Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Similar presentations


Presentation on theme: "Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00."— Presentation transcript:

1 Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00

2 Security Systems BU Communication Systems ST/SEU-CO 2 DCN SA PO CCE 01.Nov.06 Central Control Unit (Com - port 1) LBB3500/05  9-pin Sub-D connector RS 232 for: Terminal mode Factory testing Diagnostics OR Camera Control 1

3 Security Systems BU Communication Systems ST/SEU-CO 3 DCN SA PO CCE 01.Nov.06 CCU Trunk Communication Board (TCB-4) 1 Jumper X14 for service only 2 S14 DIP- switches 1 – 8 Com-port settings 3 S10 Push- button switch to reset the Central Control Unit during servicing. 4 Three LEDs (left to right) green/ yellow/ red. Normally the green/ yellow LEDs flash in sequence, indicating the software is running. Red LED illuminates during system reset. 5 S9 DIP- switches 1 – 8 System modes 6 Yellow LED indicates Digital Signal Processing (DSP) software is running. 7 Connector for multi- trunk board (used only in the multi- CCU) 8 Sockets for inserting flash EPROM (even) 9 Sockets for inserting flash EPROM (odd) Upgrade Kit

4 Security Systems BU Communication Systems ST/SEU-CO 4 DCN SA PO CCE 01.Nov.06 CCU Trunk Communication Board (TCB-4) 10 SRAM back- up battery 3.6 V (life- time 5 years min.) 11 Jumper X13 Battery back up 12 Fuse 3.15 amp (delayed) 13 Connector for multi- trunk board (used only in the multi- CCU) 14 Serial RS232 Port 1 15 Serial RS232 Port 2 Upgrade Kit

5 Security Systems BU Communication Systems ST/SEU-CO 5 DCN SA PO CCE 01.Nov.06 Central Control Unit (Com - port 1) LBB3500/05 CCU Protocol and Serial Port settings - Protocol based for using Allegiant Video Switchers. For location of DIP- switches see; Table 4.5 and 4.6 LBB 3500/ 05 Port 1 for Camera Control In a single (stand- alone) CCU system only one COM- port (Port 1) is available: Default settings are; 8 data bits No parity check 1 Stop bit Installation The maximum cable length between the CCU and the ‘Allegiant Video Switcher’ should not exceed 5 m (16.4 ft). Where longer distances are required an ‘current-loop interface unit’ should be used to ensure correct transmission. I&O Manual

6 Security Systems BU Communication Systems ST/SEU-CO 6 DCN SA PO CCE 01.Nov.06 TCB-4 DIP Switch Settings (default) I&O Manual

7 Security Systems BU Communication Systems ST/SEU-CO 7 DCN SA PO CCE 01.Nov.06 Central Control Unit (Audio I/O)LBB3500/05 1. Asymmetrical Recorder In- & Outputs 2. 2 Asymmetrical line input connectors 3. Symmetrical or 2 Asymmetrical line outputs 1 2 3

8 Security Systems BU Communication Systems ST/SEU-CO 8 DCN SA PO CCE 01.Nov.06 Central Control Unit (Audio I/O)LBB3500/05 1. Tape/cassette recorder input and output (Cinch-type) Tape In Asym.nom. -33 dBVmax. -3 dBV Tape Out Asym. nom. -33 dBV max. -3 dBV 2. 2 Asymmetrical line input connectors (Cinch-type) Line In Asym.nom. -18 dBVmax. +12 dBV 3. Symmetrical/Asymmetrical line output connectors (Cinch-type) Line Out Sym.nom. -12 dBVmax. +18 dBV Line Out Asymnom. -18 dBVmax. +12 dBV

9 Security Systems BU Communication Systems ST/SEU-CO 9 DCN SA PO CCE 01.Nov Trunk Central Control Unit LBB3500/05 (Trunk Outlets) 1. Red LED overload indicators 2. Trunk outlet used for loop-through of the trunk-line-cable

10 Security Systems BU Communication Systems ST/SEU-CO 10 DCN SA PO CCE 01.Nov.06 Trunk outlets For loop-through of the DCN trunk-line without regenerating the digital signal. Power handling capacity maximum: - 60 PCF per outlet - 90 PCF total for the three outlets of the CCU. PCF =  60 max. PCF =  90 max. Central Control Unit LBB3500/05 (Trunk Outlets)

11 Security Systems BU Communication Systems ST/SEU-CO 11 DCN SA PO CCE 01.Nov Mains socket with built-in fuse Nominal Mains voltage Mains fuse Power Consumption 220, 230, 240 V AC. T- 2A (slow blow)175 W 105, 115 V, 125 V AC. T- 4A (slow blow) Warning: All units must be powered via an earthed mains outlet V-T4A/230V-T2A Central Control Unit LBB3500/05 I&O Manual

