Workshop on Safety Tests for Electrical Products Cairo, Egypt 3 – 4 December 2014 Performance tests for electrical lamps, LED lamps and electrical lanterns.

Similar presentations


Presentation on theme: "Workshop on Safety Tests for Electrical Products Cairo, Egypt 3 – 4 December 2014 Performance tests for electrical lamps, LED lamps and electrical lanterns."— Presentation transcript:

1 Workshop on Safety Tests for Electrical Products Cairo, Egypt 3 – 4 December 2014
Performance tests for electrical lamps, LED lamps and electrical lanterns Dean Zekic Higher market inspector Croatian Ministry of economy

2 covers all aspects of safety (electrical, thermal and mechanical).
IEC –luminaires incorporating electric light sources for operation from supply voltages up to V classification, marking, mechanical construction and electrical construction. covers all aspects of safety (electrical, thermal and mechanical). TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

3 Standards IEC Particular requirements for particular type of luminaire: Ie.: Part 2-1 Fixed general purpose luminaires TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

4 Classification Protection against electrical shock Class I luminaire:
basic insulation + protective earthing Class II luminaire: basic + supplementary insulation or reinforced insulation Class III luminaire: SELV (safety extra-low voltage) TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

5 Classification According to degree of protection against ingress of dust, solid objects and moisture – ‘’IP number’’ system classification against contact with or approach to live parts and moving parts IP3X Protected against solid objects greater than 2,5 mm → IP6X Dust-tight Protection of the equipment inside the enclosure against harmful ingress of water Ordinary IP20 → Pressure-watertight (submersible) IPX8 m (followed by an indication of the maximum depth TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

6 Classification No symbol
material of supporting surface for which the luminaire is designed direct mounting on normally flammable surfaces Luminaires not suitable for direct mounting on normally flammable surfaces Classification according to the circumstances of use Luminaires for normal use Luminaires for rough service No symbol TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

7 Marking Marking on products - distinctly and durably marked on the luminaire Graphical symbols ≥5 mm, letters and numbers ≥ 2mm Test of marking Informations required for certain actions must be visible during that actions replacing lamps or other replaceable components during installation after installation

8 Marking Mark of orign - trade mark, the manufacturer's identification
Maker's model number or type reference Rated voltage in Volts (V) Rated wattage in Wats (W) The rated maximum ambient temperature, if other than 25 °C Symbols of protection against electrical shock IP number mark …. TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

9 Marking aditional information
Additional information details which are necessary for insuring safety during instalation, use, and maintenance Wiring diagram Special conditions …. Written instructions must be on acceptable language TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

10 Construction - Lampholder
Positioning test TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

11 Construction - Lampholder
Bending test TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

12 Construction - Lampholder
Torque test TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

13 Construction – Terminal block
Space Luminaire with connecting leads requires a terminal block to connect to fixed wiring Adequate space for terminal block TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

14 Construction – Reliable terminals
8 mm conductor live conductor earth conductor TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

15 Construction – Reliable terminals
External cable & Internal wiring Retained by cord anchorage Clamped by spring terminal TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

16 Construction – Reliable terminals
Internal wiring - Anchored to a tag before soldering - Twisted in a reliable manner - Fasten by sleeve, tape - Inserted into a hole of PCB, bend and soldered TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

17 Construction – Reliable terminals
Internal wiring Securely crimped Securely wrapped TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

18 Construction – Double/Reinforced Insulation
Metal encased class II luminaire No contact between mounting surface and part with basic insulation only Double insulated wire Terminal block with a cover TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

19 Construction – Double/Reinforced Insulation
Metal encased class II luminaire No contact between accessible part and basic insulation Double insulated wire Insulating lining, sleeve Mechanical strength Electrical strength Thermal strength 1.Retained by positive means 2.Not be removed without being seriously damaged Humidity 48 hrs Insulation resistance & electric strength Thermal test T(wire)+20°C Aging T(wire)+20°C, 240 hrs, checked by electrical strength TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

