1

2 JA-80 Make your premises an Oasis of security EN 0611 d2

3 A solution for your security & comfort......

4 Main differences to the JA-63 1.868MHz radio (up to 2000 meters), no visible antennas, supervision every 9 minutes 2.3V lithium batteries - calculated lifetime 3 years 3.LCD keypad with editable texts 4.RFID proximity card reader built into keypads 5.50 addresses to enroll wireless devices (programmable reactions) 6.Optional enrollment of devices by entering their production code (bar code) 7.2 hard-wired inputs + inputs in keypads, door detectors and PIR detectors 8.Up to 50 users (each can have code, card or both), code management in Comlink 9.2 levels of partial arming or splitting into 2 sections + 1 common section 10.External keypads for access control 11.Totally wire-free outdoor siren 12.Indication of active detectors (open windows or doors) 13.Combined wireless movement and glass-break detector 14.Invisible window-detector 15.Final-door detector function (garage etc.) 16.Annual inspection indication (selectable) 17.Summer / Winter time (selectable) 18.Smart heating control 19.Compatible with CA-1802 and CA-1803 car alarms 20.Identical functions for GSM/GPRS and LAN/PSTN communicators 21.Separate programming of ARC (Automatic Receiving Center) 22.Complies with latest EN and TS standards (grade 2)

5 LEGO architecture

6 JK-81 kit Devices supplied pre-enrolled and pre-programmed Simple installation

7 JK-81 consists of: Control panel with GSM communicator Wireless keypad PIR detector Magnetic detector Indoor siren Key fob Wireless door bell button Proximity card Accessories (batteries etc.)

8 1 5 6 7 Installation in 7 steps 3 4 2

9 Service mode after powering up A: Enrollment of more devices key 1 and connect batteries, exit with # key 1 and connect batteries, exit with # B: Communication quality test key 298 (turns on signal measurement) key 298 (turns on signal measurement) arrow keys scroll devices arrow keys scroll devices device triggering = signal from 1/4 to 4/4 device triggering = signal from 1/4 to 4/4 # returns you to Service mode # returns you to Service mode C: GSM signal strength testC: GSM signal strength test key 922 key 922 return to Service mode by # return to Service mode by # Each signal should be at least 2/4

10 Programming Example: 4 hh mm DD MM YY = clock 201Exit delay 10sec. 81 1 777 775 001 0 = tel. number 9261 = forward SMS

11 299 enrollment of PGX to AC relay X 237 PGX function = on / off

12 Handover to the user

13 SET (arm) UNSET (disarm) Operating a key-fob Both buttons = PANIC

14 Keypad layout Alarm or fault SET A, B and C Power Details Setting (arming) Hot keys A, B & C PGX On / Off Detail reading

15 Let the user feel that (s)he is the master Master card enrollment: 5 1234 card Access card enrollment: 6, Master card, key nn, card Access code programming: 6, Master card, key nn, code To erase access code and card: 6, Master card, key nn, 0000 nn = user number 01 to 50 Each user can have code, card or both John 2375

16 Keypad operation Card / codeUnsetting / Setting ABCComplete setting APartial setting A (if used) BPartial setting B (if used) ?Status details (open windows, PG, faults) PGX on PGX off #Esc Function

17 instructions instructions 1 ABC arming(=ABC button) 2 A arming(=A button) 3 B arming(=B button) 4 Memory reading 5 Master code / card changing 6 Access code / card programming 7 Operating under duress 8 PGX control ( 81/ 80 = on/off or 8 = 2sec. pulse) 9 PGY control ( 91/ 90 = on/off or 9 = 2sec. pulse) 0 Service or Maintenance ( 0 service or master code)

18 2 level partial arming Evening arming Garage…. A C B A Key A A A A A B B B C C C Key B A+B Key ABC A+B+C Night arming Ground floor + garage Complete arming Example: Family house

19 Split system Example: Two families in a house Code or card Bush If both A+B armed, then C also armed A C B AB AB Bush ARMED Blair ARMED Entire house armed incl. Common section Code or card Blair C C

20 Communicator test Both buttons PANIC Panic alarm SMS Result: Function test Knowing the SIM card tel. number

21 Remote access testing Phone keypad authorization: Call and wait for the system to respond (after 5 rings) Enter a valid code (master, user or service) Operate the system - hang up at the end SMS instructions: Code space INSTRUCTION SETArming UNSETDisarming STATUSStatus checking MEMORYLast event memory checking PGX ONTurning PGX on PGX OFFTurning PGX off PGY ONTurning PGY on PGY OFFTurning PGX off AUX ONTurning AUX on AUX OFFTurning AUX off CREDITPrepaid SIM card balance checking

