1 Training Material Multi F / FDx

2 Contents System Introduction ………………….………….…………………….… 1.1 Define……………………………………………………………………………………………….. 1.2 conceptual difference…………………………………………………………………………….. 2. Nomenclature ………………….……………………..……………….… 2.1 ‘Indoor units (Global)….……….….……………………………………………………………… 2.2 Outdoor unit (Global) ………………………………………… 2.3 Indoor units (Europe)……………………………………………………………………………… 2.4 Outdoor unit (Europe)……………………………………………………………………………… 3. Line Up………………….…………………….……….…………….………………………………….. 3.1 Outdoor Unit ……………………………………….….………………………………………….. 3.2 Indoor Units………………………………………… 4. Features & Benefits ……………………………………………………………………… 4.1 Energy Saving ………………………….….……………………………………………………… 4.2 More Powerful…………………………………………………………………………………….. 4.3 Powerful BLDC Compressor……………..….……………………………….………………… 4.4 Step-up Inverter by the PFC & the Sine Wave Control Technology………… 1 2 3 4 4 4 4 4 5 5 6 7 7 7 8 8

3 5. USP…………………………………………………………………………………………
4.5 Wide Range………………………….…………………………………………………………… 4.6 Comfortable…………………………………………….………………………………………… 4.7 BLDC Fan ………………………………………………………………………………………… 5. USP………………………………………………………………………………………… 5.1 Better Performance……………………………………………………………………………… 5.2 Free Joint……………………………………………………………………………………….. 5.3 Compatible Indoors……………………………………………………………………………. 5.4 Changeable Panel (SE, S8)………………………………………………………………….. 5.5 Low Heights Cassette Indoor………………………………………………………………… 5.6 Compact Outdoor……………………………………………………………………………… 5.7 Longer Piping…………………………………………………………………………………... 5.8 Indoor Combination……………………………………………………………………………. 5.9 Small and light weight Outdoors …………………………………………………………….. 5.10 Easy Installation……………………………………………………………………………….. 6. Network Controls……………………………………………………………………….. 7. Application Guidline…………………………………………………………………… 8. References - Petro Pars HQ BLDG…………………………………………………… 9 9 10 11 11 13 14 15 16 17 19 22 24 25 26 27 34

4 Multi-split system 1. System Introduction Non-Inverter Inverter Type
Non Tropical Model Tropical Model Multi Pipe Distributor Box Multi Fixed Joint Multi M Free Joint Multi M/M DX 14~44K 14~30K 48/50K~140K 14~40K 40~45K 35~44K(3Ф) Fixed Free Joint 1/36

5 Single piping with BD box
1. System Introduction Single piping with BD box Up to 9 indoor units *BD unit : Branch Distributor unit Multi piping Up to 5 indoor units • Various combination Total 1,250 types of combination are available with using 13 outdoor units and 56 indoor units • Max. 70% energy saving MPS inverter technology which is using DC inverter compressor and MPS control gives large power saving. • Wide range LG multi provide various indoor units, and outdoor units up to 16.4kW. • Convenient control Various kinds of controllers are available such as PC, Deluxe and Simple Central Controller. • Long and high elevation piping Multi F and Multi FDX system supports a total piping length from 30m to 120m and high elevation from 15m to 30m for more flexibility depending on the installation site condition. • Powerful operation /32

6 1. System Introduction 1.1 Define What is a Multi System ? 2/36
Multi product is one which can connect more than 1 indoor unit. One outdoor unit can be used for 2-3 indoor unit. As seen in the picture 3 Indoor units are connected with a common outdoor unit. 2/36 /32

7 1. System Introduction 1.2 Conceptual difference Single and Multi Systems In single type product we need one outdoor for each indoor unit. Which mean, lots of installation space and number of piping. On the other hand in multi type product we need less installations space piping for many numbers of indoor unit. 3/36 /32

