Presentation is loading. Please wait.

Presentation is loading. Please wait.

MINISTÈRE DE LA DÉFENSE MATERIALS IN HIDDEN AREAS RADIANT PANEL TEST RESULTS.

Similar presentations


Presentation on theme: "MINISTÈRE DE LA DÉFENSE MATERIALS IN HIDDEN AREAS RADIANT PANEL TEST RESULTS."— Presentation transcript:

1 MINISTÈRE DE LA DÉFENSE MATERIALS IN HIDDEN AREAS RADIANT PANEL TEST RESULTS

2 october 9-10, 2002 CEAT/SEI MINISTÈRE DE LA DÉFENSE MATERIALS IN HIDDEN AREAS 1-MATERIALS CURRENTLY USED IN COCKPIT AND CABIN TWO THERMOPLASTICS LAMINATED PANEL GLASS/PHENOLIC-2PLIES SANDWICH PANEL NIDA NOMEX+ 4 PLIES GLASS/PHENOLIC

3 october 9-10, 2002 CEAT/SEI MINISTÈRE DE LA DÉFENSE MATERIALS IN HIDDEN AREAS 2- Combination of an insulation blanket film pvf + 30 wires bundled with attachment clamps made of polyamide the attachment clamps meet the requirements of the vertical bunsen burner test 12 seconds

4 october 9-10, 2002 CEAT/SEI MINISTÈRE DE LA DÉFENSE MATERIALS IN HIDDEN AREAS RADIANT PANEL STANDARD TEST METHOD SIZE OF THE SPECIMEN : 15x 12 cm

5 october 9-10, 2002 CEAT/SEI MINISTÈRE DE LA DÉFENSE MATERIALS IN HIDDEN AREAS IGNITION TIME : 60 seconds SIZE OF THE SPECIMEN: 50 X 17, 5 cm

6 october 9-10, 2002 CEAT/SEI MINISTÈRE DE LA DÉFENSE MATERIALS IN HIDDEN AREAS TESTS ON WIRES + ATTACHMENT CLAMPS + INSULATION BLANKETS FIRST RESULTS A LOT OF DISPERSION - 14 or 30 wires bundled located on blanket with 2, 3 or 4 clamps separated at 2 to 5 cm - clamps melted after removing the pilot burner - The flame remains or not afterwards.

7 october 9-10, 2002 CEAT/SEI MINISTÈRE DE LA DÉFENSE MATERIALS IN HIDDEN AREAS In some hidden parts the space out between two attachment clamps is less than 1,5 cm scenario : 30 wires bundled + 5 clamps separated every 1 cm and located on the insulation blanket

8 october 9-10, 2002 CEAT/SEI MINISTÈRE DE LA DÉFENSE MATERIALS IN HIDDEN AREAS BEFORE THE TESTAFTER THE TEST

9 october 9-10, 2002 CEAT/SEI MINISTÈRE DE LA DÉFENSE MATERIALS IN HIDDEN AREAS During the test, the burner removed

10 october 9-10, 2002 CEAT/SEI MINISTÈRE DE LA DÉFENSE MATERIALS IN HIDDEN AREAS 3 tests carried out : film melted cable ties melted and flames remained after removing the pilot burner test 1 after flame time : 6 minutes 53 secondes test 2 after flame time : 4 minutes 32 secondes test 3 after flame time : 6 minutes 35 secondes


Download ppt "MINISTÈRE DE LA DÉFENSE MATERIALS IN HIDDEN AREAS RADIANT PANEL TEST RESULTS."

Similar presentations


Ads by Google