1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C.

Similar presentations


Presentation on theme: "1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C."— Presentation transcript:

1 1/66 Rated Speed (m/s) Load (Kg) 63068080010001150127513501600 18002000 1.00 50m/16F 1.50/1.60 75m/24F 1.75 75m/24F Duty Table Max. group control: G8C GeN2 Regen

2 2/66 Shenling Governor Gen2 Machine (MOR) Controller NGSOK AES/AMS CSB Regen Drive Space saving, energy saving, environmental friendly and excellent ride quality GeN2 Regen

3 3/66 OTIS unique technology- Coated Steel Belt (CSB) 20% less in weight while 2-3 times life time Lubrication free Size: 30×3 & 60x3 Steel cords: 12 & 24 Cord diameter 1.67mm Breaking load: 32KN & 64KN GeN2 Regen Technology from helicopter (Sikorsky)

4 4/66 CSB makes GeN2 Regen machine much smaller Diameter of sheave:100mm Groove:3/5 Brake voltage:24V Insulation class: F Diameter of sheave:115mm Groove:5 Brake voltage:24V Insulation class: F Roped Machine Gen2 Machine GeN2 Regen

5 5/66 CSB monitor (RBI) – Resistance Based Inspection (RBI) for CSB – Dynamic inspection of CSB status – LED indication – Elevator level at nearest floor when failure inspected – REM interface – A component, not a tool GeN2 Regen CSB Monitor

6 6/66 GeN2 Regen OTIS GECB Controller board Motorola 32 bit CPU with 1M Flash memory. Rear time failure clinic automatically CAN BUS 2.0 communication CE Comply ESD to avoid jobsite damage Up to100 floors and 4m/s ESD: Electro-Static discharge

7 7/66 GeN2 Regen ACD2 MRL Controller and Drive 320W x1300H x 160D Controller OTIS energy regenerative drive CAN-bus communication Mini E&I Panel 210W x 540H x 90D E&I PanelDrive

8 8/66 OTIS Gen2 Machine Regenerative system Energy saving Up to Regen Principle GeN2 Regen OTIS Regenerative Drive +

9 9/66 NGSOK Door operator For Gen2 Regen and also for all other passenger elevators PM motor, energy saving VVVF controller Motor drive directly, no gearbox Disc motor, space saving Easier for installation Max. moving mass: 200kg Motor IP: 44 GeN2 Regen Key parameters: –Side opening is availble OP=900~1300 – Standard opening height:2100/2000

10 10/66 GeN2 Regen Safety Components E3 Qualified Safety Gear – Otis US design qualification – Otis US MFG process control – Otis US change control – Reliable – Durable – Traceability Component OTIS E3 RequirementsEN81-1 Requirements Safety Gear25 freefall and runaway test4 freefall test Speed Governor25 Continuous tripping20 Continuous tripping Buffer100 strike test6 strike test Speed governor Comparison Oil buffer

11 11/66 Excellent Performance Data System performance Gen2 Regen (Belted, gearless) Traditional lift (Roped geared) X- Vibration A95 (mg) 9 11 Y- Vibration A95 (mg) 9 11 Z- Vibration A95 (mg) 1 14 Speed Tolerance (%) (@+10%V Rate, +1%f Rate, T max 40 ) +3+3+5+5 Maximum Acceleration( m/s 2 ) (@ start and stop) 1.2 Maximum Jerk ( m/s 3 ) (@ running) 1.0 Noise (dB) (@ Machine room) 72 75 Noise (dB) (@ In car, w/o fan, running ) 53 53 53 53 Level accuracy (mm) (@+7%V Rate, +1%f Rate, T max 40 ) Typical: ±3 Max. : ±5 ±5 GeN2 Regen