20 Construction – Screws Torque test No damage No creep
TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

21 Construction – Screws Torque test
0,5 Nm for screws on cord anchorage bearing directly on cable or cord TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

22 Construction – Glands Torque test
TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

23 Construction – Mechanical Strength
Impact test TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

24 Construction – Mechanical Strength
Impact test - Live part shall not be accessible - Insulation shall not be impaired - No reduction on IP protection and classification - Removable/replaceable part can be removed/replaced without breakage TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

25 Construction – Mechanical Strength
Metal part enclosing live part Pressure test by test finger 30 N Metal part shall not touch live part No reduction on creepage distance and clearance TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

26 Construction – Mechanical Strength
All Suspended luminaires Loading test 4 x weight of luminaire 1 hrs No deformation on suspension system TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

27 Construction – Mechanical Strength
Rigid Suspended luminaires Torque test 2,5 Nm, 1 min Clockwise and anti-clockwise No rotation more than one revolution in both directions TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

28 Construction – Mechanical Strength
Rigid Suspension bracket (light duty) Loading 10 N, >=1,0 Nm, at free end 1 min No permanent displacement, deformation TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

29 Construction – Mechanical Strength
Track mounted luminaire Luminaire mass < max. load for track TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

30 Construction – Mechanical Strength
Adjusting device No twisting over 360 TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

31 Construction – Mechanical Strength
Flexing test Strands broken < 50% Insulation resistance & electric strength TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

32 Construction – Flammable Material
Glow‑wire test 650 C Spacing  30 mm No fiercely burning material TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

33 External Wiring Supply connection Supply cable & Plug
Adaptor for track Terminals TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

34 External Wiring Supply connection Connecting leads Appliance inlet
TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

35 External Wiring Type of cable 0,75 mm2 for ordinary luminaires;
1,0 mm2 for other luminaires TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

36 External Wiring Type of connection - Type X attachment
- Type Y attachment - Type Z attachment TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

37 External Wiring Cord anchorage
TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

38 External Wiring Cord anchorage
- Pull test (25 time, displacement <= 2mm) - Torque test TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

39 Internal Wiring Internal wiring directly connected to fixed wiring
Operating current >= 2 A Operating current < 2 A min. 0,5 mm2 min. 0,4 mm2 Insulation thickness: min. 0,6 mm (PVC or Rubber) Insulation thickness: min. 0,5 mm 1,5 mm2 for through wiring --

40 Internal Wiring Internal wiring connected to fixed wiring via current limiting device <= 2 A If current-carrying capacity and the mechanical properties are adequate Cross-sectional area min. may be less than 0,4 mm2 Insulation thickness may be less than 0,5 mm TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

41 External & Internal Wiring
Soldering Clamping terminal Spring terminal TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

42 External & Internal Wiring
Soldering Spring terminal Cold flow Bad electrical connection Clamping terminal TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

43 Earthing Accessible metal part, basic insulated
Non-accessible metal part, basic insulated, but in contact with supporting surface - Reliably connected to earthing terminal or earthing contact TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

44 Earthing TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

45 Earthing Location of earthing terminal Material of earthing terminal
Adjacent to mains terminal (type X, Y) Material of earthing terminal Brass or non-rusting material Bare contact surface TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

46 Earthing Cord for earthing
Green-yellow cord shall only be used for earthing connection Earthing make contact first Earthing detached later TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

47 Earthing Terminal blocks with integrated screwless earthing contacts
TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

48 Earthing Terminal blocks with integrated screwless earthing contacts
Pull test 20 N – terminal block shall be in place Pull test 50 N – applies only to earthing contact – no damage, no loosen on earthing contact Earthing contact – supporting plate < 0,05 ohm TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

49 Earthing Terminal blocks with integrated screwless earthing contacts
Voltage drop test Resistance < 0,05 ohm TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

