1 Reference Monitoring @ Q-Cells Intersolar 2011

2 CONTENT 2 1. NETWORK OF REFERENCES UNDER MONITORING 2. EXAMPLES OF PERFORMANCE DATA 3. LIVE LOG-IN TO WEB PORTAL

3 Network of References under Monitoring (1) 3 Why reference monitoring? In reality, STC conditions almost never occur…  Crucial is the performance under real conditions, in different applications and segements!  Monitoring and development of Q-Cells products under real conditions (ex. Anti PID- Technology)

4 Network of References under Monitoring (2) 4 Why reference monitoring? Benefits for you:  Improved performance calculations due to energy yield simulation under real life conditions  Optimisation of system design and installation based on real performance data  Broad reference data base for installation benchmarking

5 Worldwide Reference Network under Monitoring 5  Currently about 68 reference sites under monitoring  Covering nearly all climate conditions, applications, and segments We need you to further build up the worldwide network!

6 CONTENT 6 1. NETWORK OF REFERENCES UNDER MONITORING 2. EXAMPLES OF PERFORMANCE DATA 3. LIVE LOG-IN TO WEB PORTAL

7 * Period: 2010; ** independent certified engineering service (yield certificate) REFERENCE UNDER MONITORING Project: Straßkirchen Location: Bavaria, Germany Power: 51 MWp Orientation: South Inclination: 25° Installation: December 2009 Segment: Utility Application: Field installation Performance Ratio*: 86% Simulated PR**: 81,6%

8 *Period: May 18 – May 31 2011 REFERENCE UNDER MONITORING Project: Potsdam Location: Brandenburg, Germany Power: 8.46 kWp Orientation: South Inclination: 30° Installation: 2010 Segment: Residential Application: Rooftop Performance Ratio*: 86%

9 Überwachte Referenzanlage 9 REFERENCE UNDER MONITORING Project: Delitzsch Location: Saxony, Germany Power: 5,4 kWp Orientation: South Inclination: 40° Installation: March 2010 Segment: Residential Application: Rooftop Performance Ratio*: 86% Special Energy Yield*: 1049 kWh/kWp Simulated PR**: 86,8% Simulated Yield**: 1004 kWh/kWp * Period: March 2010 – February 2011, **PV*SOL Simulation with Application Note

10 REFERENCE UNDER MONITORING Project: Schackenthal Location: Saxony Anhalt, Germany Power: 30,34 kWp Orientation: South-South-East Inclination: 14° Installation: March 2010 Segment: C&I Application: Flatroof Performance Ratio*: 85% Specific Energy Yield*: > 903 kWh/kWp Simulated PR**: 87,5% Simulated Car**: 951 kWh/kWp * Period: March 29th 2010 – March 28th 2011, **PV*SOL Simulation with Application Note

11 REFERENCE UNDER MONITORING Project: Alice Springs Location: Alice Springs, Australa Power: 5,61 kWp Orientation: North Inclination: 20° Segment: Utility (test site) Weblink: http://www.dkasolarcentre.com.au/ Best performance under extreme conditions

12 CONTENT 12 1. NETWORK OF REFERENCES UNDER MONITORING 2. EXAMPLES OF PERFORMANCE DATA 3. LIVE LOG-IN TO WEB PORTAL

13 Live Login to Web Portal 13 Q.PRO example system Q.SMART example system Login-Data:www.q-cells.com/monitoringwww.q-cells.com/monitoring Username: qcells_intersolar_deu qcells_intersolar_eng Password: 2011intersolar Temporary login to web portal for intersolar guests

14 THANK YOU.

15 REFERENCES UNDER MONITORING 15 Irradiance cell (in module plane) Module temperature sensor Ambient temperature sensor Energy counter Data logger Database WAN/GSM Analogue signals Digital Signal (S0) Bus (RS485) Web server / Portal www Inverter interface Monitoring Components

16 References under Monitoring – Indicators 16 SPECIFIC ENERGY YIELD [kWh / kWp]  Energy feed into grid normalized to installed nominal (STC) module power PERFORMANCE RATIO [%]  Irradiance sensor is needed to calculate PR!  Describes, how efficient the incoming irradiance energy is used  Performance Ratio = 100%: The entire system runs with nominal module efficiency

17 Überwachung von Referenzanlagen – Kennzahlen 17  Loss factors: Inverter efficiency, wiring, low light behavior, temperature and shading  Common knowledge, annual PR > 80%: “Good” value

18 REFERENCE UNDER MONITORING Project: Steutz Location: Saxony Anhalt, Germany Power: 22,05 kWp Orientation: South Inclination: 32° IInstallation: March 2010 Segment: C&I Application: Rooftop Performance Ratio*: 87% Special Energy Yield*: 1041 kWh/kWp Simulated PR**: 86% Simulated Yield**: 994 kWh/kWp * Period: March, 18th 2010 – March, 17th 2011, **PV*SOL Simulation with Application Note

19 Überwachte Referenzanlage 19 REFERENCE UNDER MONITORING Project: Solibro Facade Location: Saxony Anhalt, Germany Power: 17 kWp Orientation: South Inclination: 90° Installation: June 2008 Segment: C&I Application: BIPV Performance Ratio*: 84% Special Energy Yield*: 705 kWh/kWp * Period: 2010