2 Team Introductions NameRoleMajor Brett BillingsTeam LeaderIndustrial Engineer Nick GrecoLead EngineerMechanical Engineer Ashley WaldronScribeMechanical Engineer Claire KobalEDGE MasterMechanical Engineer Jacob GardnerMechanical Engineer Ron JimboElectrical Engineer Ryan SeligElectrical Engineer

3 Agenda Problem Statement and Deliverables Project Background Customer Needs Engineering Requirements House of Quality Project Timeline Team Norms and Values

4 Current Product Old machine Motor recently died Oil splatter Senior Design 2012-2013 Created the displacement control mechanism for the vibration apparatus

5 Problem Statement: Project 14471 Cooper Crouse-Hinds Industries is a leader in the manufacturing of luminaires, an encased lighting system, for hazardous locations. These luminaires are placed in environments in which they are subject to harsh vibrational disturbances. Luminaires must meet the testing standards set in UL 844, which include vibration RPM and displacement, apparatus setup, and test duration. The company is currently using an outdated testing apparatus and would like to incorporate improvements into the new design. This project is a continuation of P13471 which started the process and has already built the eccentric drive mechanism. The new design still requires a frame, motor, and control system.

6 Background Information Luminaire A lighting fixture that could be exposed to hazardous conditions UL 844: Test fixture must: Vibrate luminaire at 2000 cycles/min Total displacement of 1/32” Operate for 35 hours

7 Project Deliverables Completed frame Appropriate motor selection and implementation Speed Control Alternatives Visual display Speed of motor Displacement Documentation User Manual Maintenance Manual Test data verifying the operation of the apparatus

8 Stakeholders Primary Customer: Joe Manahan Cooper Crouse-Hinds Dr. Varela Team 14471 Lab Technicians Secondary Customer: Companies who purchase luminaires from Cooper Crouse-Hinds RIT

9 Customers Needs RequirementsImportance Adherence to UL 844 standard5 Apparatus is safe5 Motor must be compatible with available voltage5 Ability to test multiple configurations3 Easy to use3 Easy to maintain2 Visually display test information/feedback to operator3 Ability to test a range of luminaire weights4 Cost under $4,0003 Long service life4 Similar dimensions to existing machine1

10 Engineering Requirements NumberRequirement Raw Score Units Ideal Measure 1 Displacement of luminaire69in1/32 2 Vibration of luminaire69cycles/min2000 3 Duration of vibration test69hours35 4 Isolate motor from oil spills45BinaryYes 5 Maintenance Documentation44Survey (easy to follow)80% 6 Mount pendant configuration35BinaryYes 7 Operation Documentation33Survey (easy to follow)80% 8 Machine won't operate if crankshaft enclosure is open25BinaryYes 9 Completely stop machine with Emergency Stop25seconds< 10 10 Maximum voltage of Motor25V AC240 11 Minimize number of operators21people2 12 Max weight of mounted luminaire20lbs> 150 13 Visually display settings and status of test18BinaryYes 14 Steps to set up16steps< 10 15 Setup Time16seconds< 120 16 Low Sound15dBA< 85 17 Minimize pinch points15Count< 3 18 Total materials cost15$< 4,000 19 Mount stanchion configuration7BinaryYes 20 Mount yoke configuration7BinaryYes 21 Mount trunnion configuration7BinaryYes 22 Machine footprint5in 2 < 34X48

11 Engineering Requirement Pareto

12 House of Quality Engineering Metrics Customer Requirements Customer Weights Displacement of luminaire Vibration of luminaire Duration of vibration test Low sound Machine won't operate if moving parts are exposed Completely stop machine with Emergency Stop Minimize pinch points Minimize number of operators Voltage of motor Mount pendant configuration Mount stanchion configuration Mount yoke configuration Mount trunnion configuration Visually display settings and status of test Operation documentation Steps required for Set-up Isolate motor from oil spills Maintenance documentation Max weight of mounted luminaire Total materials cost Time to Set up Machine footprint Adherance to UL844 testing standard5555 Apparatus is safe5 3553 3 1 Motor must be compatible with available voltage5 5 33 Ability to test multiple configurations3555 5111 Easy to use3 5 133 1 3 Easy to maintain2 3 1 53 Visually display test information/feedback to operator3333 511 1 1 Ability to test a range of luminaire weights4555 5111 5 Cost under $40003 5 Long service life4 1153 1 Similar dimensions to existing machine1 5 Technical Targets (Specifications) 1/32 in. 2000 cycles/min 35 hours < 85 dBA yes < 10 seconds < 3 ≤ 2 < 240 V AC Yes 80% via survey (easy to follow) < 10 steps Yes 80% via survey (easy to follow) > 150 lbs < $4000 < 120 seconds < 34X48 in 2 Raw score 69 1525 15212535 777 1833164544201516 5 Relative Weight 11% 2%4% 2%3%4%6%1% 3%5%3%7% 3%2%3%1%

13 Project Timeline

14 Next Phase Schedule

15 Team Norms and Values Behavior: Act professionally Don’t be condescending No yelling Keep an open mind Take responsibility Balance of work loads: Communicate Action items list Strengths: Take preferences into account Help other members learn Communication: Google groups Weekly meetings Urgent: text/call Decisions: Consider/consult expert No important decisions made alone Final decisions: consensus Conflict: One-on-one Take it to the group Take it to Advisor