1 Balboa Pacific Corporation Waste Management & Power Generation Technology Waste Management & Power Generation Technology

2 Balboa Pacific Corporation. Solutions to Waste Management must be addressed technologically. Using Mother Earth as a waste depository – land or sea, is unacceptable. And incineration pollutes the air we breathe. It is incumbent upon mankind to serve as stewards of the planet we inhabit.

3 Balboa Pacific Corporation Bal-Pac Thermal Converter Bal-Pac Thermal Converter OUR TECHNOLOGY Pyrolytic Gasification Pyrolytic Gasification

4 Balboa Pacific Corporation Environmentally clean process. Controlled environment inside pyrolytic units. Energy efficient process. Controlled temperature in every stage of the process. Portability - can be moved easily. Can generate up to 3 Megawatt hours of power per 50 ton system per day. Advantages of Bal-Pac Pyrolytic Gasification for processing waste streams Advantages of Bal-Pac Pyrolytic Gasification for processing waste streams

5 Balboa Pacific Corporation Advantages of Bal-Pac Pyrolytic Gasification for processing waste streams Advantages of Bal-Pac Pyrolytic Gasification for processing waste streams It is a continuous-feed process Volume reduction of the material, up to 95% depending on waste composition No toxic residue, non-leachable (ash) No toxic emissions into the air Creates heat energy as a by-product Temperature range of Thermal Oxidizer as high 2600°F

6 Balboa Pacific Corporation System stack Thermal Oxidizer Thermal Converter Waste Conveyor Waste Material Shredder/ Pelletizer Char Waste Heat Boiler Steam Turbine Generator Thermal Converter operates between 1200 & 1800°F Thermal Converter operates between 1200 & 1800°F Thermal Oxidizer operates between 1600 & 2600°F Thermal Oxidizer operates between 1600 & 2600°F Waste-heat Boiler pressure = 250 psi Waste-heat Boiler pressure = 250 psi Multi-stage steam turbine generator Multi-stage steam turbine generator Typical System

7 Balboa Pacific Corporation Indirect heat Indirect heat Oxygen free Oxygen free Indirect heat Indirect heat Oxygen free Oxygen free Temperatures between Temperatures between 1200 & 1800°F. Continuous process Continuous process Temperatures between Temperatures between 1200 & 1800°F. Continuous process Continuous process How It Works

8 Balboa Pacific Corporation. Different Waste Streams Processed By Bal-Pac Pyrolytic Gasification Municipal Solid Wastes Household, Commercial Centers, Buildings, Markets, Restaurants and Fast Food Eateries, Schools, Yard Waste, etc. Industrial Wastes Oil Refineries Chemical Plants Metallurgical / Mining Industries Hospital Waste (Red Bag Waste) Electronic Industries (Chips, ICs, MPs) Steel Mills Plastic, Paper, Paints Rubber goods including tires Drum Waste Electrical Products (PVC, PE Insulation) Etc Contaminants successfully destroyed

9 Balboa Pacific Corporation Ash Residue California Thermal Converter EPA Limits Test Results Barium100 mg/1 0.37 mg/1 Cadmium1 mg/1 0.1 mg/1 Lead5 mg/1 0.58 mg/1 Arsenic5 mg/1 0.050 mg/1 Selenium1 mg/1 0.05 mg/1 Chromium5 mg/1 0.01 mg/1 4-Methalene Pentanone7 mg/1 2 mg/1 Benzene0.5 mg/1 0.1 mg/1 Benzoic AcidN/A 170 mg/1 Di-N-Octyl PhythalateN/A 4 mg/1 Emission Levels

10 Balboa Pacific Corporation StackCalifornia Thermal Converter EmissionsEPA Limits Test Results Particulate 0.080g 0.051g CO (carbon monoxide) 50 ppm 1 ppm SO 2 (sulfur dioxide)150 ppm 24 ppm HCI (hydrogen chloride) 50 ppm 6 ppm NO X (nitrogen oxides)200 ppm 68 ppm Emission Levels