8 1. System Introduction Multi F/FDX System • Wide range
• Various combination Total 1,250 types of combination are available with using 14 outdoor units and 36 indoor units • Wide range LG multi provide various indoor units, and outdoor units up from 4.1kw to 16.4kW. • Convenient control Various kinds of controllers are available such as PC, Deluxe and Simple Central Controller. • Long and high elevation piping Multi F and Multi Fdx system supports a total piping length from 30m to 145m and high elevation from 15m to 30m for more flexibility depending on the installation site condition. • Powerful operation

9 with Less Outdoor Units
1. System Introduction Compared with Stronger Points Multi is Best Solution Single System Same Cooling Power with Less Outdoor Units Less Product Price Less Installation Effort Low Outdoor Noise Space Saving(Outdoor) Ducted System Using Pipe Not Duct Less Installation Effort Less Maintenance Effort Individual Control Less Operation Cost

10 1. System Introduction Constant speed Inverter Compressor Multi piping
Distributor Type Price Low High High Running Cost High Low Low Installation Level Normal Normal Easy 1 phase: 40 ~ 56k 3 phase: 36 ~ 54k Capacity range (Btu/h) 14 ~ 44k 14 ~ 40k

11 2. Nomenclature 2.1 Indoor units (Global) 2.2 Outdoor unit (Global)
4/36

12 2. Nomenclature 2.3 Indoor units (Europe) 2.4 Outdoor unit (Europe)
5/36

13 3. Line- Up 3.1 Outdoor units Multi Multi F Multi F DX 6/36 Old model
New development Max Indoor Units Capacity Range (kBtu/h) Phase Chassis Feature 14 18 21 30 Multi 2 UM (Free joint) 1Φ, 220V 3 UE 4 UE1 Max Indoor Units Capacity Range (kBtu/h) Phase Chassis Feature 14 15 18 21 24 27 30 40 Multi F (Inverter) 2 UE 1Φ, 220V 3 UE 4 UE1 4 UH Max Indoor Units Capacity Range (kBtu/h) Phase Chassis Feature 35 40/42 48 54/56 Here is a complete line up of Multi and Multi Inverter product. The product is available from a wide range of 14 to 30 K in free joint type. Multi F is available from 14K to 40 K and Multi F-Dx is available from 35K to 45 K 7 UH 1Φ, 220V 8 U3 9 Multi F DX (Inverter + DB) 5 UE 7 3Φ, 380~ 414V 8 U3 9 6/36 /32

14 3. Line- Up 3.1 Indoor units Indoor Units 7k 9k 12k 18k 24k
Old model 3.1 Indoor units New development Development plan Indoor Units 7k 9k 12k 18k 24k SRAC S4 S5 ARTCOOL SF Mirror SE S8 4Way CST TR TQ TP Multi F/F DX Indoor Unit TE1 TH 1Way CST TC1 And In Indoor range the lineup of Art cool and Cassette is increased with new S8, TP and TN chassis L.Duct B1 B2 H.Duct BH BUILT IN BP CEILING &FLOOR VE VB 7/36 /32

15 3. Line- Up New New Multi F type
1.A3UW216FA3 between A3UW186FA0 & A4UW246FA3 will be launched newly in 2007. 3Room will be connected and Size of tool is same with FM19AH New New H=655mm W=870 mm D=320 mm H=808mm W=870 mm D=320 mm

16 3. Line- Up New New New Multi F type
1.A4UW276FA3 newly launched in 2008. 2.5 room model added in Line up 3.Capacity of multi piping model increase to 40kbtu. New Volume : 76% New H=1,038mm 4 5 H=808mm D=320 mm D=320 mm W=870 mm W=870 mm New

17 3. Line- Up New New Multi FDX type
1.The volume of A9UW566FA3 decrease 52% in volume 2.Rooms connected to multi Fdx add 1 more.(Max 9 room) New H=808mm D=320 mm W=870 mm New H=1,507mm H=1,380mm D=690mm D=330 mm W=806mm W=950 mm Volume : 52%

