Presentation is loading. Please wait.

Presentation is loading. Please wait.

Dynamic Flow Computers Product Presentation. MAIN OFFICE HOUSTON, TEXAS BRANCH OFFICE CALGARY, CANADA BRANCH OFFICE UNITED ARAB EMIRATES MIDDLE EAST &

Similar presentations


Presentation on theme: "Dynamic Flow Computers Product Presentation. MAIN OFFICE HOUSTON, TEXAS BRANCH OFFICE CALGARY, CANADA BRANCH OFFICE UNITED ARAB EMIRATES MIDDLE EAST &"— Presentation transcript:

1 Dynamic Flow Computers Product Presentation

2 MAIN OFFICE HOUSTON, TEXAS BRANCH OFFICE CALGARY, CANADA BRANCH OFFICE UNITED ARAB EMIRATES MIDDLE EAST & ASIA BRANCH OFFICE MEXICO D.F., MEXICO MEXICO & SOUTH AMERICA OFFICE & SERVICE CENTER SAUDI ARABIA Dynamic Offices

3 Company History Founders at Elliott Flow Computers Dynamic Flow Computers Established in Focused on Liquid Markets Micro MV E Chart E Chart Plus E Chart Lite 1998-Present Focus on both Liquid & Gas markets

4 Mission Statement The objective of DFC is to provide you with the latest in state of the art Electronic Flow Measurement with a total commitment to quality in products and service.

5 Over the years we have strived to bring the latest advances in technology to the flow computer industry Some examples: Wireless Bluetooth Communications. Memory Stick Walk-by SCADA. Fieldbus Foundation Protocol. Graphical Trend Screens. First field-mounted liquid flow computer. Latest Technology

6 API 14.3 OR AGA 3 – (Differential orifice, Cone, etc) AGA 7 (Frequency such as Turbine, PD, and Others) AGA 8 Compressibility (Gross & Detail Methods) API 21.1 & 21.2 EFM Standards API Liquid Algorithms Other Specific Applications Available Flow Measurement Standards

7 Temperature rating -40 to +185 °F PID & Boolean Logic Math Functions Low Power (Only 0.5 Watts) 35 to 55 days of data Storage 4 Line by 20 Character Display User configurable scrolling display with display freeze option Infra red sensors for easy configuration & calibration Gas or Liquid Class 1, Division 1 Up to Four Meter Runs Touch Screen with A Level Security Built in UPS for days of operation Built in Rosemount 205 for Pressure, Temperature, & DP MicroMV

8 Gas and Liquid Class 1, Division 1 2 Digital Outputs 1 Digital/Frequency Input 2 Analog Inputs One RS232 and One RS 232/ Bit Analog Output Graphical Display Built in Rosemount Multivariable 205 Temperature rating -40 to +185 °F PID, Boolean Logic, & Math function Meets API 21.1 for Custody Transfer 64 days of Data Storage Low Power Solar Options Battery & Enclosure temperature built-in DISPLAY 8 Lines of Text Graphical Trend Display User Configurable Display Min / Max Trending

9 The Most Accurate and Reliable on the Market. Exclusive Dynamic-Rosemount agreement. Accuracy is +0.1% standard or % optional. Measures static, differential pressure, and temperature Rosemount co-planar flange for easy installation. High stability design means less calibration. SPECIFICATIONS Pressure Ranges: PSIG or PSIG DP Ranges: 0-25, or Bi-Directional Inches of Water RTD plugs in to the 205 module directly with a Temp range up to 1200 F Update time of 108 mS Rosemount Multivariable

10 Typical Field Installation

11

12 HAZARDOUS AREA GENERAL PURPOSE AREA FLOW COMPUTERS CAN BE DIRECT MOUNTED OR MOUNTED ON A 2 POLE Additional MV/EChart w/ Transmitters and with or without Display Multiple Run Installation

13 Our standard communication ports let us integrate with all the current communication media. And now we also support the latest Bluetooth Wireless protocol Built-in Communications

14 On Site ECHART to Micro MV in 10 Minutes 1 Meter run up to four meter runs using MV & EChart or 3095 Multi-variable Transmitters Well Optimization PID & Logic Control Inputs / Outputs