50 Protection against electrical shock
Live parts not accessible when luminaire installed and wired as in normal use or during lamp/starter replacement - Wall-mounted luminaires: within arm reach, no access to basic insulated parts by means of a Ø 50 mm probe TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

51 Protection against electrical shock
Basis insulated parts of Class II luminaires to be regarded as live parts TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

52 Protection against electrical shock
No basic insulated components on outside of luminaire Luminaires incorporating a capacitor >0,5μF must be provided with a discharge device TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

53 Resistance to dust and moisture
Dust Test (IP#X) TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

54 Resistance to dust and moisture
Dust Test (IP#X) Solid-object-proof (IP2X) Solid-object-proof (IP3X or IP4X) Dust-proof (IP5X) Dust-tight proof (IP6X) TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

55 Resistance to dust and moisture
IP Test (IPX#) Drip-proof (IPX1) Drip-proof (IPX2) TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

56 Resistance to dust and moisture
IP Test (IPX#) Rain-proof (IPX3) and splash-proof (IPX4) TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

57 Resistance to dust and moisture
IP Test (IPX#) Jet-proof (IPX5) and powerful water jet-proof (IPX6) IP X5 15 min / distance = 3 m / 12,5 l/min ± 5 % (30 kN/m2) IP X6 3 min / distance = 3 m / 100 l/min ± 5 % (100 kN/m2) TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

58 Resistance to dust and moisture
IP Test (IPX#) Watertight (IPX7) 30 min in water / 150 mm of water above the top of the speciment and the lowest portion is subjected to at least 1 m head of water Pressure watertight (IPX8) 30 min in water / water pressure 1,3 x pressure which corresponds to the rated maximum immersion depth TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

59 Resistance to dust and moisture
Humidity test R.H. 91% to 95 % 10 ºC – 30 ºC 48 hrs TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

60 Insulation Resistance
Class I luminaire: 2 Mohm Class II luminaire: Basic/Supplementary insulation: 2 Mohm Double/Reinforced insulation: 4 Mohm Class III luminaire: 1 Mohm

61 Electric Strength Class I luminaire: 2U + 1000 V Class II luminaire:
Basic/Supplementary insulation: 2U V Double/Reinforced insulation: 4U V Class III luminaire: 500 V

62 Creepage distance & Clearances
Live Parts of different polarity Live Parts  Adjacent Metal Parts Live Parts  Body or Housing Live Parts  Mounting Surface TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

63 Creepage distance & Clearances
TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

64 Endurance and Thermal test
Endurance  7 or 10 Days Thermal Test  Normal operation Thermal Test  Abnormal operation Thermal Test on luminaires classified for mounting on normally flammable surfaces Thermal Test on thermalplastic luminaires TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

65 Resistance to heat, fire and tracking
Ball Pressure Test Needle Flame Test TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

66 Resistance to heat, fire and tracking
Glow-wire Test 650 ºC Tracking Test on IP>20 Luminaire TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

67 Routine test by Manufacturer
Visual check Function test Earth continuity (earthing resistance: 0,05ohm) Electric strength or insulation resistance (for metal encased) Polarity (for Class I luminaire) TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

68 Example I Nonconformity acording to section 3 HRN EN (Marking): 3.2 - HRN EN : Marking on luminaries The following information shall be distinctly and durably marked on the luminaire: a) Marking to be observed when replacing lamps or other replaceable components, shall be visible on the outside of the luminaire (except the mounting side) or behind a cover which is removed during lamp or other component replacement and with the lamp removed :Regarding to clauses 3.2.8, , , , , i ). b) Marking to be observed during installation shall be visible during installation on the outside of the luminaire or behind a cover or part which is removed during installation Regarding to clauses 3.2.1, 3.2.2, 3.2.3, 3.2.4, 3.2.5, 3.2.6, 3.2.7, 3.2.9, i ). c) Marking to be observed after installation shall be visible with the luminaire assembled and installed as for normal use and with the lamp in place (regarding to clause and ).

