Presentation is loading. Please wait.

Presentation is loading. Please wait.

CNI polarizations in Run09: Summary A.Bazilevsky For the RHIC CNI Group March 26, 2010 RSC meeting.

Similar presentations


Presentation on theme: "CNI polarizations in Run09: Summary A.Bazilevsky For the RHIC CNI Group March 26, 2010 RSC meeting."— Presentation transcript:

1 CNI polarizations in Run09: Summary A.Bazilevsky For the RHIC CNI Group March 26, 2010 RSC meeting

2 Run9 results Released on Feb 4, 2010: http://www4.rcf.bnl.gov/~cnipol/pubdocs/Run09Offline/ Gives: Fill#, Polarization, Stat. error, Syst. Error Global syst. errors (to all fills) Short analysis description: NOTE_2009_Polarizations_RHIC.txt Detailed analysis description: pC_2009.pdf

3 Briefly Hjet: Absolute beam polarization Continuously running in a fill Absolute stat. uncertainty in a fill: 0.04-0.07 ~50% fills at  s=500 GeV and ~80% fills at  s=200 GeV Statistics accumulated in many fills used to normalize pC pC (two polarimeters in a ring): 3-4 measurements in a fill (every 2-3 hours) in target scan mode Pol. profile Many more parameters: pol. decay in a fill, pol. vector in trans. plane, beam emittance etc. Polarization for experiments (in collisions), after normalization to Hjet and correction for pol. profile

4 Run9 results

5 Systematic Errors

6 Syst. Errors: HJet Jet normalization, stat: 2.5% for 250 GeV and 1.0% for 100 GeV That’s what existing data gave us Jet normalization, syst (dilution): 2% That’s what we’ve been using since Run4 (molecular contribution) Jet normalization, syst (backgr): 2-3% From the measurements of backgr. asymmetries Run8: 1.3-2.4%; Run6: 1.3-1.9%

7 pC: Time dependence in a fill Time, hr 0.68 0.56 0.64 0.49 0.60 0.53 0.62 0.44 0.64 0.52 0.60 0.40 0.70 0.57 0.62 0.54 Pol. decay!

8 pC: average over a fill T p decay – from pC T L decay = 5 hr   Comparison of with T L decay = 5 hr and  (T L decay =  is equivalent to a weighted average) Only few fills showed syst. problems  assign additional syst. error for these fills

9 pC in 2009: issues and strategy Rate related systematics Particularly at  s=500 GeV Failed to find a way to correct it (rate is defined by prompts which are already cut off by DAQ) Strategy: Two polarimeters in a ring are averaged Fill-by-fill systematic uncertainties evaluated from the comparison between two polarimeters and between pC and HJet

10 Fill dependence (pC vs HJet) No systematic effect seen on the HJet stat. error level 250 GeV

11 Fill dependence (pC vs HJet) No systematic effect seen on the HJet stat. error level 100 GeV

12 Fill dependence (Pol1 vs Pol2) 250 GeV RMS of the variation  12% fill-by-fill syst. uncertainty Not yet normalized to HJet

13 Fill dependence (Pol1 vs Pol2) 100 GeV RMS of the variation  6% fill-by-fill syst. uncertainty Not yet normalized to HJet

14 Pol. Profile (all) 100 GeV250 GeV ~0.08~0.40

15 Pol. Profile (good) 100 GeV250 GeV ~0.08~0.40

16 Pol. Profile: summary 250GeV: =0.36  0.14; with fill-by-fill variation  0.36 100GeV: =0.08  0.04; with fill-by-fill variation  0.08 =0.36  0.14  (15  5)% correction from Hjet to experiments =0.08  0.04  (4  2)% correction from Hjet to experiments

17 Summary Global systematic uncertainties: Blue,  s=500 GeV: 8.3% Yell,  s=500 GeV: 12.1% Blue,  s=200 GeV: 4.7% Yell,  s=200 GeV: 4.7% http://www4.rcf.bnl.gov/~cnipol/pubdocs/Run09Offline/ Run5: 5.9% and 6.2% Run6: 4.7% and 4.8% Run8: 4.2% and 7.2%

18 Path Forward

19 Backup

20 Sookhyun: Background raw asymmetries Target Asymmetry (raw) Beam Asymmetry (raw) Possible Effect on Polarization Blue single 250GeV 0.001477+- 0.004277 0.003105+- 0.004277 <2.1% Blue double 250GeV -0.001656+- 0.001303 0.003274+- 0.001303 <2.2% Blue 100GeV-0.000704+- 0.000734 0.002949+- 0.000734 <1.1% Yellow 250GeV-0.000969+- 0.001999 -0.006447+- 0.001999 <4.0% Yellow 100GeV-0.000552+- 0.000722 -0.002235+- 0.000722 <0.9% From Mean  Sigma

21 pC: pol. Decay in a fill  s=500 GeV 1/T decay Affected by rates! = 10-100 hours ( =100 hr  1%/hr) Run6: ~150 hours Run8: ~400 hours ~100 hours In a fill: fit to exp(-t/T decay )

22 pC: pol. Decay in a fill  s=200 GeV 1/T decay = 50-200 hours ( =100 hr  1%/hr) Run6: ~150 hours Run8: ~400 hours ~100 hours Affected by rates! In a fill: fit to exp(-t/T decay )

23 pC: Time dependence in a fill  s=500 GeV

24 Time dependence (pC vs HJet), vs period  s=500 GeV

25 Time dependence (pC vs HJet), vs period  s=200 GeV

26 Pol1 vs Pol2  s=200 GeV Yell Blue  s=500 GeV

27 Pol. Profile: rate dependence  s=200 GeV  s=500 GeV

28 Horizontal component  ~5-10 0 |  |<5 0  s=200 GeV  s=500 GeV  ~5 0 |  |<5 0

29 pC: Intensity Profile Bad profile: Non-gaussian High rate Rate problem? Good profile: Perfect gaussian Low rate Bad profile: Non-gaussian Low rate Target positionig problem?

30 pC: Polarization Profile pC Scan C target over the beam cross: Target Position Intensity Polarization II PP 2. Obtain R directly from the P(I) fit:   P I Precise target positioning is NOT necessary 1. Directly measure  I and  P : R=0.29  0.07

31 Normalization for pC (Hjet/pC) Initial normalization from Run4 (  s=200 GeV)

32 ANAN pC pp


Download ppt "CNI polarizations in Run09: Summary A.Bazilevsky For the RHIC CNI Group March 26, 2010 RSC meeting."

Similar presentations


Ads by Google