Presentation is loading. Please wait.

Presentation is loading. Please wait.

Device Server Sales-Kit IAG ICOM PM Robin Lin 2013, Q4.

Similar presentations


Presentation on theme: "Device Server Sales-Kit IAG ICOM PM Robin Lin 2013, Q4."— Presentation transcript:

1 Device Server Sales-Kit IAG ICOM PM Robin Lin 2013, Q4

2 Intelligent Automation, Seamless Integration

3 Application Layer Service Layer Network Layer Sensor Layer Advantech IoT Product Development Framework Management Environment Monitoring Industry Monitoring Building Automation Intelligent Transport Public Security Smart HomeSmart Grid Scheduling SuiteData AnalysisSCADAGeo. Infor Data Concentrator NGN Multi- Network Integration Connection Device

4 Simplify The Way You Connect Communication Technologies GPRS 3G Wi-Fi Ethernet Fiber Optic Smart Connection Penetrate Vertical Markets Connect Technologies Transportation, coal mining, smart grid, and IT market From serial to mobile connectivity, transparent information Develop ICOM FCP Serial

5 DEVICE CONNECTIVITY -Device Server -iGateway

6 iGateway : Device Connection Solution for IoT World Application Layer Service Layer Network Layer Sensor Layer Management Environment Monitoring Industry Monitoring Building Automation Intelligent Transport Public Security Smart HomeSmart Grid Scheduling SuiteData AnalysisSCADAGeo. Infor Data Concentrator NGN Multi- Network Integration Connection Device GPRS IP Gateway 3G IP Gateway Ethernet Device Server WLAN Device Server

7 iGateway Product Portfolio Serial to Cellular IP Gateway -4-band GPRS support -Accurate & Reliable backup solution(dual-SIM & SD card) -Advanced function (VPN & SMS tunneling) Serial to Wi-Fi Device Server b/g/n standard support -Infrastructure, Ad-Hoc and peer-to-peer mode support Serial to Ethernet Device Server -Redundant Ethernet/Power input -Flexible and easy to use design -ESD/EFT/isolation protection Modbus Data Gateway -Modbus RTU/ASCII to Modbus/TCP -Reduntant Ethernet/Power input

8 Serial to Ethernet Device Server

9 Serial Device Server Ethernet Simplify the Complexity

10 What if You Could… Quickly and easily replace limited distance serial connection with an anywhere/anytime access – Leverage existing Ethernet and IP networking infrastructure – Access anywhere if theres network connection – No distance limitations! RS-232 Device Server LAN / WAN

11 Weakness and Challenges Only one Ethernet connection impacts stability Data Loss according to Ethernet disconnection Typically serial port will be occupied by dedicated PC/Host Other PC/Hosts can not share the serial data PLC RTU Device Server Temp:???? Pressure:???? Marquee Display RS-422/485 RS-232 RS-422/485 Barcode Scanner

12 It all Starts with Our Device Server Device Server is a gateway between serial devices and Ethernet (TCP/IP) Serial data is encapsulated in IP packets and transported over the network - like a letter in an envelope via the postal service Dual Ethernet connection for full redundancy solution Ethernet RS-232/422/485 Serial Device Server RS-232/422/485 Serial Network Ethernet Panel / Label Printer ADAM-5000 Primary Secondary

13 EKI-152/1522/1524 Hardware Overview Dual 12 ~ 48 Vdc inputs Reverse power polarity protection Fault relay for external PLC/controller IP30 metal chassis Din-rail or wall mount Wide operating temperature -10 ~ 60C Dual/Redundant 10/100Base-Tx Ethernet ports Built-in 1.5KV magnetic isolation protection 1/2/4-port RS- 232/422/485 software selectable serial ports D-Sub9 convert to terminal connector accessory is available : OPT1-DB9-AE Serial ESD protection: 15KV for all signals 1KV burst (EFT), 0.5KV surge protection for power inputs

