1 HMIs Human Machine Interfaces HMIs

2 HMIs Human Machine Interfaces MP+ Terminals Future TCP / IP TCP / IP

3 HMIs E710 E700 E900 E910 E300 E200 E100 E600 E900VT The E-series of HMIs E50

4 HMIs E50 - low cost Background lit text display 2x16 4 function keys RS422 with RS232 in the same Dsub +5 VDC, external or from PLC Text blocks

5 HMIs E100 - small but strong Background lit text LCD-display 2 rows x 20 characters 4 function keys Text blocks Time channels Real-time clock Recipe handling RS-232C and RS-422 ports +5 VDC, external or from PLC 64 Kbytes flash memory Transparent mode HMI Tools support

6 HMIs E200 - As simple as it can be Background lit text LCD-display 4 rows x 20 characters, 5 mm text height 5 function keys 5 LEDs (two colour) Text blocks Time channels Real-time clock Recipe handling RS-232C and RS-422 ports 64 Kbytes flash memory Transparent mode HMI Tools support

7 HMIs E300 - Low-end graphic Background lit graphic LCD-display Two colours, 240 x 128 pixels 8 function keys 16 LEDs (two colour) Graphic and text blocks Time channels Real time trends Recipe handling RS-232C and RS-422 ports 1 expansion slot 128 Kbytes Flash memory, expandable to 8Mb Transparent mode HMI Tools and TCP/IP support

8 HMIs E600 - one step up Background lit graphic LCD-display Two colours, 240 x 128 pixels 16 function keys 16 LEDs (two colour) Graphic and text blocks Functionality as E300 Historical trends RS-232C and RS-422 ports 1 expansion slot 256 Kbytes Flash memory, expandable to 8Mb Transparent mode HMI Tools and TCP/IP support

9 HMIs E700 - A trend composer Background lit graphic LCD-display 256 colours, 320 x 240 pixels 16 function keys 14 LEDs (two colour) Graphic and text blocks Functionality as E600 RS-232C and RS-422 ports 2 expansion slots 400 Kbytes Flash memory, expandable to 8Mb Transparent mode HMI Tools support and TCP/IP support

10 HMIs E710 - with new hardware Background lit graphic touch LCD-display 256 colours, 320 x 240 pixels 8 function keys 8 LEDs (two color) Graphic and text blocks Functionality as E700 RS-232C and RS-422 ports 2 expansion slots 400 Kbytes Flash memory, expandable to 8Mb Transparent mode HMI Tools support and TCP/IP support

11 HMIs E900 - Even bigger Background lit graphic colour display 256 colours TFT, 640 x 480 pixels 22 function keys 20 LEDs (two colour) RS-232C and RS-422 ports 2 expansion slots 1.6 Mbytes Flash memory, expandable to 8Mb 220 VAC power supply Transparent mode HMI Tools and TCP/IP support

12 HMIs E910 - touch it! Background lit graphic touch display 256 colours TFT, 10,4, 640 x 480 pixels RS-232C and RS-422 ports 2 expansion slots 1.6 Mbytes Flash memory, expandable to 8Mb Dimensions 290 x 250 x 105 mm 220 VAC power supply Functionality as E900 24VDC version now available!

13 HMIs E900VT - more inputs... Background lit graphic TFT-display 256 colours, 10,4, 640 x 480 pixel 22 + 28 function keys ( IFC-64E ) 20 two color + 28 green LEDs RS-232C and RS-422 ports 1 expansion slot 1.6 Mbytes Flash memory, expandable to 8Mb 220 VAC power supply Functionality as the E900

14 HMIs E610 - preliminary Touchversion of E600 B/W LCD display Compact Low price Release Q4 2000

15 HMIs Expansion cards Memory expansion with IFC-MC Increase project memory with up to 8Mb Back-up of recipes and projects Transfer of files to other terminals Profibus DP IFC-PBDP Slave connection to Profibus DP TCP/IP network IFC-ETTP, IFC-ETCX Terminal network and Internet enable via Ethernet

16 HMIs Expansion cards External function keys with IFC-128E For connection of up to 128 extra function-keys Parallel printer with IFC-PI For connection of an parallel printer A-bus interface IFC-GA (E900/E910 only) Direct connection to the A-bus

17 HMIs IFC-PI - Parallel printer port Print outs of graphic and text blocks, reports and alarm lists –Graphics requires a HP PCL5, HP PCL6 or Epson FX80 compatible printer –If IFC PI is used a printer can not be connected to the RS- 232 port E300 and E600 have no support for HP PCL5/6 printers Black and white print outs only