11 Balboa Pacific Corporation A Comparative Analysis Bal-Pac Pyrolytic Gasification versus Incineration Decomposes oxygen free, converts to gas and carbon char Decomposes oxygen free, converts to gas and carbon char Thermal destruction with direct flame and high oxygen Low air flow (low Nox) High air flow (high Nox) No toxic emissions (no Furans or Dioxins) No toxic emissions (no Furans or Dioxins) Generates Furans and Dioxins 90-95% reduction in volume and weight 90-95% reduction in volume and weight Maximum 80% reduction Creates energy up to 10BTU Uses energy Secondary control device rarely required (Scrubber or Dust Collector) Secondary control device rarely required (Scrubber or Dust Collector) Secondary control device always required

12 Balboa Pacific Corporation the process Energy rich - for every BTU* input, expect as much as 10 BTU output. Superb waste-to-energy potential. Bal-Pac Systems meet all environmental regulations and guidelines. * BTU - British Thermal Unit

13 Balboa Pacific Corporation the process the process Destructive distillation of ALL organic materials through a process that involves the application of intense indirect thermal energy in the absence of oxygen which reduces the material to combustible gases and non-hazardous char. Able to achieve up to 95% reduction in volume of many materials.

14 Balboa Pacific Corporation For Mixed-Use Application Bal-Pac Thermal Converters can process: 1.Municipal waste 2.Industrial waste 3.Hospital waste 4.Household waste Bal-Pac Thermal Converters can: Generate / Create power for re-distribution within the same work area or re-sold to a local electric company

15 Balboa Pacific Corporation For Industrial Application Waste Management facility ideal for the final destruction of Toxic and Hazardous Waste (THW). Ideal for use as Waste Management facilities and power generating plants unit within industrial parks.

16 Balboa Pacific Corporation. For Industrial Application An income generator because it processes not only internally generated waste, Bal-Pac offers one the option of treating waste from nearby industrial parks for a fee. A cost-cutting measure because it can generate up to 3 Megawatt hours of electricity per 50 ton system per day for use within the same industrial estate.

17 Balboa Pacific Corporation RRT Designs & Construction Melville, New York. Alstom Power Air Preheater Divison Wellsville, New York RRT Designs & Construction Melville, New York. Alstom Power Air Preheater Divison Wellsville, New York Materials recovery facility EPC, O&M MSW processing & recycling, transfer & collection systems T&O MSW feedstock for RDF and COMPOST Recyclable marketing services for paper, plastics, glass, metals, textiles, wood, aggregate, etc. Waste-to-energy ash metals recovery Materials recovery facility EPC, O&M MSW processing & recycling, transfer & collection systems T&O MSW feedstock for RDF and COMPOST Recyclable marketing services for paper, plastics, glass, metals, textiles, wood, aggregate, etc. Waste-to-energy ash metals recovery Leading supplier of engineered products, services and technologies for heat recovery systems, size reduction and classification equipment thermal processing and destruction equipment including custom manufacturing Maintains a fully-equipped application laboratory and test center in Naperville Illinois, that offers pilot plant capabilities to simulate actual plant operations their products APC manufacturing facilities in Concordia, Kansas and Wellsville, New York are both certified to AWS.D1.1 and ASME Section 1 and Section VIII certifications. The Concordia shop is also certified to ASME Section IV – Heating Boilers (H Stamp). Leading supplier of engineered products, services and technologies for heat recovery systems, size reduction and classification equipment thermal processing and destruction equipment including custom manufacturing Maintains a fully-equipped application laboratory and test center in Naperville Illinois, that offers pilot plant capabilities to simulate actual plant operations their products APC manufacturing facilities in Concordia, Kansas and Wellsville, New York are both certified to AWS.D1.1 and ASME Section 1 and Section VIII certifications. The Concordia shop is also certified to ASME Section IV – Heating Boilers (H Stamp). Strategic Alliances in Technology

18 Balboa Pacific Corporation For Further Information Contact Douglas F. Golding Chief Operating Officer P.O. Box 10454 Costa Mesa, CA 92627 (949) 722-6563 Doug@Balboa-Pacific.com www.Balboa-Pacific.com


Download ppt "Balboa Pacific Corporation Waste Management & Power Generation Technology Waste Management & Power Generation Technology."

Similar presentations


Ads by Google