LL/MIT REXIS/OBF T ELECON 12/13/12. Regolith X-ray Imaging Spectrometer – REXIS – LL/MIT REXIS/OBF Telecon 10/11/12 A GENDA (MIT A CTION I TEMS ) Packaging.

Similar presentations


Presentation on theme: "LL/MIT REXIS/OBF T ELECON 12/13/12. Regolith X-ray Imaging Spectrometer – REXIS – LL/MIT REXIS/OBF Telecon 10/11/12 A GENDA (MIT A CTION I TEMS ) Packaging."— Presentation transcript:

1 LL/MIT REXIS/OBF T ELECON 12/13/12

2 Regolith X-ray Imaging Spectrometer – REXIS – LL/MIT REXIS/OBF Telecon 10/11/12 A GENDA (MIT A CTION I TEMS ) Packaging schedule Epoxies to be used in CCD packaging Conformal coating of flexprints Materials information for NASA CCD characterization data 2

3 Regolith X-ray Imaging Spectrometer – REXIS – LL/MIT REXIS/OBF Telecon 10/11/12 P ACKAGING S CHEDULE Still on schedule for 1/21/13 delivery of parts Flexprints, alumina substrates, and circuit components ordered (thanks Keith!) Next is aluminum pieces, transport box after that 3

4 E POXIES FOR CCD P ACKAGING BondCurrent Specification ACIS Specification (from Al) CCD to aluminaAblefilm ECF-550Epotek H37MP Aluminum tee to alumina Crest 3135 A/BAblefilm ECF-550 Flexprint FR-4 to alumina UnspecifiedAblefilm ECF-550 CCD package to aluminum package carrier UnspecifiedCrest 3135 A/B Is the current spec or the ACIS spec correct? Is Crest 3135 RTV or epoxy? Does thermal data exist for Epotek 377? 4

5 Regolith X-ray Imaging Spectrometer – REXIS – LL/MIT REXIS/OBF Telecon 10/11/12 C ONFORMAL C OATING OF F LEXPRINTS Flexprint active circuitry area requires some kind of coating for ESD protection Is solder mask enough? All vias on the board are tented If solder mask is not enough, what is recommended? Where should coating be done? LL or Kavli or by the vendor? 5

6 Regolith X-ray Imaging Spectrometer – REXIS – LL/MIT REXIS/OBF Telecon 10/11/12 M ATERIAL I NFORMATION FOR NASA NASA needs exact specifications on materials we are using in the package Need the following info (see attached spreadsheet) Assembly processes Materials used Standards/specifications for materials used Organics only: Amount used and outgassing data Need to file preliminary spreadsheet by 1/4/13 6

7 Regolith X-ray Imaging Spectrometer – REXIS – LL/MIT REXIS/OBF Telecon 10/11/12 CCD C HARACTERIZATION D ATA What is currently available or can be available soon? Harvard can plug in any available data to their simulations Is anything needed from MIT besides the wish list that was already sent over? I owe Keith a metrology wish list 7