18 HMIs IFC-PI - Parallel printer port Connectable to –E300 version 4.0 or higher (only with Epson FX-80) –E600 version 4.02 or higher (only with Epson FX-80) –E700 version 4.0 or higher –E710 version 4.0 or higher –E900 version 1.01 or higher –E910 version 4.02 or higher

19 HMIs IFC-GA - Direct bus connection With the expansion card, IFC-GA, and the bus- interface A7GT-BUS installed, you can connect the E900 and E910 terminals directly to the base unit on an A(nS)-system. The communication between the PLC and the terminal will be very effective with the IFC-GA, because the terminal communicates directly with the A-bus on the PLC. The standard RS-232/422 ports will be free for other equipment.

20 HMIs Before: Today: Omron.dll Omron.hlp Omron.pdf Terminal code + Drivers Project Terminal code Driver Project The new concept

21 HMIsWEB The new concept Downloadable drivers All terminals in the E series from version 4.0 The driver and the system program are separated in the terminal New drivers can be used without a update of MP+ Installation via Internet using MP+ or from floppy (first download from web) Current driver is automatically transferred to the terminal by MP+ New standard cables to new PLC systems Manual in pdf-format to each driver

22 HMIs 2 ports gives you freedom Transparent mode Communication with the PLC system via the terminal Mitsubishi Omron Matsushita No protocol mode - Communication with external units i.e. barcode readers Serial printer

23 HMIs GPP/WIN MM+ Transparent mode Reach PLC through terminal in operation Online changes Easier troubleshooting

24 HMIs Individual customised products - from simple panels to PC platforms Integration into your machine design Customised OEM products, your operator control concept in style and functionality What can we offer you: Individual design and front layout Modular Hardware Flexible Software We will implement your requirements - So You can be successfully in business Professionalism and competence is our name And You: Be an individual... Are you an individual?

25 HMIs The lifecycle - Of a terminal... Even at the design stage we try to think in a long time perspective The choose of : –Components –Material Recycled Recycling –Handling –Transports Minimum And in the end... We take care of old used products, and sees that every part is handled in a minimum non-polluting way. As our contribution to the environment.

26 HMIs The usual information way RUN STOP FWD REV Operator Process/ Machine Process/ Machine Do it the hard way...

27 HMIs HMI Or the easy way! HMI as information provider! The HMI-solution gives you: Information in a easy way The Information will be clear and in right time Easier to determine when changes occur Process/ Machine Process/ Machine Operator

28 HMIs You will save: Money Effective Flexible Simplicity Time Easy - Handle Quick - Learn Simple - Install Right information - In Right Time

29 HMIs Basic functions Alarm handling Recipe handling Realtime clock Time channels Trend diagram Password handling

30 HMIs Operator interface Text Graphic Colors Touch screen LEDs Functionkeys Printouts

31 HMIs Mac Programmer+ Easy to use Windows 95, 98, 2000 and NT Documentation Back-up Full support for Windows copy/paste Toolbox and ToolTips Multiple project can be open at the same time Compatible name list with MELSEC MEDOC and MELSEC MEDOC + Support for MXChange

32 HMIs Structure Using a tree structure when developing a project

33 HMIs Block manager Simplifying the handling of the blocks. Gives the engineer a visual overview how the project is created.

34 HMIs Object based All object data is stored in the terminal The signals is configured directly in the object No PLC-programming is needed* Only the object´s which is viewed on the screen is updated * except Profibus

35 HMIs Downloadable drivers Now you are just a click from upgrading your drivers

36 HMIs The Internal Name list For easy changing of different PLC devices

37 HMIs Message library Manoeuvrable message objects –64 libraries can be manoeuvrable with 512 texts, 40 characters –Values between 0-65535 can be linked with texts

38 HMIs News in Mac Programmer+ 32-bit version to Windows 95, 98, 2000 and NT Supporting downloadable drivers Supporting TCP/IP network Installation from CD

39 HMIs News in Mac Programmer+ New configuration of peripheral units Acknowledge of individual alarms from the PLC system Alarm on the negative edge

40 HMIs More news! Modem handling in all terminals except E50 –Call up with the terminal –10 different numbers stored in the terminal –1 number stored in the PLC system Larger size on the alarm text in E900 System monitor in E700, E710, E900 and E910

41 HMIs More news! Show terminal in text blocks Printing text strips to all terminals from MP+ Improved project documentation in print-outs Use terminal font in MP+ Cursor colour in the alarm list can be changed