22 Control panel JA-80K Features 1: Back up battery 1.3Ah or 2.6Ah Standby consumption 50 mA 2 wired inputs (01 and 02) - programmable Outputs: EW - external warning (dry contact, max. 1A) IW - internal warning (switches to GND, max. 0.5A) PGX & PGY (switch to GND max. 0.2A) +U power, max. 0.4A Built in transceiver Optional external antenna Up to 50 wireless devices Selectable reactions (Natural or others) Assignment to sections (A, B, C) All devices have natural reaction in section C as factory-default Devices can also be enrolled by keying in their production codes

23 Control panel JA-80K Hard-wired inputs: Maximum of 5 detectors in a loop, Differentiates between triggering and tampering Programmable reaction (Natural = delayed) Enrollment of a wireless device to address 01 or 02 disables the input terminal Max. of 5 detectors in a loop

24 Features 2: Two-level partial setting (A, AB, ABC) Or split system: A, B and C (common section) Devices and codes/cards can have reactions: Off, Natural, Panic, Fire, 24hr., Next delay, Instant, Set, PG control, Set/Unset Up to 5 final-door detectors Intruder alarm confirmation by a 2nd detector Indication of permanently triggered detectors (details by ? key) Annual inspection request indication option Summer / winter time option Memory for the last 255 events Replaceable memory chip Can be operated with up to: 50 user codes (locally or remotely by phone or internet) 50 user cards Option: Confirmation of the card by code Control panel JA-80K

25 The JA-80F keypad LCD (2x 16 characters) 1st line = status or event 2nd line = name of the event source Keypad menu - language selection & chime function Hard-wired input IN (Natural reaction = Delayed) Built in proximity card reader Arrow keys allow you to control PGX (= 81 and 80) A, B & ABC arming hot keys ? Detail reading Keypad turns off after 20sec (if battery powered) 2 x AA Lithium 3V batteries (3 year lifetime - 2 operations/day) JA-80E = hard-wired version

26 Keypad text editing In service mode: Holding ? pressed opens editing Keys: Arrow – selects the text string to be edited 1 and 7 - scroll through characters (A, B, C…..8,9,0) 4 and 5 - move cursor 2 deletes character # exits editing Comlink SW allows more convenient editing - keypad must be connected to the control panel bus

27 The PC-01 proximity card RFID access card (EM UNIQUE 125kHz) Up to 50 cards can be enrolled to the system The card has the same function as an access code For higher security the card can be combined with a code PC-02 is a key tag version

28 The JA-80H outdoor keypad Built in RFID reader Connects to the control panel bus via WJ-80 Provides a doorbell button Illuminated keys IP-65 Standby consumption 45 mA

29 The JA-80N outdoor reader RFID card reader Connects to the control panel bus via WJ-80 IP-65 Standby consumption 40 mA

30 The WJ-80 interface Connects outdoor keypad (reader) to the control panel Built-in door bell transmitter Output to operate an electrical door lock (Z8-12V) Open button input Keypad uses Wiegand protocol 26b DIP switches: 1.System keypad / Outdoor bypass switch 2.PGY can operate the door lock as well (Y/N) 3.Door lock activation time 3 / 6 seconds 4.Exit & entrance beeps (Y/N) Control panel bus Sequence 248 = PGY pulse Authorized phone opening 81 1 777 775 001 79 0

31 The RC-80 key-fob 2 housings provided (2 or 4 buttons) Key lock (4 buttons only) Can also be used with UC, AC, JA-80L an CA-180x Alkaline battery 6V, life time 2 to 3 years Working range up to 100m

32 The RC-88 button DIP switches: Panic (remote control or panic button function) TMP (disable tamper sensors and communication supervision) Can also be used with UC, AC and JA-80L 1x 1/2 AA Lithium 3V battery (3 year life time, max. 20 activations/day)

33 The RC-89 door bell button Works with the JA-80L indoor siren Can be enrolled to the control panel as a portable panic button (by keeping pressed for 3 seconds) Can also be used with AC and UC modules No radio communication supervision 6V alkaline battery Working range up to 200m Mr. Jones

34 The RC-85 remote control module Designed to be installed in a car 3 wires GND A = if connected to +12V transmits signal B = if connected to +12V transmits signal both A + B connected to +12V transmits a panic signal Works with the control panel, UC, AC and JA-80L No battery Flashing full-beam headlights or blowing the horn send signals Can also be used to transmit an alarm from a car alarm

