1 Controlli per terminali apr 07 FANCOILS CONTROLS ELECTRONIC BOARD - KCMS CMS - KCMS/PCM CMSPCM NEW WIRED CONTROL PANEL - KPCM

2 Controlli per terminali apr 07 n.2 FUNCTIONS

3 Controlli per terminali apr 07 n.3 IDROWALLIDROWALL FRENDFREND UTNBUTNB CONTROLLI UTNAUTNA YARDYEVYARDYEV BRIOEVBRIOEV UTNC-EVUTNC-EV IDROWALL FREND BRIOEV UTNC-EV CONTROLLI KPCMKTCMKICM

4 Controlli per terminali apr 07 n.4 CMS KCMS CMSPCM KCMS/PCM STI KSTIMVR KMVR RI-KRI CONTROLS KPCM KTCM KICM

5 Controlli per terminali apr 07 n.5 CMSPCM KCMS/PCM KPCM CMS KCMS New codes for electrical board and panel CONTROLS

6 Controlli per terminali apr 07 n.6 New electronic board KCMS CMS SCR ECO digital input dont change, SIC EIR change their position New digital input DI5 (not available for Frend and Idrowall) for new function: OCCUPANCY function (NC) only for KICM panel, (by modifying board parameters ( P45=8;P93=3) trough installer password on the KPCM control panel)

7 Controlli per terminali apr 07 n.7 New electronic board KCMS CMS New digital output CCH CCA

8 Controlli per terminali apr 07 n.8 FUNCTIONS SETTING FUNCTIONS COMFORT FUNCTIONS

9 Controlli per terminali apr 07 n.9 FUNCTIONS NOVELTY Full AUTO: the desired temperature is showed on the display. The unit, according to the room temperature and the setting temperature, sets the working mode (cool/heat). SETTING FUNCTIONS 1.Full auto 2.Cool 3.Dry 4.Fan 5.Heat 6.Heat + heater 7.Full Auto + heater KPCM KTCM KICM User set temperature P02=2°C P03=2°C P04=0,5°C mode room temperature HEAT OFF COOL Legend

10 Controlli per terminali apr 07 n.10 FUNCTIONS ATTENTION The following functions arent available with KICM control panel: Orienting/swing - Clock - Timer - Continuous ventilation (by key) – Keybord stop Probe IN/OUT function is available for: KICM trough DIP SWITCH (DIP6) setting KPCM trough key on the panel Not used with the remote control KTCM (the probe is always set in the unit) The periodic ventilation is always disabled with KPCM and KICM with Probe In function activated (probe into the unit) Confort control (by modifying board parameters P36=1 trough installer password on the KPCM control panel). COMFORT FUNCTIONS 1.Orienting/swing (on Idrowall) 2.Clock 3.Timer 4.Sleep 5.Hot start 6.Too cool 7.Memory 11.Economy (ECO) 12.Lock function / Blocco remoto (KICM) 13.ON/OFF remote control (SCR) 14.Summer/Winter remote control (EIR) 15.Security control (SIC) 16.Occupancy (only KICM) new 17.Probe IN/OUT 18.Continuous ventilation 19.Alarm 20.MASTER/SLAVE 21.Periodic ventilation 22.Confort control new 23.Blocco tastiera (solo KTCM) KPCM KTCM KICM

11 Controlli per terminali apr 07 n.11 User set temperature P02=2°C P03=2°C P04=0,5°C mode room temperature HEAT OFF COOL Legend COMFORT CONTROL FUNCTION Comfort control (by parameters) When the set-point is decided by a system manager (supervision), the Comfort Control function gives the possibility to increase or reduce the Set-point (+-3°C) in the room with the UP-DOWN bottoms. (The function have to be enable modifying board parameters P36=1 trough installer password on the KPCM control panel.) The set value is 22 °C 22°C

12 Controlli per terminali apr 07 n.12 LOCK FUNCTION FUNCTION Attention: to obtain the changing set- point ±3°C must be set the Confort Control Function

13 Controlli per terminali apr 07 n.13 Changes to the DIP-Switches must be made with the board disconnected from the power supply. The DIP-Switches on the electronic board (see right figure) can be changed using a sharp tool. The DIP- Switches can be changed correctly by following the instructions present on the component and in the following table. DIP-SWITCHES

14 Controlli per terminali apr 07 n.14 In case of supervising system (BMS) with OCCUPANCY function it is possible to activate 3 different working modes ( by modifying board parameters P45=8; P93=3 trough installer password (60) on the panel) : Not booked room = OFF Occupied room = Comfort mode Booked and not occupied room = Stand-by/Economy mode Not occupied Not occupied OFF Occupied Occupied Comfort mode There is a person in the room. The fancoil works with desired temperature value for fixed time (15 min). Set-point = desired temperature value The occupancy status can be activated: By one of the keys in the panel (not ON/OFF) for a set period of time (parameter P94=15 min). At the end of the time periods (15 min) the occupancy status can be enabled again With movement sensor on DI5 digital input Pressing Sleep key for 5 sec the Occupancy function continues up to unit switch-off Booked and not occupied Booked and not occupied Stand-by/Economy mode There is no person in the room. The fancoil works with economy set-point for energy savings Set-point = economy * Only with ECO (DI4, parameter P44=8) ONLY x KICM DIGITAL INPUT/FUNCTION: OCCUPANCY (NOT FOR IDROWALL FREND* ) NOTA BENE Con funzione Occupancy abilitata non utilizzare lingresso igitale ECONOMY

15 Controlli per terminali apr 07 n.15 CCH Chiller input, chilled water required from the thermostat (NO) DIGITAL OUTPUT: FUNCTION CCH –Chiller input

16 Controlli per terminali apr 07 n.16 CCA Boiler input, hot water required from the thermostat (NO) DIGITAL OUTPUT: FUNCTION CCA – Boiler input