42 HMIs And more…. Recipes sorted in alphabetic order Turning off printing from the PLC system to avoid conflicts when transparent mode is used Min- and max limits on numeric objects in graphic blocks The alarm group name can contain national characters New data formats –HEX 16-bit, 32-bit –BCD 16-bit, 32-bit –Float without exponent

43 HMIs The Installation CD MAC Programmer+ 32-bit HMI Tools 32-bit All current drivers Manuals to all products –E-series and MAC-series –Expansion cards –Installation manuals –Drivers Floppy-copying of Full version, Demo and Transfer

44 HMIs New manuals New E-series manual –The same manual to all E-terminals and MP+ New installation manual –The same manual to all E-terminals –Enclosed with all terminals Separate manual to each driver –Downloaded with the driver in MP+ All pdf-manuals are available at WEB-site and on installation CD

45 HMIs HMI Tools Windows 95, 98, 2000 and NT Transferring of recipes, trends and alarm lists Downloading of system programs Communication via modem MP+ Transfer is a separate program

46 HMIs Why choose an operator terminal from Mitsubishi? High Quality User friendly Functionality One Software for all terminals Possibility to upgrade the operating system High quality support And of course the openness

47 HMIshttp://www.mitsubishi.co.uk/automationhttp://www.e-terminals.com Support at the web Downloadable: Latest versions of software's Demo Projects Product news Drivers Manuals Manufacturer´s declarations Upcoming features Application examples FAQ

48 HMIs The Open Concept Drivers & Connections

49 HMIs Drivers Melsec A (C24*, CPU, E71** or Profibus DP**) Melsec A-bus (A-bus*) Melsec A CC-Link connection (AJ65BT-G4) Melsec FX (CPU or 485ADP*) Melsec QnA (QC24*, QCPU* or Profibus DP**) Freqrol FR-A/E Melservo MRJ2CS100 * Can not be used with E50 ** Can not be used with E50, E100 or E200

50 HMIs Drivers SIMATIC S5 (3964R/RK512*, PG-port* or Profibus DP**) SIMATIC S7 (3964R/RK512*, MPI*, PPI or Profibus DP**) * Can not be used with E50 ** Can not be used with E50, E100 or E200

51 HMIs Drivers ABB –SattCon (Comli master*) Allen-Bradley –Micrologix (DF1) –SLC500 (DF1 or DH485**) Control Techniques –Unidrive (ANSI*) Delta Tau –PMAC, UMAC (ASCII*) Demonstration driver –Internal in the HMI DVT Vision System –SmartImage Sensor (ASCII or TCP/IP**) Festo/Beck –IPC, FEC series (FXT CI*) GE Fanuc –Series 90 (SNPX) Hitachi –H Series (HCOM*) IAI –SuperSEL (Serial*) * Can not be used with E50 ** Can not be used with E50, E100 or E200

52 HMIs Drivers Idec –FA-1/2/Junior/Micro1 (FA- series 1:1 expanded*) –FA-3 (FA series 1:1*) –MICRO3/3C (Micro Computer Link) Klockner Moeller –PS4 series (SUCOM-A*) Koyo –Direct logic series (DirectNET* or K-sequence) Matsushita –FP-series (MEWTOCOL- COM) Modicon –All PLC types (Modbus master ASCII/RTU or Modbus slave RTU*) MXCC –VLC (Serial* or Profibus DP**) Omron –All PLC types (Hostlink) * Can not be used with E50 ** Can not be used with E50, E100 or E200

53 HMIs Drives SAIA –PCD series (SBUS*) SEW Eurodrive –Movidrive (Movilink*) –Movidyn (Movidyn*) –Movitrac (Movitrac*) Telemecanique –TSK series (UniTelway*) Toshiba –PROSEC T-series (Computer Link) VT100 Yaskawa –MP9xx series (MemoBus master RTU*) * Can not be used with E50 ** Can not be used with E50, E100 or E200 … and more will come!

54 HMIs How to make a connection

55 HMIs TCP/IP or UDP/IP BDTP PLC-program E71-profile IFC-ETCX Server Client Client Mitsubishi - E71 driver The PLC-systems in Melsec A/QnA(S)-series via AJ71E71 or AJ71QE71 using the ASCII protocol. All E-series terminals can be used, with the exception of E100 and E200. Requires Ethernet card.

