Presentation is loading. Please wait.

Presentation is loading. Please wait.

Network Solutions www.mcscontrols.com. Presentation Overview Network Hardware Types Network Protocols Network Adapters MCS-Magnum Communication MicroMag.

Similar presentations


Presentation on theme: "Network Solutions www.mcscontrols.com. Presentation Overview Network Hardware Types Network Protocols Network Adapters MCS-Magnum Communication MicroMag."— Presentation transcript:

1 Network Solutions www.mcscontrols.com

2 Presentation Overview Network Hardware Types Network Protocols Network Adapters MCS-Magnum Communication MicroMag Communication Example Network Configurations

3 Network Hardware Types Four network hardware types that are used in MCS products: RS485 RS232 Ethernet LonWorks (twisted pair)

4 RS485 Hardware One twisted pair (two conductors) Shielded wire – wrapped foil with drain wire Minimum AWG 20 Max baud rate: 115,000 bit/s Multidrop – point to point Max 30 MCS Controllers wired together Total Network cable length < 4000 (1219m) Can be lengthened with a repeater

5 RS232 Hardware One to one Three conductor 9 or 25 pin connecter Max total cable length < 50 (15m) Can be lengthened with a repeater

6 Ethernet Hardware Star topography 4 twisted pairs (8 conductors) CAT5E Max baud rate: 10 Mbit/s Max cable length < 328 (100m) Can be lengthened with a switch

7 LonWorks Hardware One twisted pair (two conductors) Shielded wire Free topography Minimum AWG 20 Total Network cable length < 3280 (1000m) Can be lengthened with a repeater

8 Network Protocols Network protocols are formatting rules that specify how data is sent and received between devices. Protocols are necessary for devices to interact with each other Protocols MCS controllers support: Bacnet Modbus LonTalk Johnson N2 MCS

9 Network Protocols The MCS Controllers support the following network protocols: Over Ethernet Over RS485 Over LonWorks

10 MCS Network Adaptors MCS uses five different optional network adapters: Hardware Adapters MCS-485-Gateway (RS232 - RS485) MCS-Ethernet (Ethernet - RS232) MCS-USB-RS232 (USB - RS232) Hardware & Protocol Adapters MCS-BMS-Gateway (Bacnet MSTP, LonTalk, Johnson N2) MCS-Bacnet-Router2 (Bacnet IP)

11 MCS-485-Gateway Converts between RS485 and RS232 Used with the MicroMag for a connection to: PC (MCS-Connect) MCS-Touch (MCS-Connect) MCS-Ethernet Can be powered from MCS Controller Only hardware conversion, does not change protocol

12 MCS-Ethernet Converts between Ethernet and RS232 Used with the MicroMag for Ethernet connection to: Internet Comes with 120V wall outlet power adapter Only hardware conversion, does not change protocol

13 MCS-USB-RS232 Converts between USB and RS232 Used for PC (MCS-Connect) communication Powered through USB port Only hardware conversion, does not change protocol

14 MCS-BMS-Gateway Converts Bacnet MSTP (RS485) to: LonTalk (LonWorks) Johnson N2 (RS485) Converts Bacnet IP (Ethernet) to: LonTalk (LonWorks) Johnson N2 (RS485) Bacnet MSTP (RS485) Only supports one MCS-Magnum or MicroMag Can be powered from MCS Controller MCS-Magnum Ethernet Bacnet IP RS485 Bacnet MSTP MCS-BMS-Gateway RS485 Johnson N2 Bacnet MSTP LonWorks LonTalk MicroMag Or RS485 Johnson N2 LonWorks LonTalk Or

15 MCS-Bacnet-Router2 MicroMag RS485 Bacnet MSTP MCS-Bacnet-Router2 Ethernet Bacnet IP Converts Bacnet MSTP (RS485) to Bacnet IP (Ethernet) Supports up to 30 MicroMag Can be powered from MicroMag