18 4. Features and Benefits 4.1 Energy Saving 4.2 More Powerful
An inverter's capacity will fluctuate in order to match the air-conditioning requirements, so an inverter can be more energy efficient than a constant speed compressor. 4.2 More Powerful With a wider operation range for heating and cooling, the inverter is able to operate in even the most extreme outdoor temperatures. An inverter compressor can also operate faster than conventional air conditioners thus allowing the air conditioner to reach the set temperature faster and brings you comfort sooner. 8/36

19 (*PFC :Power Factor Correction)
4. Features and Benefits 4.3 Powerful BLDC Compressor The LG inverter air conditioner comes with a BLDC compressor that uses a strong neodymium magnet. Its compressor thus has improved efficiency compared with AC inverter. 4.4 Step-up Inverter by the PFC & the Sine Wave Control Technology The LG air conditioner is manufactured using the PFC and the sine wave technology. By the PFC control, raising the operating voltage from the existing DC 280V to DC 380V can be done. The sine wave control enables soft operation in a low frequency area, thereby expanding the product's operating range. This also markedly improves the product's energy efficiency. (*PFC :Power Factor Correction) 9/36

20 4. Features and Benefits 4.5 Comfortable 4.7 BLDC Fan
Once the desired temperature is achieved, unlike conventional air conditioners that turn the compressor on and off, LG inverter units adjust and constantly vary the compressor speed to maintain the desired temperature with minimal fluctuation to ensure that your comfort is not compromised 4.7 BLDC Fan BLDC fan motor offers additional energy saving in operating mode. Compared with AC motors, BLDC fan motor can cut energy by 34%at full velocity. AC motor is operating at full velocity only but BLDC Motor can change velocity according to load. Energy efficiency levels at low velocities in particular have been improved by 54%. 10/36

21 Better Performance with higher EER and COP
5. USP 5.1 Better Performance OLD NEW 3.70 3.4 4.40 25% 4.50 14% 9% 23% 3.54 3.21 3.54 3.22 The new multi inverter is much better in performance as compare to previous models. Cooling Efficiency Heating Efficiency Cooling Efficiency Heating Efficiency 24 kBtu/h 30 kBtu/h Better Performance with higher EER and COP (High EER or COP compared to old models at cooling mode as well as heating mode) 11/36 /32

22 Better Performance with higher EER and COP
5. USP 5.1 Better Performance D Company LG 10% 2% 5% 10% 3.4 4.40 4.50 3.90 4.40 4.17 3.54 3.30 We are much better than our competitors in terms of performance. Compare to Daikin the new multi inverter performance is up to 10% higher. Cooling Efficiency Heating Efficiency Cooling Efficiency Heating Efficiency 24 kBtu/h 30 kBtu/h Better Performance with higher EER and COP (High EER or COP against Daikin at cooling mode as well as heating mode) 12/36 /32

23 5. USP 5.2 Free Joint ☞ Multi F/FDx model give you the flexibility to connect any model of indoor unit depending on your choice Also you can see MPS give you free joint that means you can connect any indoor unit depending upon your choice 13/36 /32

24 5. USP 5.3 Compatible Indoors 12 types of indoor units
☞ Twelve different type of indoor unit are compatible with our Multi F/FDx 12 types of indoor units Multi Inverter is compatible with 12 different types of Indoor, Low static duct 14/36 /32

25 5. USP 5.4 Changeable Panel (SE, S8) Multi Indoor - ART COOL Mirror
☞ Compare to old model it is easy to change the panel without disconnecting the wire Old New Only Panel exchange Display Wiring + Panel exchange + + (Display on panel) (Display on body) Display Wiring + Blue (B) In the mirror type, we have new chassis – SE and S8. In this chassis you will find the display on the body rather than on the display panel as was the case in the previous models. By doing this it is easy to change panel, without disconnecting the electrical wiring. Silver (V) Mirror (R) 15/36 /32