56 HMIs Mitsubishi - MELSERVO All E-series terminals can be used MR-J2-C-S100 RS422 or RS232 connection Multidrop of up to 32 servos possible Read/Write all inverter parameters, digital/analog signals, alarm codes All E-series functionality available (text/graphic, trending, recipe, reporting, networking …)

57 HMIs Point-to-point Multidrop RS-485 RS-422 RS-232 Default station number Mitsubishi - MELSERVO Cable as drawing in the manual

58 HMIs FREQROL FR-A/FR-E All E-series terminals can be used FR-A and FR-E series RS422 or RS232 connection Multidrop of up to 32 inverters possible Read/Write all inverter parameters, digital/analog signals, alarm codes All E-series functionality available (text/graphic, trending, recipe, reporting, networking …)

59 HMIs FREQROL FR-A/FR-E Cable as drawing in the manual Point-to-point Multidrop Default station number RS-422 PU-Port FR-A5NR CAB-9 PU-Port SC-FRPC RS-422 RS-232 RJ45

60 HMIs MXCC E-series alt.1 PROFIBUS-DP connection E300-900 can be connected MXCC-program handles the HMI-profile

61 HMIs RS232 I/O-bus MXCC E-series alt. 2 Serial connection MXCC-program (Profile) All E-series HMIs can be used Low price connection Survives NT-crash Terminal network through Ethernet possible

62 HMIs Cable as drawing in the manual ABB - COMLI Master Supports multidrop RS-422 RS-485 Nod ID: CAB-8 CAB8

63 HMIs Allen-Bradley DF1 Micrologix The PLC-systems in the Micrologix 1000-series CAB-2 RS-232 This node = Terminal Remote node = PLC CRC-16 checksum Full duplex 8-pol Mini-Din

64 HMIs Allen-Bradley DF1 SLC-500 The PLC-systems SLC 500, SLC 5/01, SLC 5/02, SLC 5/03 and SLC 5/04 Requires the module 1747-KE, 700 DEM (The DF1 connection at SLC 5/03 and SLC 5/04 is not recommended because of more disturbance) CAB-5 RS-232 This node = Terminal Remote node = PLC CRC-16 checksum Full duplex Cable 1747-C13 from Allen-Bradley DH-485

65 HMIs Control Technique - UNIDRIVE All E-series terminals can be used Inverters in the Unidrive series with serial interface i. e. UD 71. RS422 or RS232 connection Multidrop of up to 32 servos possible Read/Write all controllers parameters, digital/analog signals, alarm codes All E-series functionality available (text/graphic, trending, recipe, reporting, networking …)

66 HMIs Point-to-point Multidrop Default station number RS-422 RS-485 CAB-8 CAB8 RS-422 2-wire 4-wire RS-422 Control Technique - UNIDRIVE Cable as drawing in the manual

67 HMIs Delta Tau - PMAC/UMAC All E-series terminals can be used RS422 or RS232 connection Point to Point or Multidrop Read/Write all controllers parameters, digital/analog signals, alarm codes All E-series functionality available (text/graphic, trending, recipe, reporting, networking …)

68 HMIs MAC 40+-CAB RS-422 Default station number Multidrop is performed by a band cable between the PMAC/UMAC systems Delta Tau - PMAC/UMAC The Positioning-system in Delta Tau PMAC/UMAC- series

69 HMIs Demonstration driver Driver for demonstration without PLC-system 99 M-coils 99 data registers 4 counters 4 timers

70 HMIs GE Fanuc SNPX The terminals supports all GE Fanuc PLC systems, connected via the SNPX protocol. RS-422 CAB-4 SNP ID number No PLC-program requires for the communication

71 HMIs RS-422 Idec 8-pol connector RJ11 RS-422 Contain electronically devices, se driver manual Idec - FA series The PLC-systems in Idec FA-series Cable as drawing in the manual

72 HMIs RS-422 RS-232 8-pol Mini- din 8-pol Mini- din Default station number RS-485 CAB-8 CAB8 I Alt. I Idec - Micro 3-series The PLC-systems in Idec Micro 3-series Cable as drawing in the manual

73 HMIs RS-422 RS-232 15-pol RJ12 Default station number Koyo - DirecNet & K-Sequence Koyo Direct Logic Series K-Sequence PLC Koyo via the DirectNET Cable as drawing in the manual

74 HMIs RS-422 RS-232 15-pol 9-pol 5-pol Mini-Din Default station number Matsushita - FP series The PLC-systems in Matsushita FP-series via the MEWTOCOL-COM protocol Cable as drawing in the manual

75 HMIs Modbus ASCII / RTU Supports Multidrop RS-422 RS-485 CAB-8 CAB8 Default station number Cable as drawing in the manual

76 HMIs Omron Hostlink The terminals supports all Omron PLC systems, connected via the Hostlink protocol. Supports transparent mode CAB-3 RS-232 No PLC-program requires for the communication Default station number