14 EKI-1528/1526 Hardware Overview IP30 metal chassis Front-end LED display Wide operating temp. (-10 ~ 60C) Hardware reset button Restore to default Serial console port Supports 110 ~ 240 VAC/VDC power input Dual 10/100Base-Tx Ethernet ports for LAN redundancy 8/16-port RS-232/422/485 software selectable serial ports 15KV ESD protection for all signals RJ45 connectors

15 Advantech Serial Device Server Utility Network enable existing COM-port based software For Windows 2000/XP/Vista/7 (both 32/64-bit) Supports up to 4096 virtual COM ports Auto configuring all serial ports by simple clicking Easy setting thru. 3 Steps setup wizard to create Virtual COM port

16 Serial Device Server Operating Modes There are several modes of operation, depending on application requirements Typical modes are: – TCP server w/ COM redirector (VCOM) – TCP Server (devices polled by host PC) – TCP Client (event driven devices – barcode scanner) – Pair Configuration (Peer-to-Peer: serial extension cord)

17 Mode: TCP Server w/Redirector (VCOM) COM port redirection software (included in the utility) is installed on computer Remote devices are addressed as virtual COM ports Application: – Legacy PC-based software application Windows Native COM Port Driver Legacy Application Software Virtual COM Port Ethernet Host Computer Ethernet RS-232 Device Server Serial

18 Mode: TCP Server (Polled) Connection is initiated by the host computer Applications: some OPC servers & IP-aware software Serial Devices Ethernet Panel / Label Printer PAC/PLC TCP Frame Marquee Display

19 Mode: TCP Client (Event Handling) Connection is initiated by the Device Server Data destination is specified at Device Server setup Applications: barcode/RFID scanner, GPS receiver, etc. Serial Devices Ethernet RFID Scanner Barcode Scanner

20 Mode: Pair Connection (Peer to Peer) Connection is initiated by either Serial Device Server Application: an RS-232 extension cord, interconnecting devices over LAN/WAN Ethernet RS-232 Device Server Device Server RS-232

21 Application: Manufacturing Remote PCL programming/diagnostics Benefits Time Savings – remote access from your desktop or laptop (via VPN) Increased Flexibility – access any device from any desktop/laptop Reduced Cost – leverage existing IP LAN/WAN infrastructure instead of installing dedicated cabling Ethernet RS-232 EKI-1521 Device Server Host Computer with COM Port Redirection

22 Application: Network enabled barcode scanners Benefits Rapid Integration – Quickly and easily connect disparate devices Increased Flexibility – overcome distance limitations of serial devices Ethernet EKI-1521 Device Server Host Computer with COM Port Redirection Supports up to 4096 ports RS-232 EKI-1521 Device Server RS-232

23 Application: Taipei MRT PIDS Benefits Quick response time (Below 10ms) – Update information in time and without data lost Independent operation mode for each port – Supports to connect various serial devices on site Control Center EKI-2741F Fiber Fiber (to next station) RS-422 RS-485 Plasma TV LED Display EKI-2528

24 Application solution: Power substation Robustness by IEC conformity. milliseconds accurate clock synchronization (DCF77, GPS, IEC /104, NTP) IEC to -104, IEC61850 and DNP3 communication standards. Power 1mS SOE (Sequence Of Event )

25 Key Selling Features High baud rate and extreme data throughput – Ensure the high volume transmission needs – Ex. Batch transfer…etc Quick response time (below 10ms) for each port – Specially suitable for manufacturing automation and critical communication – Ex. Gaming machine SNMP and alert to report status instantly – SNMP MIB-II for network management – SNMP trap and mail alert for warning status be changed

26 Key Selling Features (cont) Dual Ethernet connection for LAN redundancy – It will switch to backup Ethernet connection automatically when the major LAN be disconnected Multi-Access and COM port sharing – Multi hosts can share the COM port data or access the COM port in sequence Rich configuration methods – Windows utility, WEB interface, telnet, and serial console

27 Serial to WiFi Device Server

28 EKI-135X Hardware Overview Dual 12 ~ 48 Vdc inputs Reverse power polarity protection Fault relay for external PLC/controller IP30 metal chassis Din-rail or wall mount Wide operating temperature -10 ~ 55C Wi-Fi b/g Serial ports RS- 232/422/485 software selectable D-Sub9 convert to terminal connector accessory is available : OPT1-DB9-AE Serial ESD protection: 15KV for all signals 1KV burst (EFT), 0.5KV surge protection for power inputs