15 Nine 24-Bit analog channels per MV with 3 additional MV slave units for I/O expansion (21 analog) 3 frequency channels with three additional MV slave units for I/O expansion (12 channels) 4 analog outputs with 3 additional MV slave units expansion (7 analog out) 3 digital inputs or outputs with three additional MV expansion (9 digitals) 3 Communication ports Up to 4 meter runs in one MV device. Mixture of liquid and gas algorithms corrected to 15°C or 60°F (metric or US units) Slave I/O module when only 1 meter run MicroMV Field IO & Expansion

16 Windows & DOS Configuration Software On site Configuration Remote Configuration Modbus Master & Slave (ASCII or RTU) Data Storage & Retrieval Data Displayed & Collected via PDA, Laptop, Radio, Cell, or Satellite Low Power Data Management

17 Each history point is configured to archive the current value, average value, totalized value, and accumulated value days of data storage that includes calculated values including Min./Max. values, minute, hourly, hourly, and daily values One Year of Monthly Data is also Stored Historical Data

18 The Event Log records the last 200 parameter changes The Alarm Log records the last 200 occurrences of alarms The logs can be viewed, saved, printed, or transmitted Alarms & Logs for the four Meter Runs are stored when using the four meter run option Event & Alarm Logs

19 Report By Exception Allows Cry out Allows the Flow Computer to report any Alarms to the Host system Report by Exception

20 All Final Assembly & Testing is done in Houston, Texas. CPU Boards are made in Canada, Housing by Adalet, and Transmitters by Rosemount USA. Units are tested in an environmental chamber for 72 hours and bench tested for a 2 week period prior to shipping. Manufacturing Facility

21 Dynamic worldwide offices & agents/representatives are key sales support Dynamic Flow Computers are standard units, available in stock at all times, and ready for shipment within hours, days, or weeks depending on quantities and customer request. Dynamic has a training program that can be given at our facility or on site. Sales & Support

22 Dynamic Flow Computers are easy to use and easy to maintain. Tundra Controls, Syntech EnerflexIn Canada Service support is performed by Tundra Controls, Syntech Enerflex, Bentek Systems, Pro-Logic Controls, or by Dynamic technicians upon request. Service requests are dealt with immediately by Tundra and Syntech through their various 24 / 7 support centers. Dynamic Mfg./Service facility in Calgary, AB Service

23 Future Products 10 Times more processing power. Built-in Ethernet and USB: Even more communications alternatives. The REAL Smart I/O: Interchangeable I/O Modules provide a wide range of Input / Output configuration options. Advanced Diagnostics including our renowned Turbine Diagnostic. Redundancy and Smart I/O capabilities: Multiple SuperMVs in a single network can act as separate units, extended smart I/O, or 100% redundant systems. Modbus & Foundation Fieldbus compatible communication Multiple API, AGA, and ISO equations are programmed into each unit. Dynacom software with user friendly interface for PCs and Handhelds

24 Upstream Measures Key production metrics Oil Steam CO2 Gas Water

25 Test Separator Report

26 Typical Upstream Installation Flow Meter Flow Computer Solar Panel Comm. Package

27 Midstream Pipeline Metering Meter Proving Tank Levels Custody Transfer Sends data back via SCADA to control rooms Measures Pipeline Operation

28 Prover Report

29 Batch Report

30 Typical Midstream Installation Flow computer Sampler Tank Levels Flow computer

31 Downstream Refinery Inputs (Oil, Gas) Outputs (Refined Prod.) Steam Energy (BTUs) Helps Measure Plant Efficiency (Outputs- Inputs)

32 Bi-directional Volume Report Bi-Directional Report

33 Typical Downstream Installation Multiple Meter Runs Flow Computers Data goes To Control Room Additional Equipment: -Densitometers -Chromatographs -Etc.

34 Installation Pictures

35

36

37

38

39

40

41 Installations

42 SONATRACH Algeria SAUDI ARAMCO Saudi Arabia KUWAIT OIL COMPANY Kuwait TEXACO PIPELINE USA MOTIVA USA Husky Energy Canada PEMEX Mexico ZETA GAS LPG Peru ATLANTIC LNG Trinidad AL FANAR PETROLEUM Egypt Chevron/Enerpro Canada Petro-Canada Canada CONOCO-PHILLIPS USA Shell USA Apache Canada BP-AMOCO USA CHEVRON-TEXACO USA EXXON-MOBIL USA Select Dynamic Users

43


Download ppt "Dynamic Flow Computers Product Presentation. MAIN OFFICE HOUSTON, TEXAS BRANCH OFFICE CALGARY, CANADA BRANCH OFFICE UNITED ARAB EMIRATES MIDDLE EAST &"

Similar presentations