Presentation is loading. Please wait.

Presentation is loading. Please wait.

Brett Fadem of Muhlenberg College for the PHENIX Collaboration.

Similar presentations


Presentation on theme: "Brett Fadem of Muhlenberg College for the PHENIX Collaboration."— Presentation transcript:

1 Brett Fadem of Muhlenberg College for the PHENIX Collaboration

2 Overview The goal Transverse energy for a new kinematic range Definition Motivation The main tool The Muon Piston Calorimeter (MPC) Kinematic coverage Performance Plans for the Future

3 Definition of Transverse Energy θ i is the polar angle E i is the kinetic energy for nucleons Total energy for all other particles

4 Motivations A new kinematic region for E T at RHIC A necessary first step toward fluctuations Search for critical point See, for example, M. Stephanov, K. Rajagopal, E. Shuryak, Phys.Rev.Lett. 81 (1998) 4816-4819

5 ~220 cm from vertex Location of MPC stations Good coverage!

6 North Location South Location Pre-installation During installation

7 North Station 220 PbWO 4 Crystals 3.1 < |η|< 3.8 South Station 196 PbWO 4 Crystals 3.1 < |η|< 3.7

8 PbWO 4 Crystals and Avalanche Photodiodes Density8.28 g/cm 3 Size2.2 x 2.2 x 18 cm 3 Length20 X 0, 0.92 int. lengths Weight721.3 g Moliere radius2.0 cm Radiation Length0.89 cm Interaction Length22.4 cm Light Yield~10 p.e./MeV @ 20 °C Temp. Coefficient-2% / °C Radiation Hardness1000 Gy ~10 yr cont. at PHENIX Main Emission Lines420-440, 500 nm Refractive Index2.16 PreAmp APD Holder PbWO 4 Crystal

9 Avalanche Photodiodes Hamamatsu S8864-55 5 × 5 mm square, large area Gain ~50

10 New PHENIX Calorimeter Acceptance PbGl PbGl / PbSc FC MPC ZDC FCAL ZDC

11 PHENIX Au+Au √s NN = 130 GeV Phys. Rev. Lett. Volume 87, Number 5, 30 July, 2001 |η| ≤ 0.38

12 STAR Au+Au, √S NN = 200 GeV arXiv:nucl-ex/0407003v1 2 Jul 2004 Phys. Rev. C70 (2004) 054906 0 < η ≤ 1

13 Au+Au, √S NN = 200 GeV, Detector Performance

14 MPC π 0 from Run 6 p+p data Background subtracted All Pairs Mixed Events Photon Pair Cuts Pair Energy > 8 GeV Asymmetry |E 1 -E 2 |/|E 1 +E 2 | < 0.6 Noisy towers Width ~ 20 MeV Shower Reconstruction Using Shower Shape Fits Reconstruction of π 0 in Au+Au data is plausible for peripheral Collisions

15 MPC Minimum Ionizing Peak MIP Peak Energy Scale Set by MIP Confirmed with π 0, η peaks Peak corresponds to ~ 240 MeV

16 Fluctuations in Forward Direction? Event by Event Fluctuations in mean P T and mean E T in √s NN = 130 GeV Au+Au Collisions K. Adcox et al., PHENIX Collaboration, Phys.Rev. C66 (2002) 024901 No significant non-random fluctuations observed at central rapidities Maybe in the forward direction we’ll get a different answer

17 Plans for the Future RHIC 2006/2007 Run 7 Au+Au at 200 GeV/c 2.9 Billion minimum bias events are available Continuing work on π 0 peak, and calibrations Using all towers Tower by tower Systematic study of hadronic contribution

18 Acknowledgements Joshua Adams, Undergraduate at Muhlenberg College Mickey Chiu, BNL Physics National Science Foundation


Download ppt "Brett Fadem of Muhlenberg College for the PHENIX Collaboration."

Similar presentations


Ads by Google