26 Before New 5. USP 5.5 Low Heights Cassette Indoor 24 kBtu/h
☞ The new 4 Way Cassette indoor unit are favorable for low ceiling height condition Before New W=950 D=950 H=225 TF Chassis 24 kBtu/h TP Chassis W=840 D=840 H=204 W=570 D=570 W=670 D=670 9 / 12 /18 kBtu/h New 4 way cassette, which is famous with the name of highlander, is compatible with Multi inverter. This new cassette is enhanced version of our cassette models and is very slim. The slim size makes it favorable for low ceiling heights. H=256(TQ) H=269 H=214(TR) TE1 Chassis TR/TQ Chassis Length : mm 16/36 /32

27 5. USP 5.6 Compact Outdoor New Line up Smaller chassis Smaller chassis
21 kBtu/h New Line up UE 27 / 30 kBtu/h Smaller chassis H=1050 H=808 UE1 UE2 D=320 D=320 W=870 W=870 1417 740 540 The outdoors made small and compact for easy installation and easy handling. U3 48 / 54 kBtu/h UY Smaller chassis 1380 900 330 Length : mm 17/36 /32

28 Installation Area Ratio
5. USP 5.6 Compact Outdoor Conventional 48k /54K New 48k /54K Volume Ratio Reduce 42%↓ 940x1,380x330 805x1,407x509 940 805 Installation Area Ratio 47%↓ 509 330 * Comparison of 48/54 kBtu/h Model 18/36

29 LONGER PIPE LENGTH 5. USP 5.7 Longer Piping
☞ The installation is more easy with flexibility of using longer connecting pipes. Capacity Btu/h Max No. of Indoor Piping length (m) Old New 30 k 4 70 75 40 k 5 7 100 115 48 k 8 110 135 56 k 9 120 145 Distributor box Height Main Branch The new multi inverter is much better compared to old one not only performance but also in terms of installation. With longer pipe possible to connect and more number of rooms able to connect the new multi inverter is easy to install in higher buildings LONGER PIPE LENGTH New Multi-Inverter with longer pipe length and more connectivity of room 19/36 /32

30 5. USP Cycle Diagram ① Big size Accumulator
② Cyclone type oil separator Refrigerant Refrigerant+Oil Oil < cyclone type oil separator >

31 5. USP 5.7 Longer Piping (1Ф) (1Ф)
☞ Long & High Elevation Piping : Max Total Piping Length is up to 145m Multi Piping type (1Ф) Distributor type (1Ф) A Indoor Pipe B.D h2 h2 B.D h1 h1 Main Pipe B We can use up to 144m of total pipe length. Piping Length (m) 14/15k 18k 24k 30k 40k Piping Length (m) 40k 48k 54k Total (Main + Indoor) Main Pipe BD – Indoor (Total) (Each) In-Out(h1) In-In(h2) Total(A+B) Max (A) In-Out(h1) In-In(h2) 100 135 145 50 55 55 40 80 90 14 14 14 30 30 30 15 15 15 20/36 /32

32 5. USP 5.7 Longer Piping ☞ Long & High Elevation Piping : Max Total Piping Length is up to 145m Distributor type (3Ф) Indoor Pipe B.D h2 B.D h1 Main Pipe We can use up to 144m of total pipe length. Piping Length (m) 36k 42k 48k 54k Total(Main+Indoor) Main Pipe BD – Indoor(Total) (Each) In-Out(h1) In-In(h2) 100 125 135 145 40 44 55 55 50 70 80 90 20 20 20 20 30 30 30 30 15 15 15 15 21/36 /32

33 163% 5. USP 5.8 Indoor Combination
☞ An example of 30 kBtu/h unit. Number of room connectivity as well a combination ration is improved as compare to previous model 4 Room 5 Room Here you can see an example of 30K unit in which we have added an extra indoor unit and also you can see the service valve is now main service valve type. This service valve is helpful in pump down operation. The indoor room capacity connection is increased from 130% to 153% With Main Service Valve Type OLD NEW 163% 22/36 /32

