Presentation is loading. Please wait.

Presentation is loading. Please wait.

Status of ECAP Simulations for the KM3NeT TDR KM3NeT WP2 meeting Rezo Shanidze Paris, 10-11 December 2008.

Similar presentations


Presentation on theme: "Status of ECAP Simulations for the KM3NeT TDR KM3NeT WP2 meeting Rezo Shanidze Paris, 10-11 December 2008."— Presentation transcript:

1 Status of ECAP Simulations for the KM3NeT TDR KM3NeT WP2 meeting Rezo Shanidze Paris, 10-11 December 2008

2 KM3NeT simulations: from CDR to TDR String design (NIKHEF) Path to TDR : Write up for cable-based design New multi-PMT OM design (from NIKHEF)

3 Multi-PMT OM in cabled design 5. Optical interface 3. PMT base 2. PMT 4. Communication Concentrator 6. Cooling 1. Glass sphere  from  NIKHEF (E. de Wolf, E. Heine ) presentations  at KM3NeT WP 3/4/5 meeting, Paris, 15-16/19/2008 Multi-PMT OM configurations Reference detector vs. Write-up PMTs () () () () CDR (RefDet) 21 0 Write-up 31 19 12

4 V3.4 14/10/2008 Write-up for cabled design

5 KM3NeT detector simulations in ECAP  ANTARES Software: detector physics events PMT hits reconstruction  gendet genhen mupage Simulations in ECAP after CDR km3 reco  New PC-farm in ECAP Erlangen  ANTARES/KM3NeT software installation on PC-farm  mupage for atmospheric-  simulations in KM3NeT PC-farm and ANTARES/KM3NeT related software: Ralf Auer and Claudio Kopper

6 common disk Space ~ 25 TB ECAP PC-farm with Grid Engine queuing system Used by all ECAP groups: ANTARES, KM3NeT, H.E.S.S., Detector development 260 batch nodes 130 interactive nodes ECAP PC-farm for KM3NeT simulations

7 New detector configuration V = A x L DU, A = (n-1) 2 xd 2 CDR: L DU = 595 m, d = 95 m, 1.05 km 3 OMs = 225 x 37 St. = 8325; PMTs =174825 (21x8325) New: L DU = 493 m, D= 105 1.07 km 3 OMs = 225 x 25 St. = 5625; PMTs =174375 (31x5625)  CDR reference detector  new detector:  same instrumented volume ( 1km 3 ), total photocathode area,  number of detection units ( n x n = 15x15=225)  Down-looking PMTS OM with 31x3” PMTs.  CDR 

8 Effective Area  Detector configuration: s25om31d105 Effective area of s25om31d105 configuration, calculated for the different conditions.

9 Detector configuration: s25om31d105 Effective Area vs neutrino angle Next step: Detailed comparison of effective area angular resolution for CDR reference detector and new configuration.

10 Simulation of atmospheric muons: MUPAGE Input: detector surface and physics information: detector geometry, depth Medium: water/ice zenith angle range [0 o,85 o ] max distance of  from the shower axis in a bundle [100m] Range of muon energy [20,10 5 ] GeV Range bundle multiplicity [0,1000] Output: ascii files in table format Equivalent livetime of simulated run  bundle on a can surface Example from M.Spurio (VLVnT08): R, h ~ 300 / 600 m A=1.4 km 2 depth = 2.5 km w.e. Livetime = 1 month E  > 20 GeV, m=[0,100]. 3.6  10 9 bundles 358 files (2h livetime), 600 GB (ascii) CPU: 360 h (2xIntel Xeon Quad Core, 2.33 GHz)

11 MUPAGE simulations @ECAP New simulations with v3.1 ( bug in v2.2, G. Carminati ANTARES PAW meeting, Rome, 25-11-2008)  Current  event sample with  mupage v 3.1 : 10 7 events (  -bundles) at 3 different depth: 2500, 3500, 4800 m with same CAN parameters: R ≈1.2 km, h ≈ 0.8 km, A ≈ 10.3 km 2 Depth (km) Live time ( 10 7 ev sec/h)  -mult CPU / 10 6 CPU/10 5 ( km3 ) file size (MB) ( 10 6 ascii) 2.5 814 / 0.2 1.36 1:29:49 2: 36:31 247 3.5 4320 / 1.2 1.22 1:49:01 2: 42:28 234 4.8 2.4110 4 / 6.7 1.14 2:12:31 2:48:07 226 MUPAGE simulations @ ECAP PC-farm ( 10 7 events) atm-  simulation (MUPAGE ) requires large computing resources and large scale simulations could be performed for the selected TDR detector. Livetime = 1 month for KM3NeT ~ 3 x 10 10  -bundles /2500 m

12 MUPAGE data  Angular distribution of  -bundles at 3 different depth Detector at: -2500 m -3500 m -4800 m Solid angle for Neutrino observation  cos    is slightly larger for  4800 m  mupage simulations:  cos  < -0.087  For 2.5/3.5/4.8 km  cos  <  -0.116/-0.127/ -0.178

13 Expected rate in KM3NeT: few x 10 -3 Hz ( 1  in few minutes ) Expected atm-  -rate ( > 5 hit, Hz) : 2500 / 500 / 100 ( > 10 hit, Hz) : 1750 / 360 / 70 ( > 100 hit, Hz) : 40 / 6 / 1 Expected 40 K hits/10  s : ~ 7000 ( for 4kHz/PMT, 4% of PMTs ) Expected, atm-  and 40 K rates in KM3NeT  atm-  hit rate for MultiPMT det. at 2500 m calculated with MUPAGE and KM3 ( 2.5 km ) Mean number of hits ~ 15.5 [ 2.4 / 3.5 / 4.8 km]

14 Reconstruction of atm-  events Reconstruction of  -events: - necessary to estimate the ate of miss-reconstructed atm-  sample. (keep < 10% for -sample) Reconstruction code in ECAP for KM3NeT: RECO/Aart strategy ( with modifications by S.Kuch ) Example of atm-   reconstruction of  mupage (v2.2) events. No quality cuts !

15 Summary and outlook KM3NeT detector simulation is fully operational and running @ ECAP PC-farm ( thanks to Ralf Auer and Claudio Copper ! ) Atmospheric  simulations (MUPAGE) are included in the KM3NeT TDR studies. ECAP simulations for TDR will be performed for the cabled design option of the KM3NeT detector. Most of the tools needed for the analysis of simulated events are already developed in ECAP ( PhD of Sebastian Kuch). The results for the KM3NeT TDR simulations should be cross- checked with other groups.


Download ppt "Status of ECAP Simulations for the KM3NeT TDR KM3NeT WP2 meeting Rezo Shanidze Paris, 10-11 December 2008."

Similar presentations


Ads by Google