Presentation is loading. Please wait.

Presentation is loading. Please wait.

Open DWDM systems deployment Lada Altmannová CESNET www.ces.net Praha, May 14th, 2009.

Similar presentations


Presentation on theme: "Open DWDM systems deployment Lada Altmannová CESNET www.ces.net Praha, May 14th, 2009."— Presentation transcript:

1 Open DWDM systems deployment Lada Altmannová CESNET www.ces.net Praha, May 14th, 2009

2 2 CEF Networks Workshop 2009 Author participates on Optical networks activity of CESNET research program, GN3 and Phosphorus project Presented ideas do not necessarily reflect an official opinion of the GN3, CESNET or any other institution or project.

3 3 CEF Networks Workshop 2009 CESNET l CESNET2 network l Dark fibre experimental facility (EF) l 5 112 km leased fibres (high coverage on 78 864 km2 ) –Including 995 km of single fibre lines –Including Experimental facility 535 km of dark fibre

4 4 CEF Networks Workshop 2009 Motivation for lit fibre service l Full fibre capacity can be dedicated for NREN! (no return to traditional telco services) l NREN can share leased dark fibre with other organizations (legal bodies) l Lighting is outsourced (Some NRENs has no staff experienced in optics and electronics) l Buying of service instead of investment into equipment (OPEX instead of CAPEX) l Costs of adding lambdas (or other extensions) should be part of contract l Provider will obtain experience with new type of service and can offer this new type of service to other customers l Deployment of new photonics devices – technology transfer to telco providers

5 5 CEF Networks Workshop 2009 Used procedure – what we learned l Detailed description of procuring of lit fibres is on http://www.ces.net/events/cef2007/p/altmannova.ppt http://www.ces.net/events/cef2007/p/altmannova.ppt l Project of lighting can be prepared by NREN staff or by independent company l Contract with one provider per whole line l Detailed description of acceptance agreement (part of handover report) -Description of the line (address, contact persons, length, attenuation…) -Channel plan -Block diagram of the line (equipment, points of power measurement) -Tables and charts of measurement -Setting of equipment -Result and conclusion

6 6 CEF Networks Workshop 2009 Ways of lit fibres service acquiring l Upgrade of leased dark fibre lines (the most applied solution) – extensive experience l Tender for lit fibre l HW order and deployment by own staff (verification of new methods)

7 7 CEF Networks Workshop 2009 Previous situation in 2007

8 8 CEF Networks Workshop 2009 Steps of history l First CL (CzechLight) deployment in the year 2004, specifically CLA PB01 (CzechLight Amplifier 2in1, Booster and Preamplifier) was on Praha – Plzeň line with length of 159km in CzechLight EF and on Praha – Hradec Králové, length of 150km in CESNET2 network. l Since March 2005 CLA DI01 (CzechLight Amplifier DualInline)has been successfully working on CzechLight EF line Praha-Brno, 284km, as one and only inline amplifier. l At the beginning of 2006 CLA PB01 was equipped on the first Cross Border Fibre (CBF) line Brno – Bratislava, 182km. In the middle of 2006 CBF Brno – Vienna, 224km was deployed by a new prototype CLA PB02.

9 9 CEF Networks Workshop 2009 New optical transmission DWDM systems, based on own open photonic devices called the CzechLight (CL) family Main types without gain flattening for up to 8 channels: l CLA PB01 Low noise preamplifier and booster amplifier with output power up to 20dBm and optional ALS (Automatic Laser Shutdown) l CLA PB02 Low noise preamplifier and high-power booster amplifier with output power up to 27dBm and built-in ALS l CLA DI01 Dual in-line amplifier with output powers up to 15dBm Main types with gain flattening for up to 32 channels: l CLA PB01F Gain flattened low noise preamplifier and booster amplifier with output power up to 20dBm and optional ALS l CLA PB02F Gain flattened low noise preamplifier and high-power booster amplifier with output power up to 27dBm and built-in ALS l CLA DI01F Gain flattened dual in-line amplifier with output powers up to 15 dBm

10 10 CEF Networks Workshop 2009 CLA deployment up to 2007 CESNET2Type of CLANumber of CLALength (km)Since year Brno - BratislavaPB0121822006 Brno - VídeňPB0222242006 Praha - Ústí n. L.PB0121312007 Ústí n. L. - LiberecPB0121232007 CzechLight EF Type of CLANumber of CLALength (km)Since year Praha - Potěhy - BrnoDI01F, 2x PB02Fx32842005 Brno - Štetovice - CieszynDI01F, 2x PB02Fx32632007 Total deployed (December 2007) 14 1 207 CLA DI01 (originally CzechLight Amplifier DualInline) CLA PB01 (originally CzechLight Amplifier 2in1, Booster and Preamplifier)