77 HMIs Siemens SIMATIC S5 PG1/AS511 The PLC-systems SIMATIC S5 90, 115, 135 and 155 No PLC-program requires for the communication CAB-7 CAB-1 Siemens Converter 6ES5 734-1BD20 RS-232 RS-422

78 HMIs Siemens SIMATIC S5 3964R/RK512 The PLC-systems SIMATIC S5 90, 115, 135 and 155 Requires communication card CP525 Writing is only possible to DB, other devices can only be read CAB-6 CAB-5 RS-232 RS-422 Null modem The terminal Higher priority=Master PLC 3964R / RK512=Slave

79 HMIs Siemens SIMATIC S5 Profibus DP The PLC-systems SIMATIC S5 90, 115, 135 and 155 Requires Profibus DP interface (IFC-PBDP) IFC-PBDP PLC program HMI-profile Requires timedelay in connection with fast CPU:s

80 HMIs Siemens SIMATIC S7 MPI The PLC-systems SIMATIC S7 300- and 400-series CAB-6 CAB-5 RS-232 The MPI station number of the terminal The MPI stationnumber of the PLC system Highest MPI address RS-422 + CAB-11

81 HMIs Siemens SIMATIC S7 PPI The PLC-systems SIMATIC S7 200-series Cable as drawing in the manual CAB-8 RS-422 The station number of the terminal The stationnumber of the PLC-system Highest PPI address Only the terminal can be Master in the network PPI-Port

82 HMIs Siemens SIMATIC S7 3964R/RK512 The PLC-systems SIMATIC S7 300- and 400-series Requires communication card CP341 Writing is only possible to DB, other devices can only be read CAB-5 RS-232 The terminal Higher priority Master PLC 3964R/RK512 Slave

83 HMIs Siemens SIMATIC S7 Profibus DP The PLC-systems SIMATIC S7 300- and 400-series Requires Profibus DP interface (IFC-PBDP) IFC-PBDP PLC-program HMI-profile

84 HMIs Toshiba The PLC-systems in PROSEC T-series via Multidrop connection Cable as drawing in the manual MAC30/40-CAB RS-422 CR-01 The Computer Link protocol RS-485 RS-232 RS-485 CR-01 Default station number

85 HMIs Cables CAB1 –cable to connect Siemens SIMATIC S5/PG1 via Siemens Converter to the RS-232-port on the terminals in the E-series. 0,5 m. CAB2 –cable to connect Allen-Bradley's PLC system Micrologix to the RS-232-port on the terminals in the E-series. 3 m. CAB3 –cable to connect Omron PLC system via the Hostlink protocol to the RS-232-port on the terminals in the E-series. 3 m.

86 HMIs Cables CAB4 –cable to connect GE Fanuc PLC system via the SNPX protocol to the RS-422-port on the terminals in the E-series. 3 m. CAB5 –cable to connect Siemens SIMATIC S7/MPI via Siemens HMI Adapter, Siemens SIMATIC S7/3964R, Siemens SIMATIC S5/3964R and Allen-Bradley/DF1 PLC-systems to the RS-232- port on the terminals in the E-series and to connect a PC to the RS-232-port on the terminals in the E-series. (MAC PROG/9-CAB) 3 m.

87 HMIs Cables CAB6 –cable to connect Siemens SIMATIC S7/MPI via Siemens HMI Adapter, Siemens SIMATIC S5/3964R and PC to the RS-422-port on the terminals in the E-series. 3 m. CAB7 –cable to connect Siemens SIMATIC S5/PG1 straight to the RS-422-port on the terminals in the E-series. 3 m.

88 HMIs Cables CAB8 –to connect the terminals in the E-series to PLC- systems via RS-485. Adapter placed on the RS- 422-port at the terminals. CAB9 –cable to connect Mitsubishi Fr-A / E inverters straight to the RS-422-port on the terminals in the E-series. 3 m.

89 HMIs 2 serial ports gives you freedom Transparent mode –Communication with the PLC system via the terminal, online No protocol mode –Communication with external units Serial Printer –Communication with a serial printer

90 HMIs Message packet The Communication Point to point, master/slave –Terminal read/write information. –PLC replys on requested information. Signals which effects the communication time –Overhead signals except signals in the current block. –alarms, trends, display-signals, LED-registers, block-prints, index, register for PLC-watch etc.

