Presentation is loading. Please wait.

Presentation is loading. Please wait.

32003200 Simplicity Easy configuration with Quick Start codes Parameter help scrolling text messages Custom text messages Customisable operator scroll.

Similar presentations


Presentation on theme: "32003200 Simplicity Easy configuration with Quick Start codes Parameter help scrolling text messages Custom text messages Customisable operator scroll."— Presentation transcript:

1 32003200 Simplicity Easy configuration with Quick Start codes Parameter help scrolling text messages Custom text messages Customisable operator scroll list Wizard for configuring advanced features Features In built timer. Programmer option Master comms for multi-zone programming CT input with load diagnostics Recipe function: 5 x 38 parameters

2 32003200 Features Relay, logic or dc outputs Heat, cool, alarm outputs Dc control or retransmission 8 segment programmer Ammeter display RS232/RS485 3-wire Modbus Green or Silver coloured facia 3216 Size 48 x 48 3208 Size 48 x 96 3204 Size 96 x 96 AVAIL Oct 04

3 32003200 Programmer RUN Servo to SP or PV RESET Temp Time Programming = Rate, target, time X 4 End Type = Dwell End Type = OFF Holdback at start of dwell END Tip: Use Recipe function to store 5 programs with user defined names

4 32003200 3216 Master programmer Broadcast address 0 is used Master digital comms Applications Multizone stress relieving - EHS, 1200 units pa Multizone ovens and furnaces MODBUS Slave controllers Use Remote SP address 1A

5 32003200 Hot runner Controller What are hot runner controllers? They are used on injection moulding machines to stop the plastic freezing as it runs into long narrow channels in the mould. These channels are kept warm by embedding cartridge heaters into the mould. The cartridges are hydroscopic (absorb water) and need to be slowly dried out to overcome earth leakage, shorted turns and overheating. The hot runner (soft start) controller delivers a reduced power output until a set temperature or time is reached. The controller then reverts to normal PID control. Phase angle thyristors are often used to control the heaters. The 3216 DC provides a very economical solution. Soft start setpoint) Soft start time

6 5 Quick Start Set 1 32003200

7 6 Quick Start Set 2 32003200 10 Amps 25 Amps 50 Amps 100 Amps Not Fitted x 6 CT input 1 2 5 Acknowledge AlarmW ManualM Run/HoldR Key LockL Setpoint 2P ResetT Remote Setpoint CommsU Recipe 2 / 1 selectV Not Fittedx Dig in 1

8 7 ApplicationsApplications ChillersChillers Calibration baths and blocksCalibration baths and blocks SterilizersSterilizers Vacuum formingVacuum forming Packaging (O Series)Packaging (O Series) ExtrusionExtrusion Injection moulding - hot runnersInjection moulding - hot runners Baking ovensBaking ovens Small Kilns and furnacesSmall Kilns and furnaces Cold storesCold stores

9 8 Success Stories Cincinatti - AustriaCincinatti - Austria Application: Extrusion. Quantity:2,000 units pa Selling points: - One item stocked. Recipes used to select Heat only, heat/cool or indicator. - Custom alarm messages EHS - UKEHS - UK Application: Stress relieving Quantity:1,200 units pa Selling points: - User specific interface - Master comms programmer

10 9 Success Stories Sterling - USASterling - USA Application: Chillers (extrusion). Quantity:2,500 units pa Selling points: - Timer for flushing the cooling system - Timer for flushing the cooling system Tulis Hot Press -UKTulis Hot Press -UK Application: Vacuum sealing Quantity:300 units pa Selling points: - Timer for vacuum pump - DC for power limit for phase angle thyristor

11 10 Success Stories SwitzerlandSwitzerland Application: Ovens (for keeping Aluminium molten) Quantity:200 units pa Selling points: - DC output - 24Vdc supply ItalyItaly Application: Dental furnace Quantity:400 units pa Selling points: - Dc output

12 11 3208/043208/0432083208 3208: Available Aug 2004 3204: Available Sept 2004

13 12 The future 32003200 3200 Low voltage - Q4 VP - Q3 Membrane front - Q3 Dual AA relay in 3216 - Q3 FM and DIN3440 Indicator and alarm unit - Q3 3208i Indicator and controller - Q4