Presentation is loading. Please wait.

Presentation is loading. Please wait.

Measurements of low mass e + e - pairs in p+p and Au+Au collisions with the HBD upgrade of the PHENIX detector Mihael Makek Weizmann Institute of Science.

Similar presentations


Presentation on theme: "Measurements of low mass e + e - pairs in p+p and Au+Au collisions with the HBD upgrade of the PHENIX detector Mihael Makek Weizmann Institute of Science."— Presentation transcript:

1 Measurements of low mass e + e - pairs in p+p and Au+Au collisions with the HBD upgrade of the PHENIX detector Mihael Makek Weizmann Institute of Science for the PHENIX Collaboration HP2010, Eilat, Israel

2 Low mass dileptons The Hadron Blind Detector Status of the dielectron analysis Conclusion and outlook Outline: 3/16/20162M. Makek, HP2010

3  Dileptons interact only electromagnetically  undisturbed path from the interaction region to the detectors  Probes for chiral symmetry restoration and in-medium modification of the low mass vector mesons  Results* from RHIC Run-4: yield in m ee = 0.15 - 0.75 GeV/c 2 larger by a factor 4.7 +/- 0.4(stat.) +/- 1.5(syst.) +/- 0.9(model) compared to the expected hadronic contribution  S/B in this mass region is 1/200  combinatorial background should be reduced! Low mass dileptons 3/16/20163 *Phys.Rev.C81, 034911 (2010) M. Makek, HP2010

4  The main sources of the combinatorinal background are from: π 0      e + e - π 0   e + e -  The magnetic field bends e + e - in opposite directions, one of them can go out of acceptance or can spiral in the magnetic field not reaching the tracking detectors Low mass dileptons 3/16/20164 ~12 m e+e+ e+e+ e-e- e-e- M. Makek, HP2010 comb. backg. pair

5 How to reduce the combinatorial background?  e + e - from π 0 Dalitz decays and conversion have a small opening angle (close pairs) unlike the pairs produced by resonance decays (open pairs)  Preserve the opening angle  create magnetic field-free region  Distinguish between the single electron hit from an open pair and the double electron hit from a closed (background) pair  the task of the HBD! Low mass dileptons 3/16/20165M. Makek, HP2010   π0π0 

6 The HBD is a windowless Cherenkov detector CF 4 radiator gas and active gas. L rad =50 cm triple GEMs for signal multiplication CsI photocathode proximity focus configuration hexagonal pad readout (pad side a = 1.55 cm) total radiation length: ~4.4% 0.9% (vessel) + 0.5% (CF 4 ) + ~3% (backplane) The HBD – the basic concept 63/16/2016M. Makek, HP2010 Cherenkov blobs e+e+ e-e-  p air opening angle B≈0 1.21 m NIM A 546 (2005) 466-480, NIM A 523 (2004) 345-354 0.65 m

7 Electron signals are relatively weak and rare (compared to hadrons) Hadron blindness: The HBD – hadron blindness 73/16/2016M. Makek, HP2010 a.Cherenkov light is formed only by e + or e -, threshold for  is 4 GeV/c b.the detector is operated in reverse bias mode to repel the ionization charge from dE/dx CsI (350 nm) primary ionization from dE/dx El. Field photo electron mesh GEMs pads

8 Run-9: p+p collisions at 500 GeV:  Recorded 0.01 nb -1 p+p collisions at 200 GeV Recorded 0.02 nb -1 Run-10: Au+Au collisions at 200 GeV:  Recorded 1.3 (1.1) nb -1 or 8.2B (7.0B) events in +/-30 (+/-20) cm vertex (5x data than in Run-4) Au+Au collisions at 62.4 GeV:  Recorded 0.1 nb -1 or 700M events in +/- 30 cm vertex Au+Au collisions at 39 GeV:  Recorded 0.04 nb -1 or 250M events Measured data sets 83/16/2016M. Makek, HP2010 PHENIX Integrated luminosity in Run-10 200 GeV

9 The HBD performance: position resolution 93/16/2016M. Makek, HP2010 Position resolution: CA track projection( ,Z) – HBD cluster position( ,Z) Run 9, p+p For single pad hits: 2a/sqrt(12) ~ 1 cm ~1/p const For electrons (~3 pads):   = 8 mrad (0.5 cm)  intrinsic resolution)   = 1.05 cm ( 0.5 cm intrinsic, ~1 cm vertex )  (rad)  (cm)