91 HMIs The Communication Signals which NOT effects the communication time –Signals connected to function –keys, time channels, objects in alarm texts. Effective communication = (as few message packets as possible) –Group signals. –Dont dump the watch with to short interval. –Block change with display register. –Packaging of signals (consecutive order). Message packet

92 HMIs The future requires new concepts New concepts reach new markets - new markets gives us new customers Openness is one key to the future More effective development work Even higher quality

93 HMIs Internet technology More openness PC-based HMI functionality Windows CE More efficient tools Internet technology More openness PC-based HMI functionality Windows CE More efficient tools High functionality Easy handling Optimized for Mitsubishi Electric products High functionality Easy handling Optimized for Mitsubishi Electric products The HMI strategy

94 HMIs * Supervisory connectivity - Remote HMI/PLC process monitoring/control - Diagnostics - Statistic reporting - Internet connection - Data file exchange * Plant floor connectivity - All major PLC:s - PC-based control systems - Fieldbuses - Local networks * Flexible HMI application - Data exchange with Word, VB, Excel. - Reuse of objects - More options for advanced users * OPEN STANDARDS ! - TCP/IP-Ethernet. - Windows CE/NT/95 - OPC, ActiveX, COM/DCOM - Internet technology Future customer requirements

95 HMIs Product hierarchy CEZAR SCADA system Operator terminals - Graphic - Text

96 HMIs CEZAR concept Microsoft ® Windows NT ® Windows NT ® Microsoft ® Windows CE ® Windows CE ® C-terminals Adaptions for NT / NT-E / CE environment Same concept-different platforms Desktop Adaptions for NT environment

97 HMIs CEZAR concept The CEZAR-RT and the CEZAR software will check if all the necessary components exist on the target platform. If not, they will be distributed automatically by the software. CEZAR Developing tool *The Terminal Client Application must be purchased separate CEZAR-RT ( TCA ) C-Terminal Any PC The Terminal Client Application is always included in the C-terminals CEZAR-RT ( TCA* )

98 HMIs Basic functions Alarm handling Recipe handling Real-time clock Time channels Trend diagrams Password handling

99 HMIs 125º Operator interface Text Graphic/Pictures Colours Touch screen Print-outs Possibility to start other Windows applications

100 HMIs 3. Enterprise 2. Professional 1. Basic CEZAR developing tool Three selectable user levels: Event driven programming (level 2-3) Programming with Visual Basic-script (level 3) Drag n Drop ActiveX controls Copy/Paste from Windows

101 HMIs Improved HMI functionality (1) Data exchange with... Script language using… Extended character support - Unicode - True Type Fonts Multimedia support - Video - Sound

102 HMIs Improved HMI functionality (2) Internet access –Web Server - Allow access from other sites –Web Client - Get data from other sites Network possibilities –Distributed objects –Shared data files (alarm list, application) –Network with NT-stations

103 HMIs Open system Microsoft technology: –OPC - allows for 3.rd party drivers –COM/ActiveX - object component base –DCOM - distributed objects Objects based: –Object accessible from external applications –Reuse of objects –Customer can create new objects

104 HMIs CEZAR Connections USB-Ports 2 x USB Ethernet-Port TP with RJ45 Parallell-Port Serial-Ports 1 x RS422 2 x RS232 Support for Multiple drivers How many inputs do You have?

105 HMIs Microsoft ® Windows NT ® Windows NT ® Hardware specification NT (1) Intel/Pentium MMX 266 processor 12.1 Touch TFT display, 800*600, 256 K colours C&T 69000, 2MB SDRAM video Chips 64 MB RAM memory, expandable to 128 MB 6.1 GB hard drive, 2.5", EIDE 2 x USB ports 2 x RS-232 ports RS-422

106 HMIs Hardware specification NT (2) Parallel port Ethernet TP 100M, RJ-45 connector 32 bit PCI slot, 2 brackets 2 x 16 bit PC104 slot, stacked Keyboard, Mouse and sound* connectors Microsoft ® Windows NT ® Windows NT ® * Optional

107 HMIs Future developments

108 HMIs Development areas More E-series drivers will still come Strengthen low-end area of E-series EX classified environment Integration of Internet-technology Use the benefits from Windows CE and NT And...

109 HMIs The HMI WEB

110 HMIs BDTP Server Client Server/Client Overview TCP/IP network Functionality –Terminal network, replacing MAC network, 10Mbit/s –Transfer data between PLC-systems –Project transfer –More will come... Connection possibilities –Ethernet Twisted Pair or coaxial –Serial New expansion cards –IFC ETTP, Twisted Pair –IFC ETCX, Coaxial

111 HMIs Overview TCP/IP network - twisted pair IFC ETTP in each terminal Maximum length between terminal and HUB is 100 m Twisted pair CAT5, shielded or not shielded RJ45 connector The number of connections on the HUB settles the maximum number of terminals connected to each HUB No HUB if only two terminals

