1 Office Post-Processing

2 Download Note: Static observation data are only stored in the receiver and hence receiver is required to be connected to the PC for downloading.

3 Topcon Tools If you are running on demo mode the following will popup If you are not running on demo mode the following will popup Note: If you receive Sentinel protection driver not installed it means the driver for the USB needs to be installed first.

4 Topcon Tools – New Job Click here Enter name Enter here Click here

5 Topcon Tools – Configuring Click here Enter the observation precision for you project

6 Topcon Tools – New Datum Click here

7 Topcon Tools – New Datum Click here Check with your local authority for the value

8 Topcon Tools – New Projection Click here Select your custom datum Click here

9 Topcon Tools – New Projection Click Here Check with your local authority for the value

10 Topcon Tools – New Projection Scroll this Select your custom projection

11 Topcon Tools – New Projection Click Here

12 Topcon Tools - Configuring Click Here

13 Topcon Tools - Configuring Click Here

14 Topcon Tools – Import Data Click here

15 Topcon Tools – Import Data Select this Automatic search for GPS+ receivers Note: For GRS-1 it will be Mobile device

16 Topcon Tools – Import Data Select your receiver Click HereClick here

17 Topcon Tools – Control point Click here and select what type of control point you want it to be If you are using an auto pos for coordinate you require to key in the actual coordinate The icon will change to triangle to show that it is a control point

18 Topcon Tools – Antenna Info Select this

19 Topcon Tools – Antenna Info Click here Enter all antenna type and height

20 Topcon Tools – PostProcessing Click here

21 Topcon Tools - Adjustment Green = Post-Processing Passed!!! Click here Red = Post-Processing Failed!!! Baseline: Tips: Make sure all baselines have passed post-processing before adjustment!!!

22 Topcon Tools - Adjustment Click here

23 Topcon Tools - Adjustment PASSED!!!

24 Topcon Tools - Options Right - Click Click here

25 Topcon Tools - Options Click here

26 Topcon Tools - Adjustment

27 Topcon Tools – Report Click Here

28 Topcon Tools – Report Click Here