Dry Air Systems, Inc WelcomeWelcome Dry Air Systems, Inc. Holds the key for clean, dry air systems.

Similar presentations


Presentation on theme: "Dry Air Systems, Inc WelcomeWelcome Dry Air Systems, Inc. Holds the key for clean, dry air systems."— Presentation transcript:

1

2 Dry Air Systems, Inc WelcomeWelcome

3 Dry Air Systems, Inc. Holds the key for clean, dry air systems

4 Compressed air contains: Water Contaminants Left unprotected –W–Water (temperature) –C–Contaminants (oil)

5 The problems: All air systems trap and contain water moistureAll air systems trap and contain water moisture Water and contaminants harm:Water and contaminants harm: –pneumatic controls performance –their life expectancy –reservoir capacities –affects air compressor duty cycles

6 Typical Offerings Include ChillersChillers –expensive to operate –labor intensive to install –limited efficiencies –space robbers

7 Smaller Offerings Water separatorsWater separators –ineffective –limited capabilities –no dew point

8 Today's Offerings Current desiccant dryersCurrent desiccant dryers –difficult to maintain –limited filtering capabilities –short service intervals –cannibalizes excessive air for regeneration

9 ImprovesImproves system reliability PneumaticPneumatic controls protection IncreasedIncreased life expectancy FullFull reservoir capacities ExpansionExpansion flexibility CompactCompact sizes QualityQuality of workmanship Dry Air Systems Offers:

10 Benefits To Air Quality Filters to 15 SCFM.2 of 1% Regen Clean Dry Continuous molecular sieve regeneration -40 Pressure dew point depression Continuous air flow Built-in moisture indicator (optional)

11 Identifying the Units Components Air dryers (2 min.) Mounting bracket Inlet, outlet, purge & control ports MLT valve or PLC Safety valves Mufflers Moisture indicator (opt.)

12 Now, the Dryer Stuff How and Why they do what they do

13 Air Dryer Components RegenerationRegeneration InletInlet PurgePurge SafetySafety Desiccant Adapter Plate Bottom Cap Mounting Bracket ValvesComponents

14 The Bottom Cap Inlet Check Valve BottomBottom Cap UnloaderUnloader Valve (purge)

15 Adapter Plate Regeneration Valve Adapter Plate

16 The Desiccant Cartridge

17 Spring Bag & Desiccant 3 Filters Outer Canister Inner Canister Desiccant Cartridge Guts

18 To Air System Compressor Sequencer

19 Compressor Governor.010 Orifice From air system

20 MLT valve Moisture Indicator To shop air system From air compressor Mufflers 200 PSI Safety Valve 200 PSI Safety Valve Air signal lines MLT to Unloader Air dryer Unit

21 The Dryers Work This Way Micro logic timer (MLT) controls unitsMicro logic timer (MLT) controls units One dryer receives contaminated airOne dryer receives contaminated air Second dryer self regeneratesSecond dryer self regenerates

22 Inlet check valve closed Purge Air Air signal from MLT to Unloader Valve Dryer A Charge B Regeneration From Air Compressor Dry filtered air to air system MLT valve Inlet check valve open

23 Purge Air Air signal from MLT to Unloader Valve Dryer B Charge A Regeneration From Air Compressor Dry filtered air to air system MLT valve Inlet check valve open Inlet check valve closed

24 Custom Designed Air Dryer Systems For... EaseEase of installation FlexibilityFlexibility for expansion SimplifiedSimplified dryer maintenance CostCost effectiveness CompleteComplete pneumatic air system protection

25 The Expandable System Designed for a variety of compressor sizes and duty cycles

26 Expandable

27 The Process From Compressor To Air System

28 Dry Air Systems offer Clean, dry air for air systems reliabilityClean, dry air for air systems reliability Elimination of waterElimination of water Reduced compressor duty cyclesReduced compressor duty cycles Operational costs comparable to 75-watt light bulb (Chillers)Operational costs comparable to 75-watt light bulb (Chillers) Competitive pricingCompetitive pricing Less than.2% of air required for regeneration flow 100SCFM 120PSI.Less than.2% of air required for regeneration flow 100SCFM 120PSI.