29 EKI-135x Wireless Device Server w/COM port redirector COM port redirection software is installed on host Remote devices are addressed as a virtual COM port RS-232/422/485 Serial Network Ethernet ADAM-5000 Virtual COM port Temperature Controller EKI-6311GN Wireless AP

30 Application: Remote LED Display Benefits Transparency – No changes required to RS-232 based display or software Cost Savings – Rapid installation without the need to pull or bury communications cable Ethernet RS-232 EKI-1352 Device Server Host Computer with COM Port Redirection b/g Access Point

31 Device Server Apps: OEM Telematics Management via local b wireless Benefits Rapid Time to Market – Quickly add wireless access to any device with a serial port Time Savings – replace manual record keeping keeping (fares, mileage, etc.) with automatic download on returning to the depot Reduced Cost – optimize maintenance with better access to vehicle performance data Ethernet EKI-1351 Wireless Device Server Host Computer b/g Access Point

32 EKI-6311GN n Wireless AP EKI-6311GN n Wireless AP EKI-1352 Wireless Device Server EKI-1352 Wireless Device Server Application: AGV (Automated Guided Vehicle)

33 PLC P2P Wireless connection Wireless Device Servers b/g wireless connection Virtual Serial Tunnel – By simple configuration – Wireless connection – No program change Connect to each moving devices Wireless Network (Virtual Serial Tunnel) EKI-1351 PLC Country: Japan Customer: Diatrend Country: Japan Customer: Diatrend

34 Serial to Cellular IP Gateway

35 Serial to GPRS IP Gateway feature Compact Compact and Slim with solid mounting Advanced Supports versatile gateway features Efficient Supports various communication interfaces Simplicity Easy to use software features Accurate High redundancy with dual SIM and SD slots for data buffering Reliability Robust HW design

36 Dual Power Inputs (12 to 48 VDC) Reverse Power Polarity Protection Fault Relay for external PLC/Controller Dual SIM SD Slot 5 Band GPRS Serial Ports RS-232/422/485 Serial ESD Protection: 15KV 2KV EFT/Surge protection for Power 2KV isolation (EKI-1321) EKI-132x Hardware Overview 10/100/1000 Ethernet EKI-1321 : 1-port EKI-1322 : 2-port Operating Temp -30 to 65°C

37 Simplicity: Reduced Software Complexity Advantech Device Server Utility Easy Configuration thru Web 3~5 Steps to startup… INTERNET

38 Accurate, Highly backup solution INTERNET Remote Control Room Ethernet RS-232 ADAM-5510M UNO-2171 Traffic Information Display Board TC BOX Weather Sensor Fog Station, Wind Speed, Rainfall 75~921.6K any baud rate setting Dual SIM for communication Redundancy SD card for data buffering…

39 Modbus Device Server

40 Overview (Modbus Gateway) What is Modbus Gateway A gateway that converts Modbus/RTU or Modbus/ASCII to Modbus/TCP Why use Modbus Gateway In some situation that SCADA queries Modbus/TCP data while device only supports Modbus/RTU, we need a Modbus Gateway to do the conversion Modbus Gateway extends transmission distance of RTU devices via network connection

41 Modbus Overview Communications protocol introduced in the mid 1970s by Modicon Now an open standard with broad vendor support Most popular industrial protocol world-wide Implementation is master/slave (client/server) Modbus ASCII Asynchronous serial (RS-232/422/485) Oldest of implementations Modbus RTU Asynchronous serial (RS-232/422/485) Most efficient (binary), and most popular Modbus TCP Ethernet and TCP/IP networks only Modbus Master Modbus Slave Modbus RTU RS-485

42 How Do You Bridge the Modbus Gap? Most new equipment is Modbus/TCP Modbus serial and Ethernet versions not designed to work with each other Large installed bases of Modbus serial How do you preserve current investments? Is there a way to bridge the old and new? What about serial only Modbus devices?

