Presentation is loading. Please wait.

Presentation is loading. Please wait.

Radiographic Recognition of Dental Implants as an Aid to Identifying the Deceased Nattawut Rodchom No 51312310.

Similar presentations


Presentation on theme: "Radiographic Recognition of Dental Implants as an Aid to Identifying the Deceased Nattawut Rodchom No 51312310."— Presentation transcript:

1 Radiographic Recognition of Dental Implants as an Aid to Identifying the Deceased Nattawut Rodchom No 51312310

2 Radiographic Recognition of Dental Implants as an Aid to Identifying the Deceased

3 Dental Implant 1.Fixture 2.Abutment 3.Crown

4 Radiographic

5 review 1992 Sewerin = indentified the influence of various features of implant 2006 Michelinakis = developed computer software to assist in the indentification of implant

6 Material and Methods  Implant type  Radiograph film = Nikon 2000 camera (Tokyo,Japan)  Type of radiograph = mouth  200 radiograph images

7

8 Material and Methods Implant Recognition System (IRS) inter-examiner / intra- examiner The McNemar’s test

9 Result TABLE 1—Summary of the number of correct implant identificationradiographic images at each assessment. Examiner 1 Examiner 2 First assessment without IRS 111 (55.5%) 77 (38.5%) Second assessment without IRS 119 (59.5%) 80 (40%) First assessment with IRS 131 (65.5%) 86 (43%) Second assessment with IRS 123 (61.5%) 80 (40%)

10 TABLE 2—McNemar’s tests results Test No. Test McNemar’s Statistic Freedom Pr > S Significance 1 EX1-IRS 2.0 1 0.16 NO 1 st vs 2 nd 2 EX1+IRS 3.6 1 0.06 NO 1 st vs 2 nd 3 EX2 –IRS 0.2 1 0.64 NO 1 st vs 2 nd 4 EX2 +IRS 1.1 1 0.30 NO 1 st vs 2 nd 5 EX1 –IRS+IRS 10.6 1 <0.0011 YES

11 Result TABLE 2—McNemar’s tests results Test No. Test McNemar’s Statistic Freedom Pr > S Significance 6 EX2-IRS+IRS 1.2 1 0.27 NO 7 Total-IRS+IRS 9.0 1 <0.0027 YES 8 -IRS EX1 VS EX2 36.25 1 <0.0001 YES 9 +IRS EX1 VS EX2 58.7 1 <0.0001 YES 10 Total EX1 VS EX2 92.9 1 <0.0001 YES

12 DISCUSSION The sample of 200 implant images by Dentists and odontologists from 12 countries 22 manufacturers The most manufacturers Nobel- Biocare,Straumann,Branemark

13 DISCUSSION Differentiation intraoral and extraoral radiographs assessed in a single day Intra-Examiner = no significant Inter-Examiner = significant Implant Recognition System ( IRS )

14 conciusio n - Nonstandardized radiographs - Prior knowledge of each examiner - Modifications to the IRS