16 MCS-Magnum Communication RS485 Port Ethernet Port The MCS-Magnum comes with two hardware communication ports:

17 MCS-Magnum Communication RS485 Bus The MCS Keypad has a built in MCS-485-Gateway and is connected to the RS485 port on the MCS- Magnum These two ports cannot be in use at the same time with different protocols: RS485 port on the MCS-Magnum RS232 port on the MCS-Magnum Keypad RS232 Port

18 MCS-Magnum RS232 The MCS-Magnum can be connected to a PC via MCS-Connect using RS232 located on the MCS- Magnum Keypad The PC may require usb to RS232 adapter, MCS Part # (MCS-USB- RS232) MCS-PC9-MM cable MCS-USB-RS232 The RS485 cannot be used with different protocols when the RS232 is used PC (MCS-Connect)

19 MCS-Magnum RS485 Using the RS485, the MCS-Magnum can be connected to the BMS (Modbus RTU or MCS 485) RS485...... Building Management System The RS232 cannot be used with different protocols when the RS485 is used

20 Wiring Multiple MCS Controllers...... Using the RS485, the network must be wired controller to controller Star configurations not allowed Up to 30 controllers can be wired together CorrectIncorrect

21 Using the Ethernet, the MCS-Magnum can be connected to BMS (Bacnet IP or Modbus IP) MCS-Touch (MCS-Connect) PC (MCS-Connect) Internet access through router (which allows connection via MCS-Connect from anywhere) MCS-Magnum Ethernet Ethernet Or

22 MicroMag Communication Ethernet access can be added with the MCS-Ethernet The MicroMag comes standard with two independent ports: RS232 Port RS485 Port

23 MCS-PC9-MM cable The MicroMag RS232 serial port only supports MCS protocol can be used to connect to: MCS-Touch (MCS-Connect) PC (MCS-Connect) The PC may require usb to RS232 adapter, MCS Part # (MCS-USB-RS232) MicroMag RS232 Or PC (MCS-Connect) MCS-Touch MCS-USB-RS232

24 MicroMag RS485 The MicroMag RS485 port can be used to connect: MCS-Touch (MCS-Connect) BMS (Bacnet MSTP or Modbus RTU or MCS 485) Or Building Management System MCS-Touch...... RS485

25 MicroMag RS485 The MicroMag RS485 port can be used to connect: MCS-Touch (MCS-Connect) BMS (Bacnet MSTP or Modbus RTU or MCS 485) Internet Access using MCS-485-GATEWAY and the MCS-Ethernet MCS-485-GATEWAY MCS-ETHERNET RS232 9pin 25pin Ethernet Internet Router...... RS485

26 Ethernet MCS-Touch Ethernet Example Network #1 Standalone MCS-Magnum MCS-Touch

27 Ethernet Building Management System MCS-Touch Internet Router Example Network #2 Standalone MCS-Magnum MCS-Touch BMS (Johnson N2 or LonTalk or Bacnet MSTP) Internet Access MCS-BMS-Gateway RS485 or LonWorks

28 Ethernet Rooftop/Chiller #1 Building Management System Internet Router Example Network #3 Multiple MCS-Magnum Enclosures Internet Access BMS (Bacnet IP or Modbus IP) Rooftop/Chiller #2

29 RS485 MCS-Touch Building Management System Example Network #4 Standalone MicroMag MCS-Touch BMS (Modbus RTU or Bacnet MS/TP) MCS-PC9-MM cable RS485 MCS-485-Gateway

30 RS485 MCS-Touch Example Network #5 Multiple MicroMags BMS ( Bacnet MSTP or Modbus RTU or MCS 485 ) MCS-Touch Building Management System RS485 RS232

31 Advanced Example Network MCS-Bacnet-Router2 Building Management System MCS-ETHERNET-SWITCH MCS-Touch Multiple MCS-Magnum & Multiple MicroMag MCS-Touch BMS (Bacnet IP)

32 For additional information please visit our website www.mcscontrols.com Or call MCS at 239-694-0089