43 You Need Modbus Gateways ! Converter of Modbus/TCP and Modbus/RTU, Modbus/ASCII Extends transmission distance of RTU devices via network connection

44 EKI-1221/1222/1224 Hardware Overview Dual 12 ~ 48 Vdc inputs Reverse power polarity protection Fault relay for external PLC/controller IP30 metal chassis Din-rail or wall mount Wide operating temperature -10 ~ 60C Dual/Redundant 10/100Base-Tx Ethernet ports Built-in 1.5KV magnetic isolation protection Serial ports RS- 232/422/485 software selectable D-Sub9 convert to terminal connector accessory is available : OPT1-DB9-AE Serial ESD protection: 15KV for all signals 1KV burst (EFT), 0.5KV surge protection for power inputs

45 EKI-1221D/1222D Hardware Overview Dual 12 ~ 48 Vdc inputs Reverse power polarity protection Fault relay for external PLC/controller IP30 metal chassis Din-rail or wall mount Wide operating temperature -10 ~ 60C Dual/Redundant 10/100Base-Tx Ethernet ports Built-in 1.5KV magnetic isolation protection Serial ports RS- 232/422/485 software selectable D-Sub9 convert to terminal connector accessory is available : OPT1-DB9-AE Serial ESD protection: 15KV for all signals 1KV burst (EFT), 0.5KV surge protection for power inputs Build-in Ethernet Switch function

46 Features Baud rate from 50 to 921.6K bps Dual Ethernet Port – Daisy Chain Feature – Auto By-Pass – Multiple TCP Master from different domain – Multiple TCP Slave to different domain Easy to use – Auto searching slave ID Dual Power Input

47 Dual Ethernet Redundancy Dual connection enables an alternative backup session RS-232 HMI Modbus RTU/ASCII Master devices Modbus/TCP Slave devices Ethernet #1 Ethernet #2

48 Dual Ethernet Connection Multiple TCP master from different domain Modbus/TCP master devices Ethernet #1 Ethernet #2 Modbus/RTU Slave device

49 Dual Ethernet Connection RTC master to TCP slaves on different domain Modbus/TCP slave devices Ethernet #1 Ethernet #2 Modbus/RTU Master device

50 Easy to Use Utility will search related slave ID automatically Host Computer RS-485 Modbus RTU/ASCII Slave Devices ID:1ID:3ID:4ID:27 Ethernet Modbus RTU/ASCII Master

51 EKI-1221/1222/1224 Modbus Gateways Integrated hardware/software solution to connect serial and Ethernet devices Modbus/TCP to Modbus ASCII or RTU Modbus ASCII or RTU to Modbus/TCP Transparent – no changes required to attached devices/equipment Preserve installed equipment investments Integrate devices without Ethernet EKI-1221: 1-port EKI-1222: 2-port EKI-1224: 4-port Modbus/TCP Ethernet Modbus RTU RS-485 Modbus Gateway

52 EKI-1221D/122D Modbus Gateways w/ Daisy Chain With the same function as EKI-122x Modbus Gateway Build-in ethernet switch to allow daisy chain connection EKI-1221D: 1-port EKI-1222D: 2-port Modbus/TCP Ethernet Modbus Gateway Modbus Gateway Modbus RTU RS-485 Modbus RTU RS-485

53 Key Feature - Daisy-chain Connection Built-in Ethernet switches to allow Daisy-chain connection Helping improve scalability Saving wiring cost legacy

54 Modbus Gateway Basic Application Scenario The Serial device acts as a slave device that will be polled by Ethernet Master device.

55 Daisy-Chain Application Scenario Benefit Daisy-chain for easy wiring Brain/coupler-less Flexible serial-port selection Multiple mounting methods

56 Selection Guide

57 Easy Selection How many serial devices to connect? If more than 1 device, how apart are they? Serial tunneling or Modbus Gateway? Wired or Wireless? Panel (Din-rail) or rack-mount configuration?

58


Download ppt "Device Server Sales-Kit IAG ICOM PM Robin Lin 2013, Q4."

Similar presentations


Ads by Google