of print. Instructions are included for the patient's convenience but Fresenius Medical Care North America does not specifically endorse the use of these products or assume any liability related to their use. Should there be any differences between the instructions listed in this manual and the instructions for use provided with the medical devices referenced, the instructions provided with the medical device should be taken as accurate."

4 Connections using Fresenius Medical Care products Note: for clarity the model is shown not wearing personal protective equipment (PPE). Follow your facility’s policies and procedures for use of personal protective equipment. It is vital to maintain sterility of the connectors during connection procedures.

5 Baxter patient to stay safe system Baxter PD patient stay safe System stay safe Extension Set with Luer-Lock patient connector A stay safe Extension Set with Luer-Lock patient connector will allow the patient with a Baxter PD system to use stay safe supplies while in the hospital.

6 Baxter patient to stay safe system Gather supplies stay safe solution set and related supplies for transfer set connection and exchange procedure. stay safe Extension Set with Luer-Lock patient connector 12 inch (P/N # ) Or 18 inch (P/N # )

7 Baxter patient to stay safe system 1.Remove the blue sterility protector from the end of the Fresenius stay safe Extension Set. 2.Remove the mini-cap from the Baxter patient extension set. 3. Attach the Fresenius stay safe Extension Set to the end of the Baxter extension set. Proceed with the stay safe CAPD or APD exchange. 1 ent extension setent extension set Baxter Extension Set stay safe Extension Set 3 2

8 Titanium luer lock adapter to stay safe system stay safe solution set and related supplies for transfer set connection and exchange procedure. stay safe Extension Set with Luer-Lock patient connector 12 inch (P/N # ) Or 18 inch (P/N # ) Remove the blue sterility protector from the end of the Fresenius stay● safe extension set and attach to the luer lock catheter adapter.

9 DISCHARGE INSTRUCTIONS FOR ALL CONNECTIONS The patient should return to his/her home or clinic with the additional extension in place. This practice will allow the patient to return home and resume dialysis without interruption. Instruct the patient to remove any adaptors added to their extension set at the beginning of the next exchange or as directed by the PD clinic nurse.

10 Select the catheter or transfer set used by the patient. Select the System the Hospital Uses Catheter or Transfer Set or or With Luer- Lock Adapter Titanium With Safe- Lock Adapter With Baxter Transfer Set With Fresenius Safe-Lock transfer Set With Fresenius Stay-Safe Transfer Set Hospital Uses Baxter Supplies Add Baxter Transfer Set 5C4484 Add FMC Universal Connector or pre-filled No Change Needed Add FMC Convertible Adapter and Baxter 5C4484 Add Stay●Safe Luer Lock Adapter 4” Hospital Uses Fresenius (FMC) Safe- Lock Supplies Add Safe-Lock Transfer Set with Luer Lock Adapter No Change Needed OR Add a FMC Safe- Lock Transfer Set with a Safe-Lock Adapter Add Convertible Extension No Change Needed Add 4” Stay●Safe Safe-Lock Adapter Hospital Uses FMC Stay-Safe Supplies Add Stay● Safe Extension Set with Luer lock Patient Connector Add Stay● Safe Extension Set with Safe lock Patient Connector Add Stay● Safe Luer Lock Adapter and a Baxter Transfer Set 5C4484 Add Stay● Safe Extension set with Safe-Lock Patient connector No Change Needed Choose the type of catheter or transfer set and the type of system utilized. Look down the column and across the row to the adapter needed. Click on the icon in the box to take you to the procedure

11 Please contact your Fresenius Clinical Sales Representative at if you have questions regarding the use of a Fresenius PD system or adapter.

12 CD Available through Customer Service (P/N # )