Presentation is loading. Please wait.

HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground.

Similar presentations


Presentation on theme: "HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground."— Presentation transcript:

1 HYDRO CLICK SYSTEM

2 Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground water infiltration through concrete wall (at buried tanks) Currently used systems Tiles Coatings Concrete without further treatment Thermoplastic liners DEMANDS ON POTABLE WATER TANKS Potable Water Tanks – general Hydroclick system Installation References Limitations Approvals 2

3 Problem: Coating of potable water tanks Limited service life Contamination of potable water by detached particles POTABLE WATER TANKS - GENERAL Potable Water Tanks – general Hydroclick system Installation References Limitations Approvals 3

4 Problems caused by solvent water: Service life ? Maintenance ? Repair ? POTABLE WATER TANKS - GENERAL Potable Water Tanks – general Hydroclick system Installation References Limitations Approvals 4

5 Product approval acc. to KTW (for potable water) Raw material approval DVGW-W270 (for pot. water) No deposits on the tank wall Easy to clean – high pressure resistance (130bar) Good resistance against chlorination up to 3 ppm (0,5 ppm free chlorine resp. 0,3 ppm ClO2) Long service life (PE-pipes 50 years) Fast installation / shorter construction times! Ventilation gap avoids creation of aggressive condensates ADVANTAGES OF SYSTEM Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 5

6 extruded - calendared max. width: 2000mm thickness: 4mm material: PE80 blue RAL mm ~ 2000mm 50mm HYDRO CLICK HYDRO CLICK liner HYDRO CLICK HYDRO CLICK profile HYDRO CLICK SYSTEM Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 6

7 HYDRO CLICK HYDRO CLICK profile coextruded with PEHD-el layer Distance studs (height ~ 9mm) Click stud (adjusted to the Click profile) HYDRO CLICK SYSTEM Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 7

8 Protective film Perforation strip (on both sides 50mm) HYDRO CLICK SYSTEM Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 8

9 Easy installation: No extensive preparation before installation Tiles and coatings may be left in the tank if they are not loose Second chamber can be operated without special efforts (no dust or odours) INSTALLATION Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 9

10 Wall installation Step 1: Sheet with click-studs is clicked into the profile which is mechanically fixed to the wall INSTALLATION Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 10

11 Step 2: Second sheet is clicked into the profile Preparation of the welding area Wall installation INSTALLATION Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 11

12 Step 3: Extrusion welding DVS optimized Wall installation INSTALLATION Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 12

13 Ground-wall-transition INSTALLATION Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 13

14 Wall connection / Margin sections INSTALLATION EPDM bar Stainless steel bar Sealing strip Connection with PE sheet strip PE profile fixed Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 14

15 Drain section remains Wall-ground-transition with 45° chamfer INSTALLATION Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 15

16 Thermoformed elements Lining of columns INSTALLATION Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 16

17 Anchor element INSTALLATION Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 17

18 Project: Brig Switzerland REFERENCES / PROJECTS Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 18

19 Project: Vernate Switzerland REFERENCES / PROJECTS Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 19

20 Project: Leuggern Switzerland REFERENCES / PROJECTS Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 20

21 REFERENCES / PROJECTS Potable Water Tanks – general Hydro click system Installation References Limitations Approvals Project: Leuggern Switzerland 21

22 Project: Völkingen Germany REFERENCES / PROJECTS Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 22

23 Project: Oberschlierbach Austria REFERENCES / PROJECTS Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 23

24 REFERENCES / PROJECTS Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 24

25 System limitations of the HYDRO CLICK system Applicable up to a max. temperature change of 10 °C Max. application temperature: 30°C Not recommended for back pressure build up between concrete and liner Not UV resistant LIMITATIONS Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 25

26 APPROVALS Potable Water Tanks – general Hydro click system Installation References Limitations Approvals 26

27 AGRU Kunststofftechnik GmbH Ing.-Pesendorfer-Str. 31 A-4540 Bad Hall Austria / EU T +43 (0) F +43 (0) E Subject to errors of typesetting, misprints and modifications. Illustration are generic and for reference only! THANK YOU