34 5. USP 5.8 Indoor Combination
☞ We can have a maximum combination ratio of 167% Max Combination Ratio The Indoor room capacity connection can go up to 153% 23/36 /32

35 5. USP 5.9 small and light weight Outdoors
☞ Our new outdoor unit are compact as well as light weight D company Compact Outdoor (30 kBtu/h model) The 30 K outdoor as you can see is made more compact than previous model and also it is lighter in weight than our competitors models. 24/36 /32

36 5. USP 5.10 Easy Installation ☞ Flare type connection makes LG Distributor Box easy to install as compare to our competitors . Our Distributor box is much better than used by our competitor. It is compact and uses flare type joint. You don’t have to go for complex welding as done in our competitor models. 25/36 /32

37 Deluxe Wired Remote Controller Simple Central Controller
6. Network Controls ☞ Applicable in all Multi Inverter units CNU Dry Contact Deluxe Wired Remote Controller PCC LG Air Conditioners Simple Central Controller AC Smart All kind of network control, whether PCC central control or ACP control for controlling number of units from one place or you want to use PDI , Home net all can be use with multi inverter system PDI ACP LON Works HomNet BACNet 26/36 /32

38

39 1. Basic Information / Direction / DC twin compressor
▣ BLDC Motor [ % ] Items AC BLDC Structure BLDC Motor Magnet Efficiency 100 130~125 Twin Rotary Noise 100 90~95 Vibration 100 15~10 ▣ Twin Rotary Wide frequency range - better tower low side - heating capacity improve Rotation Angle(deg) 360 Load Torque Single Rotary Twin Rotary Better control at low & partial load conditions High efficiency Suction (360 ) O Discharge (270 ) O Discharge Valve Vane Cylinder Roller Shaft Low vibration Longer life time of compressor Single Soft start operation “ Reduce the vibration by Twin technology ! “ Compression ( ) O Twin

40 1. Basic Information / Direction / PFC180 control
PFC control increase the voltage operating the compressor form 280V to 380V By using PFC control enlarge the operating range (Low ambient condition) DC280V DC380V

41 1. Basic Information / Direction / PFC180 control
▣ Comparison ▣ Benefit Pulse- wave (120 ) o Sine- wave ( 180 ) o With adoption of sine- wave, PWM * , which smoothes the motor rotation, 1. The operating performance is enhanced. 2. Noise and vibration will be reduced 3. Heating capacity will be raised because of high frequency operating at low ambient 60 120 180 240 300 A相 B相 C相 eA eB eC A+ B+ A- B- C+ C- 60 120 180 240 300 A相 B相 C相 eA eB eC A+ C - B+ A - B - C+ IPM MOTOR IPM MOTOR EMF La La Vdc Ra Vdc Ra EMFa EMFa EMFb EMFc EMFb EMFc Rb Rc Rb Rc Lb Lc Lb Lc * Pulse with Modulation MICOM (8/16 Bits) 3phase voltage Comparison MICOM (32 Bits) Current sensing

42 1. Basic Information / Direction / DC FAN MOTOR
▣ Feature ▣ Benefit Control Power IPM sensor Filter AC Fan Motor Motor Input DC Fan Motor Energy Saving 55-50% 90-95% ▣ Algorithm Load 25℃ 32℃ 39℃ 45℃ 43℃ 37℃ 30℃ 23℃ Step_Fan Step_Fan + 1 Step_Fan + 2 Step_Fan - 1 Step_Fan - 2 -3℃ 4℃ 11℃ 18℃ 16℃ 9℃ 2℃ -5℃ Step_Fan Step_Fan - 1 Step_Fan - 2 Step_Fan + 1 Step_Fan + 2 Along with efficient in the whole range of low speed to high speed, the more improvement is done especially in the low speed operation, compared with the conventional Constant speed AC motor <Cooling mode> <Heating mode>


Download ppt "Training Material Multi F / FDx."

Similar presentations


Ads by Google