112 HMIsSegment Overview TCP/IP network - coaxial cable IFC ETCX in each terminal Maximum length on each segment is 185 m Maximum 30 units on each segment Maximum 5 segments can be connected via repeaters and maximum 3 segments can have units Coaxial cable RG58 Termination 50

113 HMIs BDTP improvements in version 5 Server Alarms –- Define the alarm in the server, this will be sent to all the clients automatically when the signal is activated. RAS* functionality –Automatic restart of clients when server restart. * Recovery Automatically System

114 HMIs Available now! TCP/IP - step 2 Intranet / Internet connection Remote monitoring/Maneuvering –Via web-sites –Free Browser Data transfer –FTP transfer E-mail –SMTP

115 HMIs Local connections Intranet –Local factory network –Good response time –Local domains Call-up Intranet –World-wide access –Good response time –Local domains

116 HMIs W.W.W. Global connection - www Internet –Published on the WEB. –Uncertain response time. –Global domains. –Mainly for data of public interest.

117 HMIs HTML blablabl abbl HTML blablabl abbl HTML HTML -------l ----- Standard Web Browser (Internet Explorer, Netscape Navigator) W.W.W. WEB Server WEB server Each terminal has a homepage. HTML-pages can contain real-time and PLC/HMI-data HTML-pages are created on PC and downloaded to the terminal

118 HMIs W.W.W. WEB server - remote Monitoring/Manoeuvring and Control

119 HMIs W.W.W. WEB server - remote Monitoring/Manoeuvring and Control

120 HMIs HTML codes User HTML-pages with SSI-code – Function executed when server sees special codes Standard Web Browser (Internet Explorer, Netscape Navigator) W.W.W.

121 HMIs HTML codes User HTML-pages with CGI-Scripts – Standard Web Browser (Internet Explorer, Netscape Navigator) W.W.W.

122 HMIs HTML codes

123 HMIs Standard Web Browser (Internet Explorer, Netscape Navigator) W.W.W. WEB server - remote Monitoring/Manoeuvring and Control JAVA Applet View current screen of terminal Remote control terminal by mouse clicks on PC

124 HMIs W.W.W. WEB server - remote Monitoring/Manoeuvring and Control

125 HMIs Standard FTP client (Included in Internet Explorer, Netscape Navigator) W.W.W. FTP Server FTP server - data transfer Process data transfer – Recipes –log / Trend data –Alarm list Application data transfer –HTML files

126 HMIs GPP/WIN (2001) MM+ (April 2001) W.W.W. Transparent mode Reach PLC through network Requires support from PLC configuration software Tunneling PLC- protocols

127 HMIs Standard POP3 Mail server SMTP Client Outlook Express/Netscape.(POP3) Can redirect mails to f.ex GSM texts W.W.W. You have mail... Mail on alarm Reports through e- mail (textblock) Forwarding E-mails

128 HMIs GOT Product line up F900GOT A900GOT GOT Software

129 HMIs F900GOT Range F940GOT –F940GOT-LWD-E Monochrome –F940GOT-SWD-E –8 colours F930GOT-BWD-E –Monochrome

130 HMIs F900GOT functions Touch screen with IP66F(F940GOT) Security function 1:n Network Transparent Mode Alarm function Recipe function Device Monitor Graphical and Text-Objects F940GOT replaces and contains all functions of FX-50DU-TK(S)-E

131 HMIs Communication connections FX1, FX2, FX2C, FX0, FX0S, FX0N, FX2N,FX2NC Q/A series OMRON SYSMAC C series FUJI N series PC board PLC CPU direct connection CPU direct, PC link CPU direct, RS232C RS232C Connection method PC link Allen-Bradley PLC SLC500 series *Connection to Siemens PLC is also planned.

132 HMIs 146 mm 49 mm 75 mm F930GOT-BWD-E Dimensions Display size: 4.4-inch (280 x 80 dots) Display colour:2-colour (blue/white) Display device: STN Touch switches: 4 x 15 = 60 (50 positions/screen can be set.)

133 HMIs F930GOT benefits Small and Compact high performance GOT Dimensional analysis: –Outer dimensions: 146 x 75mm –Depth: 49mm (45mm recessed into panel) High resolution / Industrys Premiere Resolution –The 240 x 80-dot screen (15 x 5 lines) provides the industrys highest resolution in the small-class display category. Long-Life Backlight / Industrys Longest Lasting Backlight. –A full 50,000 hours of operation with a single Backlight. –This long-life Backlight offers maintenance-free operation.