35 The JA-80P detector PIR sensor Hard-wired input IN 15 min test mode after closing the cover DIP switches DEL / INS (natural reaction) NORM / HIGH (immunity level) Covers 120° / 12m Optional lenses (pet, long corridor, vertical curtain) 1 x AA Lithium battery 3V (3 year life time) 5 min sleep time (can be shortened to 1 minute)

36 The JA-80PB detector PIR sensor + glass-break sensor Enrolls to 2 addresses in the system PIR = identical to JA-80P 15 min test mode after cover closing Glass-break DIP switches DEL / INS (natural reaction) PIR / GBS (LED indicator function in test mode) GB detection - up to 9m (can be tested with GBT-212) 2 Lithium 3V batteries: 1 x AA + 1x 1/2 AA

37 The JA-80M detector Magnetic door / window detector Status detector DIP switches: DEL / INS (natural reaction) MG ON / MG OFF (enables/disables internal sensor) 2 input terminals: TMP = tamper input IN = alarm input 1x 1/2 AA Lithium 3V battery (3 year life time for 20 activations/day)

38 The JA-80S detector Fire detector (optical smoke + temperature over 60°) Test button Jumpers: FIRE / INS (natural reaction) SIREN ON / OFF (enables / disables internal siren) 1x AA Lithium 3V battery (3 year life time)

39 The JA-80G detector Combustive gas or fume detector Can be tested with a cigarette lighter Jumpers: 10 / 20% LEL (gas concentration) MEM ON / OFF (memory function) Output relay contact max. 6A Mains powered Prototypes only

40 The JA-85P detector Mini-size PIR detector Can be used in a house or in a car (CA-180x) 15 min test mode after closing the cover DIP switches NORM / HIGH (immunity level) DEL / INS (natural reaction) Supervision ON / OFF Sleep 1 / 5 minutes Semi-sphere lens max. detection distance 5m Communicating range up to 300 meters 1 x AA Lithium 3V battery (3 year life time)

41 The JA-85B detector Mini-size PIR detector Can be used in a house or in a car (CA-1802 or 1803) 15 min test mode after closing the cover DIP switches DEL / INS (natural reaction) Supervision ON / OFF Detection up to 9 meters (can be tested with GBT-212) Communicating range up to 300 meters 1 x AA Lithium 3V battery (3 year life time)

42 The JA-82M detector Invisible window- (door-) detector To be installed in the frame of a window (door) DIP switches: Position closed (A or B) INS / DEL TMP on / off Status / pulse reporting Communicating range up to 300 meters 2 x CR2354 Lithium 3V battery (3 year life time 5 activations/day) A B Prototypes only

43 The JA-80L indoor siren Generates sounds: IW alarm Exit and entrance beeps Door bell - 8 melodies Detector-triggered sounds - 8 melodies LED indicates PGY status Mains powered Tampering reported if disconnected from the power during an alarm Enrolls by plugging in Two volume levels (selectable by keeping the button pressed) Triple click enables/disables arming chirp sounds

44 The JA-80A outdoor siren Totally wire-free !!! Loudness increases gradually Max. duration of the siren sound: 3 min. Flashes 30 min. after the alarm Jumpers: 50 / 25 s. (communication cycle with the control panel) LED ON / OFF (warning flash every minute) Enrolls by connecting its battery Lithium battery BAT-80 (max. life time 3 to 5 years)

45 The JA-80Y communicator Communication via GSM/GPRS GSM gateway function Events reporting by: SMS and phone calls ARC (IP, SMS or CID protocols) ARC programming can be locked Remote access via: Phone (keypad registration or SMS) Internet - www.gsmlink.cz Unanswered ringing from an authorized phone number Remote access possible with a valid code (UC, MC, SC)

46 Combination of LAN and PSTN enables the same features as GSM/GPRS. Most of the JA-80V and JA-80Y functions are identical The JA-80V communicator Communication via LAN & PSTN Events reporting by: SMS and phone calls ARC (IP, CID or DR protocols) ARC programming can be locked Remote access via: Phone (keypad registration or SMS) Internet - www.gsmlink.cz Unanswered ringing from an authorized phone number Remote access possible with a valid code (UC, MC, SC)