69 Example I 3.3 - HRN EN 60598-1: Additional information
In addition to the above marking, all details which are necessary to ensure proper installation, use and maintenance shall be given either on the luminaire, semi-luminaire or on built-in ballasts or in the manufacturer's instructions provided with the luminaire.Written instructions related to safety shall be in a language which is acceptable in the country in which the equipment is to be installed.. 3.4 - HRN EN : Test of marking Compliance with the requirements is checked by inspection and by the following test: The durability of the marking is checked by trying to remove it by rubbing lightly for 15 s with a piece of cloth soaked with water and, after drying, for a further 15 s with a piece of cloth soaked with petroleum spirit. TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

70 Example I HRN EN : Mark of origin - Marks exist, but the text which must explain their meaning isn’t on Croatian language – not i compliance with 3.3 (red color ) HRN EN : Maker's model number or type reference. Marks exist, but the text which must explain their meaning isn’t on Croatian language – not i compliance with 3.3 (red color ) TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

71 Example I 3.3 i HRN EN : A wiring diagram, except where the luminaire is suitable for direct connection to the mains supply. Wiring diagram is directing to wrong picture. (Red coloured) TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

72 Example II Remark:Portable luminaries for children HRN EN ) . Purpose of Portable luminaries (Luminaries that in normal use can be moved from one place to another while connected to the suply) for children is to provide a safety level of use for children younger than 14 years, which are not under supervision. Therefore must present higher level of security than safety level provided for a portable general luminarie purpose HRN EN ). Portable luminaries which are shaped or decorated like a toy (example: 3D animal, cartoon caracter, car models) must comply to requirements of standard HRN EN ) TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

73 Example II 3.2.2 i HRN EN : Rated voltage in volts exist, but symbol of type of supplied voltage not existing. For AC supply must be marked with sign nr iz norme IEC 2. Marking label with required informations dont comply testng according to 3.4 because it can be easily unstick TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

74 Example II 3.3 i HRN EN : Instructions that contain warnings regarding to safety must be written on Croatian language. For luminaries with Y type attachment: must contain warning ‘’method of attachment of the cable or cord such that any replacement can only be made by the manufacturer, his service agent or similarly qualified person’’. TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

75 Example II CE sign is not correct shape. Red markings show diferences between defined shape of sign nad CE sign wich is marked. Diferent components of CE sign must have same vertical dimension, not smaller than 5 mm TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.

76 Example II Incompliances to item 10.6 of standard HRN EN and section 4 standard HRN EN (Design): Portable luminaries for children shall have adequate stability Compliance shall be checked by placing the luminarie in the most unfavourable position of normal use, on a plane inclined at an angle of 15 ' to the horisontal, the surface of the olane being such that the luminarie dose not slide. The luminarie shall not overturn Flexible neck of luminarie is possible to set to position of difference angle 180 ° between diferent parts . On picture 5 5 is iluminant with neck bend to final position to the base. In that position luminarie is overturned at angle of 6 °.

77 Example II Sl. 6 Sl. 7 3.4 - HRN EN 60598-1: Test of marking
Compliance with the requirements of 3.2 and 3.3 is checked by inspection and by the following test: The durability of the marking is checked by trying to remove it by rubbing lightly for 15 s with a piece of cloth soaked with water and, after drying, for a further 15 s with a piece of cloth soaked with petroleum spirit and by inspection after the tests detailed in Section 12 have been completed. After the test, the marking shall be legible, marking labels shall not be easily removable and they shall show no curling. TAIEX Workshop on Safety Tests for Electrical Products; Cairo, Egypt, 3-4 December 2014.


Download ppt "Workshop on Safety Tests for Electrical Products Cairo, Egypt 3 – 4 December 2014 Performance tests for electrical lamps, LED lamps and electrical lanterns."