29 Benefits Review Reduced operating costsReduced operating costs –Electrical (chiller) –Reduced compressor duty cycles Dew Point DepressionDew Point Depression –-40 Degree Pressure Dew Point –Internalized filtration Proven customer track recordsProven customer track records

30 Finally..he says.. (Im almost done)(Im almost done)

31 Actual Installations…note sizesize installationsinstallations flexibilityflexibility

32 Shop Compressors

33 Concrete

34 Compact Installation

35

36

37 Would Like to Thank Dry Air Systems, Inc

38 Bottom Cap Die cast AluminumDie cast Aluminum Houses 2 valvesHouses 2 valves –Unloader, Inlet Houses heater assembly (opt.)Houses heater assembly (opt.) Two NPT portsTwo NPT ports –1/2 inlet, 3/8 UNL port One exhaust portOne exhaust port

39 MVP Adapter Plate Used to mount dryerUsed to mount dryer Houses check valveHouses check valve Separates contaminated airSeparates contaminated air Directs filtered, dried air to air systemDirects filtered, dried air to air system

40 Purge Valve #PV1 Viton Ball sealViton Ball seal Two Viton O ring sealsTwo Viton O ring seals Opens with governor air signalOpens with governor air signal Closes with spring ForceCloses with spring Force New Design

41 Regeneration Valve #RGV1 Positioned above safety valvePositioned above safety valve Two piece designTwo piece design –spindle and spring Controls regeneration cycle and purge rate during non pumping cycleControls regeneration cycle and purge rate during non pumping cycle Easily servicedEasily serviced 1/16 hole

42 Inlet Valve #IV1 Stops air flow from compressor during regeneration cycleStops air flow from compressor during regeneration cycle Utilizes Viton seat and two O ringsUtilizes Viton seat and two O rings

43 Heater Assembly (Optional) 75 watt heater75 watt heater Sealed with cover & RTV 205 Silicone (OLD)Sealed with cover & RTV 205 Silicone (OLD) SAE Two pin sealed connectorSAE Two pin sealed connector Thermostatically controlledThermostatically controlled 35 deg. F

44 Safety Valve PSI Full flow of 30 CFMFull flow of 30 CFM Mounted in intake manifold for easy accessMounted in intake manifold for easy access

45 Filters Primary filter captures larger particlesPrimary filter captures larger particles two additional filters on top and bottom of desiccant bedtwo additional filters on top and bottom of desiccant bed Desiccant bag retards oil contaminationDesiccant bag retards oil contamination

46 MVP-C1 Cartridge Outer Shell Constructed as a stamped steel shellConstructed as a stamped steel shell Mated to aluminum nut plateMated to aluminum nut plate Joined together with the stamped steel plated closing ringJoined together with the stamped steel plated closing ring

47 MV1-C1 Desiccant Spring Necessary to keeps desiccant under load during charge and regeneration cyclesNecessary to keeps desiccant under load during charge and regeneration cycles Necessary to prevent desiccant from pulverizingNecessary to prevent desiccant from pulverizing

48 Inner canister Constructed with Rynite Composite plasticConstructed with Rynite Composite plastic Holds 4 pounds desiccant, bag and two filtersHolds 4 pounds desiccant, bag and two filters

49 Desiccant Bag Contains four pounds of desiccantContains four pounds of desiccant Acts as filter for retarding oil contaminationActs as filter for retarding oil contamination

50 Desiccant Desiccant A substance that adsorbs and desorbs moisture from air.Desiccant A substance that adsorbs and desorbs moisture from air. Contains four pounds of desiccant.Contains four pounds of desiccant. Positioned in center of inner canister.Positioned in center of inner canister.

51 Filters Primary filter captures larger particlesPrimary filter captures larger particles two additional filters on top and bottom of desiccant bedtwo additional filters on top and bottom of desiccant bed Desiccant bag retards oil contaminationDesiccant bag retards oil contamination