11 11 CEF Networks Workshop 2009 CLA deployment 2008 - 2009 CESNET2Type of CLANumber of CLALength (km)Since year Brno - OstravaPB02F22352008 ČB - JihlavaPB01F21642008 Jihlava - BrnoPB01F21562008 Cheb - MostPB01F21712008 Letohrad - OpavaPB01F21862008 Most - Děčín - Ústí n.L.PB01F21352008 Most - Ústí n.LPB01F3682008 Plzeň - ChebPB01F21372008 Praha - PardubicePB02F21892008 Brno - ZlínPB02F21292009 Hradec Králové - PardubiceDI02F1302009 CzechLight EF Type of CLANumber of CLALength (km)Since year Praha - Jihlava PB02F21912009 Total deployed (January 2008 - May 2009) 24241 790

12 12 CEF Networks Workshop 2009 CLA deployment up to May 2009 CESNET2Number of CLALength (km)Since year 44062006 42542007 1914402008 31592009 CzechLight EFNumber of CLALength (km)Since year 32842005 32632007 2 1912009 Total deployment up to May 200938382 997

13 13 CEF Networks Workshop 2009 DWDM operational in 2009 and plans

14 14 CEF Networks Workshop 2009 Open DWDM system 10G with using of CzechLight Amplifiers on CBF CESNET2 Type of CLA Number of CLA Length (km) Brno - BratislavaPB012182 Ostrava – B. Biala (prepared change) PB01F2105 Brno - ViennaPB022224

15 15 CEF Networks Workshop 2009 CBF triangle for reliability

16 16 CEF Networks Workshop 2009 CBF one year statistics Bit rates [bps] Input bitrate min=0.000 max=2.552G avr=792.124M Output bitrate min=0.000 max=3.456G avr=1.281G One year load of Brno - Vienna author: Tom Kosnar, copyright: © 2004-2009, CESNET a.l.e Bit rates [bps] Input bitrate min=12.421M max=1.663G avr=274.505M Output bitrate min=7.633M max=3.656G avr=309.706M One year load of Brno - Bratislava author: Tom Kosnar, copyright: © 2004-2009, CESNET a.l.e

17 17 CEF Networks Workshop 2009 Pilot deployment l Project FTTH in Slovak Republic (Bánovce nad Bebravou) Link: http://internetprovsechny.cz/download/OptoNet- FTTx.ppthttp://internetprovsechny.cz/download/OptoNet- FTTx.ppt

18 18 CEF Networks Workshop 2009 Open DWDM deployment plans 2009 CESNET2Type of CLANumber of CLALength (km) Olomouc - ZlínPB01F272 Ostrava - OpavaDI02F144 Ostrava - KarvináPB01F269 Brno - KyjovPB01F292 Total7277 Total deployment up to December 2009453 274 Note : Blue - single fibre lines

19 19 CEF Networks Workshop 2009 Links l Detailed information about open photonics DWDM systems are availabe in CESNET Technical report on http://www.cesnet.cz/doc/techzpravyhttp://www.cesnet.cz/doc/techzpravy l Josef Vojtěch, Václav Novák, Miloslav Hůla :Open photonics DWDM systems deployment within the CESNET2 network, with emphasis to single fibre bidirectional operation l Current traffic statistics of above mentioned lines with CL equipment: http://www.cesnet.cz/provoz/zatizeni http://www.cesnet.cz/provoz/zatizeni

20 20 CEF Networks Workshop 2009 RESULTS l Enough time for project preparing and negotiation is necessary l After implementation and testing, 15 upgraded lines of CESNET2 are running with very high reliability l Projects are successful and can be repeated

21 21 CEF Networks Workshop 2009 Acknowledgement l CESNET colleagues, especially Jan Gruntorád, Miloslav Hůla, Tomáš Košňar, Václav Novák, Jan Radil, Stanislav Šíma, Josef Vojtěch l Neighbour colleagues Marian Ďurkovič, Marcin Garstka, Christian Panigl,

22 Thank you for your attention


Download ppt "Open DWDM systems deployment Lada Altmannová CESNET www.ces.net Praha, May 14th, 2009."