Page 1 www.photek.co.uk 1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications Panos.

Similar presentations


Presentation on theme: "Page 1 www.photek.co.uk 1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications Panos."— Presentation transcript:

1 page 1 www.photek.co.uk 1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications Panos

2 www.photek.co.uk 2 Summary Introduction to Photek Photek MCP – PMTs The TORCH PMT Lifetime Gain Uniformity High granularity multi-anode Readout Square tube development

3 www.photek.co.uk 3 Company Profile Specialist manufacturers of photon detectors and camera systems. Photek manufacture Image Intensifiers, PMTs, Streak Tubes, open faced detectors and a range of associated electronics and camera systems Located in St Leonards-on-Sea – South East England Established September 1991

4 www.photek.co.uk 4 Company Profile 50 Employees –11 sales/administrative –7 R&D –32 production/test > 6 employees educated to PHD level Further 10 employees educated to degree level

5 www.photek.co.uk 5 Photek MCP-PMTs Photek currently manufacture the fastest PMTs in the world in “analogue mode”: –Whole pulse is captured by an oscilloscope or digitiser –Applications often “single-shot, high intensity”, e.g. Fusion Research –We have several detectors on the diagnostics at the National Ignition Facility

6 www.photek.co.uk 6 Photek MCP-PMTs Rise Time (ps) MCPs Detector Active Diameter 10 mm25 mm40 mm Min.Typ.Max.Min.Typ.Max.Min.Typ.Max. 05060801006080100 1606570115100150200 2758595*180230280 3*300400500350 FWHM (ps) MCPs Detector Active Diameter 10 mm25 mm40 mm Min.Typ.Max.Min.Typ.Max.Min.Typ.Max. 080100150200100150200 1100110120170300450600 2130150170*6008501100 3*80010001200

7 www.photek.co.uk 7 Photek MCP-PMTs MCP-PMTs are also the leading detector for time-resolved photon counting Jitter in photon arrival measurements ~ 30 ps FWHM –Significantly better for multi-photon events Excellent fit for Cherenkov-based particle detection Drawbacks: –Detector Lifetime –Most models are round, single anode and not close-packing

8 www.photek.co.uk 8 The TORCH PMT In November 2012 Photek started the 3-year development of the TORCH (Timing Of internally Reflected CHerenkov photons) PMT A collaboration with CERN and the Universities of Oxford and Bristol for the LHCb upgrade Technical aims: –A lifetime of 5 C/cm 2 of accumulated anode charge or better –A multi-anode readout of 8 x 128 pixels –Close packing on two apposing sides with a fill factor of 88% or better 53 mm working width within a 60 mm envelope

9 www.photek.co.uk 9 The TORCH PMT Three main aims: 1.Lifetime 2.High granularity multi-anode 3.Square

10 www.photek.co.uk 10 1. MCP-PMT Lifetime Standard MCP detectors suffer from sensitivity loss after prolonged exposure: –An MCP has a very large surface area –Prolonged electron bombardment of this surface releases material that is ionised –These ions are drawn back to the photocathode and reduce sensitivity Previous solutions have involved barrier films to prevent the ions reaching the photocathode –Limited success –Lowers MCP efficiency and overall sensitivity

11 www.photek.co.uk 11 1. MCP-PMT Lifetime Recent technology of ALD (Atomic Layer Deposition) coating on MCP has significantly reduced out-gassing Two PMT samples produced in 2011: Double-MCP 10 mm diameter working area –One with coated MCPs, One control with standard MCPs Independently verified by Photek and others: Britting et al (PhotoDet 2012), Conneely et al (VCI 2013)

12 www.photek.co.uk 12 1. MCP-PMT Lifetime ALD coating results in no detectable sensitivity loss after > 5 C/cm 2 Some gain reduction 6 test devices produced, 2 successfully life tested at Photek, 1 currently being tested at CERN

13 www.photek.co.uk 13 1. MCP-PMT Lifetime 1 st year objective: produce 5 long-life MCP-PMTs –1 st build cycle produced 6 double-MCP devices plus 1 control –ALD also gives major gain enhancement –A 2 nd build cycle will attempt to produce a photon counting device with 1 MCP

14 www.photek.co.uk 14 1. MCP-PMT Lifetime In other respects, coated MCPs behave as normal Jitter measurement made with 40 ps laser source

15 www.photek.co.uk 15 1. MCP-PMT Gain Uniformity At the RICH conference in Japan 2013 Albert Lehmann observed substantial gain non-uniformity with ALD coated MCPs We tried to repeat this observation but could not detect anything significant This region is due to an artefact in our scanning software This region shows the gain suppression after the life test

16 www.photek.co.uk 16 2. High granularity multi-anode Traditional multi-anode manufacturing uses multiple pins brazed through a solid ceramic Prone to leaking, also unrealistic for a 128 x 8 array! Our aim is to use multilayer ceramic with filled vias Much smaller pad size allows for finer pitch The pads on this design are 0.75 mm wide on a 0.88 mm pitch Vacuum side Air side

17 www.photek.co.uk 17 2. High granularity multi-anode Using a method of charge sharing between pads, we can reduce the channel count and the required granularity of the multi-anode structure The plot shows the simulated position resolution of a parallel readout, charge sharing detector (using the NINO and HPTDC as readout electronics) in the fine direction of the required 8 × 64 pad layout but aiming for 8 × 128 resolution The position resolution strongly depends on the NINO threshold and detector gain, with this plot showing a gain of 1 × 10 6 or greater being required to achieve the desired resolution

18 www.photek.co.uk 18 2. High granularity multi-anode Contact made to anodes by Anisotropic Conductive Film (ACF) – ACF are filled with conductive particles which provides electrical interconnection between pads through the film thickness (z- direction) – The conductive particles are distributed far apart thus not electrically conductive in the plane direction (x & y) of the film –PCB could contain front-end electronics and/or connectors Detector ACF PCB x y z ACF is insulating in x and y but conducting in z

19 www.photek.co.uk 19 2. High granularity multi-anode - readout NINO ASIC 32 channel differential amplifier /discriminator developed at CERN 10 ps RMS jitter on the leading edge >>10 MHz maximum rate The time-over-threshold technique uses the discriminator output pulse width to determine the event charge High Performance Time-to-Digital Convertor (HPTDC) A programmable TDC developed for ALICE time-of-flight RPCs at the LHC Two modes of 100 ps LSB resolution with 32 channels, or 24.4 ps LSB resolution with 8 channels Default maximum rate is 2.5 MHz per channel, can be increased beyond 10 MHz using higher logic clock

20 www.photek.co.uk 20 3. Square Tube Development Square tube manufacturing at Photek Currently developing methods of –Square body brazing –Square MCP locating –Square photocathode sealing –Square anode sealing Current status: –Producing leak-tight square test cells

21 www.photek.co.uk 21 Summary TORCH PMT in development at Photek 3 year development aims to finish in November 2015 1 st year task complete: To produce long-life demonstrators 2 nd year task on-going: To produce high-granularity multi-anode demonstrator Final year task: Fully functioning detector

22 www.photek.co.uk 22 Thank you for listening The support of the European Research Council is gratefully acknowledged in the funding of the PMT development through an Advanced Grant under the Seventh Framework Programme (FP7) (ERC-2011-AdG 299175- TORCH).