134 HMIs F930GOT benefits Quick One-Touch Switching –The FX2N and FX2NC series connected (direct CPU connection) –One-touch operations are conducted in 0.16sec with high-speed response. Simple Multiple Connectivity (up to 4 GOTs maximum) –Using direct CPU connections with the MELSEC FX or A Series –A maximum of 4 F930GOTs can be connected to a sequencer.

135 HMIs F930GOT-BWD-E IP66F Rating 146 x 75 x 49mm- classed as the worlds smallest control unit. Easier on the eyes than any comparable screen on the market. Easy-to-read wide-angle LCD. Network expansion a standard feature for up to four units. Sampling mode for measurements and recording.

136 HMIs Networking Hardware Terminal Network with up to 4 stations possible Transparent mode Main control panel remotePremoteQremoteRremoteS 30m15m30m15m RS422 RS232CRS422RS232C PLC

137 HMIs 45° 60° 50° F940GOT Display properties Display properties –320 x 240 Pixel –STN LCD –8 colours or Monochrome –Excellent view from all angles

138 HMIs 5.7in Terminal with less Dimension Water and oil resistent IP66F! Display 5.7In 162 115 23.5 Frame 130 85 22.5 22.5(Frame) 57 F940GOT Dimensions Compact size

139 HMIs Comparison of terminals Category Touch keys Parameters Lamps Memory Freq. Varieties Display mode Trigger Alarm mode FX-50DU-TKSF940GOT Sampling mode History 32 Number 50 I/O 3050 2,000 Dust/Water/Oil 2,000 IP65IP65F 50 128K512K 50256 Same +Oil resist. 8002,000 2001,000 24 x 2.5 Comparison x 1.6 x 1.7 Same x 4 x 5.1 x 5 x 2

140 HMIs Mitsubishis new GOTs A900GOT series A985GOT-TBA-EU –256 colours 800x600 Pixel TFT12 A975GOT-TBA-B-EU –256 colours 640x480 PixelTFT10,4 A970GOT-SBA-B-EU –16 colours 640x480 PixelSTN10,4 A960GOT-EBA-EU –Monochrome 640x400 Pixel EL8,9

141 HMIs Introducing A900GOT High speed screen data transfers and OS transfers. –also store screen data from a GOT in a memory card (PCMCIA) and then edit to a PC List program edit function –minor modification can be made on site –compatible with MELSEC-A Series –command list offers to write, monitor, insert, delete and parameter edit functions

142 HMIs Improved recipe handler Programmable controller D101 D102 D103 D*** Data 1 Data 2 Data 3 Data m m=Max. 8k words n =Max. 256 Recipe data n Recipe data 2 Recipe data 1 Commercial SRAM card or flash PC card

143 HMIs Recipes Mem. card Bus connection and Recipes Fast Bus Connections –use a MELSEC-A/QnA programmable controller for the fastest bus connection. –You can achieve similar performance from three GOTs connected by bus as from a single connected GOT –high speed response via a bus connection for cyclic communication Recipe functions –data can be stored onto memory cards useable by other GOTs

144 HMIs Password input A900GOT Security Security functions –16 security levels

145 HMIs A900GOT Communication speed Bus connection is fastest

146 HMIs A900GOT dimensions 46mm Size (W x H x D) : 297 x 208 x 46 for colour Terminals 268 x 192 x 49 for EL Terminal Extremely slim and compact Slim line terminal using new Bus or RS422 communication modules

147 HMIs Connections A9GT-BUSS –Bus connection A9GT-RS4 –Serial connection PCMCIA card (withQnA series) –Memory cards for programs and recipe

148 HMIs PLC connection FX1, FX2, FX2C, FX0, FX0S, FX0N, FX2N, FX2NC Q/A series OMRON SYSMAC C series Yasukawa series PLC CPU direct communication CPU direct, PC link, A-Bus and Networks. RS232C Connection method PC link Allen-Bradley PLC SLC500 series

149 HMIs GOT Software GT Works, one Software for all GOT (AGOT and FGOT) (SWnD5C-GOTRE-E) FX-DU-SW-WIN-E (Ver.2.30) only for FGOT F900 GOT FX-DU-WIN-SW-ESW4D5C-GOTRE-SW Common DU GOT

150 HMIs GT Works Converter for old projects Documentation function Improved help function Debug function Project manager Templates and tool bar Expanded libraries Simulation Tools

151 HMIs GOT Software Compatibility A900GOT and A870GOT Compatibility FX-50DU-TKS and F940GOT GOT800 screen data Convertor GOT900 screen data FX-50DU-TKSF940GOT FX-DU-WIN-SW

152 HMIs Questions? Human Machine Interfaces