12 Security Systems BU Communication Systems ST/SEU-CO 12 DCN SA PO CCE 01.Nov.06 Extension Power Supply LBB4106/x Rear view 1. Trunk line cable 2. Overload indicators 3. Trunk outlets 4. Mains socket

13 Security Systems BU Communication Systems ST/SEU-CO 13 DCN SA PO CCE 01.Nov.06 Extension Power Supply LBB4106/x0 (Trunk outlet / Tap-off ’s) Trunk Tap-off 1.Red LED overload indicators 2.Trunk outlet used for loop-through of the trunk-line-cable 3.Tap-off outlets are used for trunk-cable splitting

14 Security Systems BU Communication Systems ST/SEU-CO 14 DCN SA PO CCE 01.Nov.06 Extension Power Supply LBB4106/x0 (Trunk outlet / Tap-off ’s) Trunk outlet For loop-through of the DCN trunk-line without regenerating the digital signal. Power handling capacity maximum: - 60 PCF per outlet PCF total for the three outlets of the EPS. Tap- offs For Trunk-cable splitting with regenerating the digital signal. Power handling capacity maximum - 60 PCF per outlet PCF total for the three outlets of the EPS. PCF =  60 max. PCF =  180 max.

15 Security Systems BU Communication Systems ST/SEU-CO 15 DCN SA PO CCE 01.Nov Mains socket with built-in fuse Nominal Mains voltage Mains fuse Power Consumption 220, 230, 240 V AC. T- 4A (slow blow)350 W 105, 115 V, 125 V AC. T- 5A (slow blow) Warning: All units must be powered via an earthed mains outlet V-T4A/230V-T2A Extension Power Supply LBB4106/x0 I&O Manual

16 Security Systems BU Communication Systems ST/SEU-CO 16 DCN SA PO CCE 01.Nov.06 Audio Media Interface LBB3508/ Rear view 1. Cinch Audio output sockets 2. XLR Audio output sockets 3. Trunk line cable 4. Overload indicators 5. Trunk outlets 6. Mains socket

17 Security Systems BU Communication Systems ST/SEU-CO 17 DCN SA PO CCE 01.Nov.06 Audio Media Interface LBB3508/00 (Audio outputs) 1 2 Output 1 Output 2 Output 3 Output Asymmetrical Audio output connectors (Cinch-type) 2. 4 Symmetrical (transformer balanced) Audio output sockets (3-pin XLR)

18 Security Systems BU Communication Systems ST/SEU-CO 18 DCN SA PO CCE 01.Nov.06 Audio Media Interface LBB3508/00 (Audio outputs Levels)  4 Asymmetrical audio outputNom. Max.. Interpreter floor & language-10 dBV- 10 dBV Multiple floor and line output -19 dBV +11 dBV Delegate loudspeaker channel -10 dBV+ 2 dBV  4 Symmetrical Audio outputNom. Max.. Interpreter floor & language +1 dBV+ 1 dBV Multiple floor and line output - 8 dBV+22 dBV Delegate loudspeaker channel+1 dBV+13 dBV

19 Security Systems BU Communication Systems ST/SEU-CO 19 DCN SA PO CCE 01.Nov.06 Audio Media Interface LBB3508/00 (Trunk outlet / Tap-off ’s) Trunk Tap-off 1.Red LED overload indicators 2.Trunk outlet used for loop-through of the trunk-line-cable 3.Tap-off outlets are used for trunk-cable splitting

20 Security Systems BU Communication Systems ST/SEU-CO 20 DCN SA PO CCE 01.Nov.06 Audio Media Interface LBB3508/00 (Audio outputs) Trunk outlet For loop-through of the DCN trunk-line without regenerating the digital signal. Power handling capacity maximum: - 60 PCF per outlet - 90 PCF total for the three outlets of the AMI. Tap- offs For Trunk-cable splitting with regenerating the digital signal. Power handling capacity maximum - 60 PCF per outlet - 90 PCF total for the three outlets of the AMI. PCF =  90 max. PCF =  60 max.

21 Security Systems BU Communication Systems ST/SEU-CO 21 DCN SA PO CCE 01.Nov Mains socket with built-in fuse Nominal Mains voltage Mains fuse Power Consumption 220, 230, 240 V AC. T- 2A (slow blow)175 W 105, 115 V, 125 V AC. T- 4A (slow blow) Warning: All units must be powered via an earthed mains outlet V-T4A/230V-T2A Audio Media Interface LBB3508/00 I&O Manual

22 Security Systems BU Communication Systems ST/SEU-CO 22 DCN SA PO CCE 01.Nov.06 Central Control Equipment End of section  Robert Bosch GmbH All rights are reserved. Reproduction or passing on to third parties in whole or in parts is prohibited without the written consent of the copyright owner.


Download ppt "Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00."