Presentation is loading. Please wait.

Presentation is loading. Please wait.

Aerogel Čerenkov Requirements for the SHMS ( e,e’K + ) Program Hall C User’s Workshop, August 7, 2009. Garth Huber.

Similar presentations


Presentation on theme: "Aerogel Čerenkov Requirements for the SHMS ( e,e’K + ) Program Hall C User’s Workshop, August 7, 2009. Garth Huber."— Presentation transcript:

1 Aerogel Čerenkov Requirements for the SHMS ( e,e’K + ) Program Hall C User’s Workshop, August 7, 2009. Garth Huber

2 Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 2 SHMS (e,e’K + ) Program So far, three SHMS experiments require good K + identification: Experiment Physics Motivation SHMS Momenta (GeV/c) Worst Fore/Bkd Rate Ratio Color Transparency (E12-06-107) vanishing of h-N interaction at high Q.vanishing of h-N interaction at high Q. exclusive π, K production from nuclei.exclusive π, K production from nuclei.5.1-9.61(K):10(p) SIDIS p T (E12-09-017) extract mean k T of u,d,s quarks in proton.extract mean k T of u,d,s quarks in proton. SIDIS π ±, K ± production.SIDIS π ±, K ± production.1.5-5.0 K Factorization (E12-09-011) study of soft-hard factorization in exclusive K + production.study of soft-hard factorization in exclusive K + production. L/T separations vs. Q 2, t.L/T separations vs. Q 2, t.2.6-7.11(K):3(p)

3 Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 3 p(e,e’K + ) Missing Mass Resolution Simulation at Q 2 =2.0 GeV 2, W=3.0 and high ε. Example from K + Factorization Proposal.Example from K + Factorization Proposal. SHMS+HMS missing mass resolution (~30 MeV) clearly sufficient to separate Λ and Σ° final statesSHMS+HMS missing mass resolution (~30 MeV) clearly sufficient to separate Λ and Σ° final states Good π + /K + (p/K + ) separation using heavy gas (aerogel) Cerenkov is absolutely required.Good π + /K + (p/K + ) separation using heavy gas (aerogel) Cerenkov is absolutely required. Λ Σ° p(e,e’K+)Λ(Σ°) SHMS+HMS

4 Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 4 non-TOF Particle ID @ 1-11 GeV/c Heavy Gas Č erenkov Aerogel Č erenkov TOF * Diagram from SHMS CDR Note: n=1.02,1.015 leads to poor K/p separation at higher momenta.

5 Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 5 Aerogel Indices of Refraction (n) K/p separation progressively more difficult at higher momenta.K/p separation progressively more difficult at higher momenta. To maintain reliable K/p separation over a wide momentum range aerogels with variety of n are required.To maintain reliable K/p separation over a wide momentum range aerogels with variety of n are required. p SHMS (GeV/c) n (10cm) K N pe p N pe 2.5-3.01.03013-46<0.5 3.1-3.71.02012-31<0.5 3.8-4.31.01513-24<0.5 4.4-5.11.0105.5-<0.5 5.2-6.21.00755.5-13<1 6.4-7.31.00556-9<1 Calculation assumes good PMT spectral response, 75% light collection efficiency.

6 Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 6 S1 Hodoscope Space Reserved for 1-2 Aerogel Č erenkovs SHMS Detector Stack Drift Chambers C 4 F 8 O Č erenkov S2 Hodoscope Ar/Ne Č erenkov Calorimeter

7 Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 7 Aerogel Č erenkov Design Considerations Requirements: Easy and fast exchange of Aerogel tray is essential.Easy and fast exchange of Aerogel tray is essential. Although only one Aerogel Čerenkov is required at any P SHMS,Although only one Aerogel Čerenkov is required at any P SHMS, two detectors would reduce accesses to swap Aerogel when changing momentum. Detector must be slender.Detector must be slender. HMS Aerogel is 25cm thick.HMS Aerogel is 25cm thick. Minimum active area: 110x130cm 2.Minimum active area: 110x130cm 2. Compare to 70x120cm 2 for HMS.Compare to 70x120cm 2 for HMS. Division into optically isolated segments could enhance high rate capability.Division into optically isolated segments could enhance high rate capability. HMS Aerogel Č erenkov ISO View

8 Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 8 HMS Aerogel Č erenkov Performance Baseline of 0.6 photoelectrons for sub-threshold particles.Baseline of 0.6 photoelectrons for sub-threshold particles. π detection efficiency in n=1.030 aerogel >99% with N pe >4 cut applied.π detection efficiency in n=1.030 aerogel >99% with N pe >4 cut applied. Variation in total light detected varies by up to 20% across focal plane due to varying path of light through aerogel to PMT and other factors.Variation in total light detected varies by up to 20% across focal plane due to varying path of light through aerogel to PMT and other factors. R. Asaturyan, et al., NIM A548 (2005) 364.

9 Dr. Garth Huber, Dept. of Physics, Univ. of Regina, Regina, SK S4S0A2, Canada. 9 Summary Currently, there are three approved SHMS experiments requiring K + identification.Currently, there are three approved SHMS experiments requiring K + identification. –Anticipate more experiments with this requirement in future. Threshold Aerogel Čerenkov detector is simplest and most economical way to satisfy K/p separation requirement.Threshold Aerogel Čerenkov detector is simplest and most economical way to satisfy K/p separation requirement. – ~6 sets of aerogel with different n would enable excellent K/p separation over a wide momentum range. –Also helpful to supplement π ± identification below 3.4 GeV/c. Design considerations: Design considerations: – Helpful if aerogel tray can be changed relatively easily. – Very attractive to have 2 Aerogel Čerenkovs in detector stack. Need to watch space requirements very carefully!Need to watch space requirements very carefully! – SHMS beam envelope more square than HMS. Need to avoid efficiency drop in center of detector.Need to avoid efficiency drop in center of detector.


Download ppt "Aerogel Čerenkov Requirements for the SHMS ( e,e’K + ) Program Hall C User’s Workshop, August 7, 2009. Garth Huber."

Similar presentations


Ads by Google