10 The HBD performance: electron-hadron separation 103/16/2016M. Makek, HP2010 HBD charge: hadrons in forward vs. reverse bias Run 9, p+p HBD charge: electrons vs. hadrons Good electron-hadron separation! 20 pe

11 The HBD performance: single vs. double hit recognition 113/16/2016M. Makek, HP2010 Run 9, p+p HBD charge – single hitHBD charge – double hit Fully reconstructed  0 Dalitz pairs (m < 150 MeV/c 2 ) in the central arms. Matched to HBD into two separate clusters (open pairs) or one single cluster (close pairs) Single electron charge peaks at 20 pe Double electron charge peaks at ~40 pe  Good single to double separation, important for rejection of the combinatorial background

12 The average number of photo- electrons N pe in a Cherenkov counter: with:   (average Cherenkov threshold in the sensitive bandwidth of the detector)  bandwidth: 6.2 eV (CsI photocathode threshold) - 11.5 eV (CF 4 cut-off) The HBD performance: figure of merit N 0 and single electron detection efficiency 123/16/2016M. Makek, HP2010 N 0 ideal value795 cm -1 Optical transparency of mesh89 % Optical transparency of photocathode81 % Radiator gas transparency92 % Transport efficiency80 % Reverse bias and pad threshold90 % N pe measured20 N 0 measured value330 cm -1 The high photoelectron yield  excellent single electron detection efficiency:  Single electron efficiency using a sample of open Dalitz decays:  ~ 90 %  Single electron efficiency derived from the J/  region:  = 90.6  9.9 % 330 cm -1 The detector is kept almost H 2 O and O 2 free!

13 HBD occupancy grows due to scintillation (central events > 95 %) The average charge per cell subtracted (event-by-event basis) Occupancy reduced to ~30 % in the central events Efficiency estimate using embedding of MC with HBD data: 80% in the most central – 90% in the peripheral events The HBD performance: subtraction of the scintillation background (in Au+Au collisions) M. Makek, HP20103/16/201613 HBD module before subtraction: HBD module after subtraction: Run 10, Au+Au

14 143/16/2016M. Makek, HP2010 Estimate from Run-9 p+p: StepBckg. reduction factor 1 matching to HBD7.1  2.2 2 double hit cut close hit cut 6.5 3 single pad cluster cut2 Run 9, p+p Pairs in Central Arms Pairs matched to HBD Pairs after HBD reject. Status of the dielectron analysis (m ee > 0.15 GeV/c 2 )

15 The HBD detector has been developed and installed It was successfully operated in the PHENIX set-up in Run-9 (p+p) and Run-10 (Au+Au) The data shows:  good position resolution  excellent electron detection efficiency  good separation between electrons and hadrons  good separation of single and double electron hits  successful handling of scintillation background Analysis of Run-10 Au+Au data in progress:  62.4 GeV data set produced  200 GeV data set production under way  Physics coming soon! Conclusion and Outlook 153/16/2016M. Makek, HP2010

16 BACKUP slides 163/16/2016M. Makek, HP2010

17 PHENIX detector 173/16/2016M. Makek, HP2010 Detector  Field PH Central Arms+/- 0.35360°up to 1.15 Tm Inner and outer magnet coils producing field-free region for r < 55 cm

18 HBD design parameters 183/16/2016M. Makek, HP2010

19 Scintillation Ionization HBD gain determination 193/16/2016M. Makek, HP2010 Forward Bias Reverse Bias Zoom  Gain determination: Fit scintillation component with an exp fctn: 1/slope = G. = avrg no. of scintillation photons in a fired pad)  In p+p collisions  1  In Au+Au collisions, assuming the no. of scintillation photons per pad follows a Poisson distribution:

20 HBD in reverse bias mode 203/16/2016M. Makek, HP2010 Operating Point Electron vs. hadron detection efficiecy:Remaining hadron signal: The operating point chosen to minimize the hadron signal while keeping the optimal electron detection efficiency The remaining hadron signal comes from the collection of dE/dx ionization in the thin layer (100 microns) above the first GEM and from the ioniozation in the first transfer gap This signal is much lower than electron signal (1/20)! Remaning signal


Download ppt "Measurements of low mass e + e - pairs in p+p and Au+Au collisions with the HBD upgrade of the PHENIX detector Mihael Makek Weizmann Institute of Science."

Similar presentations


Ads by Google