47 INTERNET Central monitoring Oasis Telephone network AutomaticReceivingCenter andor Usernotification

48 Remote access Remote access from Internet PC connected to Internet www.GSMLink.cz INTERNET Internet Telephone and or

49 The JA-80X voice communicator Reports alarms with voice messages Up to 4 phone numbers via PSTN 6 voice messages System name Intrusion Fire Tampering Panic Technical alarm Allows remote access via telephone keypad authorization Can be combined with JA-80V or JA-80Y Prototypes only

50 The SP-02 speaker phone For listening in and talking Can be connected to PSTN or to the phone line simulated by JA-80Y Answers calls from authorized numbers Half-duplex communication allows a high sensitivity for listening Push-to-talk feature to call an emergency number 2 x AA alkaline 1.5V battery Prototypes only

51 The UC-82 relay module Powered by 12V DC 2 output relays (X & Y) - max 2A Low bat. output External antenna is optional Can be used with: Control panel Detectors RC-8x transmitters

52 The AC-82 relay module Powered directly from mains 230V, 50Hz 2 output relays (X and Y) - max 5A Can be used with: Control panel Detectors RC-8x transmitters TP-8x thermostats

53 The TP-80 thermostat Enrolls to AC-82 Transmits signals: Temperature below target (normal heating) Below 6°C (anti-freezing) Below 3°C (Freezing alarm - Panic) Above 60°C (Fire alarm) Supervision and battery status Normal heating can be enabled or disabled in the AC-82 receiver by signals from the control panel (PG), remote controls or detectors 1 AA alkaline battery 1.5V, 1 year lifetime

54 The TP-82 thermostat Enrolls to AC-82 Indicates temperature Transmits signals: Temperature below target (normal heating) Below 6°C (anti-freezing) Below 3°C (Freezing alarm - panic) Above 60°C (Fire alarm) Supervision and battery status Normal heating can be enabled or disabled in the AC-82 receiver by signals from the control panel (PG), remote controls or detectors 1 AA alkaline battery 1.5V, 1 year life time TP-83 weekly temperature programming (2007)

55 Simple heating control Thermostat AC-82 Radio Cable Thermostat is enrolled to the AC receiver

56 Heating AC-82 Thermostat Window detectorsControl panel Remote controls Telephone Smart heating system Thermostat is enrolled to the AC receiver and also to the control panel

57 Normal heating control Heating = ON Heating AC-82 Thermostat Window detectorsControl panel Remote controls Telephone Smart heating system

58 Heating AC-82 Thermostat Window detectorsControl panel Remote controls Telephone Smart heating system Operating heating by remote controls ON = normal heating OFF = anti-freezing heating only

59 Heating AC-82 Thermostat Window detectorsControl panel Remote controls Telephone Smart heating system Operating the heating by keypad ON = normal heating OFF = anti freezing heating only

60 Heating AC-82 Thermostat Window detectorsControl panel Remote controls Telephone Smart heating system Operating the heating by a phone ON = normal heating OFF = anti freezing heating only

61 Heating AC-82 Thermostat Window detectorsControl panel Remote controls Telephone Smart heating system Operating the heating by windows CLOSED = normal heating OPEN = anti freezing heating only

62 Heating AC-82 Thermostat Window detectorsControl panel Remote controls Telephone Smart heating system Robbery ALARM !!!!

63 Heating AC-82 Thermostat Window detectorsControl panel Remote controls Telephone Smart heating system Freezing ALARM !!!! (heating is defective)

64 Heating AC-82 Thermostat Window detectorsControl panel Remote controls Telephone Smart heating system Fire ALARM !!!! (temperature above 60 °C )

65 Heating AC-82 Thermostat Window detectorsControl panel Remote controls Telephone Smart heating system Low battery in thermostat

66 Heating AC-82 Thermostat Window detectorsControl panel Remote controls Telephone Smart heating system Communication lost with thermostat

67 Many useful and intuitive features are hidden within the system, disturbing neither the installer nor the end user…. OASiS brings security and comfort

68 The UC-8014 multiple channel receiver Power 230V AC 7 to 28 outputs Extra output for circulation pump Enrolls: thermostats RC controllers window detectors control panel PG outputs Designed for larger heating systems

69 Optional antennas Can be used with: Control panel UC-82 AN-80 AN-81

70 The JA-80T PC cable Connects control panel to PC Provides USB interface Suitable for Comlink 80 and higher JA-80BT (Bluetooth option - 2007)

71 We would appreciate your comments in: http://forum.jablotron.cz Your login will be sent by E-mail

72 Comlink 80 Compatible with JA-6x and JA-80